Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Energy was posted on January 28, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Multi -Roof Replacement Project

Closed
Federal
Submission Closed
Solicitation #
RFP26-021R

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236220
New
SLED
Repair Auto Maintenance Bldg 575
Solicitation # N40085-27-R-9000
Solicitation N40085-27-R-9000 involves the repair and modernization of the Auto Maintenance Facility, Building 575, at MCB Camp Lejeune, North Carolina. The scope of work is comprehensive, including selective demolition, building envelope repairs, new roofing, exterior wall systems, and interior reconfiguration. Technical upgrades include new HVAC systems, exhaust extraction, compressed air systems, a full NFPA-compliant fire suppression system, and the replacement of electrical distribution, lighting, and low-voltage systems. Additionally, the project covers site improvements such as paving, drainage upgrades, water and sanitary system repairs, and hazardous materials abatement. The estimated cost is between $10 million and $25 million, with a completion period of 730 days. The contract is awarded based on the lowest price, with pricing required for building renovation and paving removal and replacement. Proposals are due by December 2, 2026. Bonding requirements include a payment bond for proposals of $35,000 or more, and a bid bond, payment bond, and performance bond for those $150,000 or more. Key personnel requirements specify that the Quality Control Manager must be a stand-alone position, though the Superintendent and Site Safety and Health Officer roles may be combined. The project is subject to the Davis-Bacon Act and must comply with ADA accessibility standards and specific cybersecurity requirements for facility-related control systems. There is no set-aside status specified for this solicitation.
Bristol Alliance of Companies

POSTED

about 3 hours ago

DEADLINE

in 6 days
NAICS: 236220
New
SLED
DB Repair Fire Sprinkler Deficiencies, B290, PSNS
Solicitation # N4425527RB007
This is a Design-Build contract for the repair of fire sprinkler deficiencies at Building 290 and the adjoining covered loading dock platform, Building 719, located at Naval Base Kitsap in Bremerton, Washington. The contractor is responsible for producing final design documentation per FC 1-300-09N Navy and Marine Corps Design Procedures and providing all necessary construction materials, labor, supervision, and performance testing to create a complete and usable system. Key technical objectives include resolving Risk Assessment Code Level 4 (RAC-4) deficiencies at the loading dock platform, ensuring sprinkler control valves in basement elevator pits are locked open and monitored by the fire alarm system, and installing missing backflow preventers on the north and south 6-inch diameter wet pipe sprinkler system risers. The project is an 8(a) Multiple Award Construction Contract (MACC) with a Firm Fixed-Price structure and an estimated magnitude between $1 million and $5 million. The period of performance is 440 days from the award of the task order. Award is based on price and MACC past performance, with the government evaluating the most advantageous proposal. The contractor must adhere to strict safety and quality standards, including EM 385-1-1 and the maintenance of a Contractor Quality Control (CQC) program. Required deliverables include final design documentation and as-built record drawings.
Bristol Alliance of Companies

POSTED

about 3 hours ago

DEADLINE

in 6 days
NAICS: 236220
New
SLED
Modify Transfer Facility NBK Bangor
Solicitation # N44255-25-R-1502
Solicitation N44255-25-R-1502 is a design-build project for the renovation and modernization of Facility #6594 (Transfer Facility) at Naval Base Kitsap Bangor, Washington. The project is estimated to have a magnitude between $10 million and $25 million. The scope involves a critical two-phase renovation that requires the facility to remain operational and mission-capable between phases, necessitating strict scheduling, specialized security protocols, and multiple mobilization and demobilization cycles. Phase 1 includes all work not assigned to Phase 2, and the design for both phases must be completed and approved during Phase 1. Phase 2 focuses on the installation of new building equipment, including the replacement of a 40-ton bridge crane and the installation of a prefabricated paint booth in the High Bay area. Additional requirements include the construction of a 400 square foot addition for forklift battery charging, HVAC and electrical upgrades, and compliance with cybersecurity (ATO) and UMCS continuity standards. The contract is awarded based on price only with MACC past performance. The period of performance requires work to commence within 15 calendar days of award, with the base bid (CLIN 0001) due for completion within 360 calendar days and an option (CLIN 0002) due within 1082 calendar days. Proposals must be submitted via the PIEE portal by December 7, 2026, at 11:00 am local time. Key requirements include the provision of bid and performance bonds, adherence to USACE EM 385-1-1 safety standards, and compliance with the Davis-Bacon Act. There is no set-aside status specified for this solicitation.
Bristol Alliance of Companies

POSTED

about 3 hours ago

DEADLINE

in 8 days
NAICS: 236220
New
Federal
Roof Replacement Mandatory Site Visit: 12/03/2026 @ 11 AM
Solicitation # 26-144
Solicitation 26-144 is for a full roof replacement of the 1963 LBJ building at the Atterbury Job Corps Center in Indiana, operated by Adams & Associates for the U.S. Department of Labor. The project is necessitated by persistent leaks and storm damage, including missing shingles and a damaged roof ridge cap. This is a single lump sum contract requiring a mandatory site visit on December 3, 2026, at 11 AM, with proposals due by December 14, 2026. The set-aside status is designated for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Award will be based on best value, with evaluation weights assigned to price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). The contractor must provide a one-year workmanship guarantee and a two-year manufacturer's product warranty. All work must comply with EPA, OSHA, and national, state, and local building codes, with Indiana regulations prevailing if more stringent. Requirements for submission include a typed proposal on company letterhead, a valid Indiana Contractor's License, insurance certificates naming Adams and Associates, Inc. as an additional insured, a completed Vendor Questionnaire, and a W9. Payment terms are Net 30.
Atterbury Job Corps – Adams & Associates

POSTED

about 3 hours ago

DEADLINE

in 17 days
NAICS: 236220
New
Federal
Site Visit (required) Replacement of existing damaged fire rated doors and frames-
Solicitation # 26-141
Solicitation 26-141 is for the removal and replacement of damaged fire-rated doors and frames at the Atterbury Job Corps Center cafeteria in Edinburgh, Indiana. The project requires the installation of new fire-rated doors while reusing existing push bars and closure systems. All work must comply with local, state, and federal building codes, as well as EPA and OSHA regulations. The contract is a single lump sum award with Net 30 payment terms and includes a one-year guarantee of workmanship. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Proposals are due by December 11, 2026, and must be submitted on official company letterhead with a detailed cost breakdown, a timeline for substantial completion, and a 90-day bid guarantee. A mandatory site visit on December 1, 2026, is required for bid consideration. Award will be based on Best Value, evaluated across price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Required documentation includes a W9, a completed vendor questionnaire, proof of a valid Indiana contractor's license, and certification of compliance with Davis-Bacon Act wage rate decisions. Contractors must also provide proof of automobile liability and workers compensation insurance, naming Adams and Associates, Inc. as an additional insured.
Atterbury Job Corps – Adams & Associates

POSTED

about 3 hours ago

DEADLINE

in 14 days

AI Contract Overview

Show more

This contract involves the complete removal and replacement of deteriorated roofing systems on multiple buildings at the Princeton Plasma Physics Laboratory, including the ESAT Building, PLT Power Building, C Site Pump House, and Rad Waste Handling Facility. The existing roofs have surpassed their useful life and suffer from severe water infiltration, damaged flashing, and metal coping issues, requiring urgent attention to prevent operational disruptions in critical laboratory functions. The contractor is responsible for providing all necessary materials, labor, supervision, and equipment, ensuring compliance with manufacturer specifications to deliver a high-quality, durable roofing system with a minimum 30-year warranty. The scope encompasses demolition of existing roofing materials, recycling of stone ballast, inspection and replacement of integrated roof components such as drains, gutters, and flashing, and installation of new roofing comprising layers of insulation, cover boards, and a 145-mil Carlisle Fleeceback EPDM membrane. Additional requirements include raising curbs and vents, adding expansion joints, installing new roof drains, and providing perimeter guardrails. Coordination with asbestos abatement efforts, protection and reinstallation of roof-mounted equipment, and power shutoff arrangements are also required. The project emphasizes maintaining structural integrity, energy efficiency with an R-30 insulation value, and compliance with safety standards. The scheduled response deadline for bids is February 24, 2026, and the work is to be performed in Princeton, New Jersey under the oversight of the DOE contractor organization.

General Info

Roof replacement at Princeton Plasma Physics Lab buildings with durable materials, 30-year warranty, bid deadline February 2026.

NAICS

236220 - Commercial and Institutional Building Construction

Place of Performance

Princeton, NJ, 08543, USA

Set-Aside

NONE

Documents

9
PDF, High priority: read this first2 pages · rfp
High
PDF, High priority: read this first1 page · rfp
High
PDF, High priority: read this first1 page · instructions
High
PDF, High priority: read this first1 page · sow
High
PDF, High priority: read this first1 page · wage-determination
High
PDF, High priority: read this first30 pages · sow
High
PDF, Low priority1 page · acknowledgment-form
Low
PDF, Low priority1 page · contract-document
Low
PDF, Low priority1 page · other
Low

Read all 9 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • DB Major M&R Sector Lake MIchigan, INTERNALOpen now, due in 21 days
  • Building 262 Renovations FLETC GlyncoOpen now, due in 6 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

1 update
PhaseClosed
Posted

Solicitation

Notice updated

Response deadline changed from Feb 24, 2026 to Feb 27, 2026. The notice description changed.

Response Deadline

Deadline has passed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Energy → Princeton Labor - DOE Contractor
Contacts1 person available
OfficePrinceton, NJ, 08540, USA

Full Description

Show more

There are several existing roofs (C50 ESAT Building/C52 PLT Power Building/C60 C Site Pump
House/D45 Rad Waste Handling Facility) which are past their useful life requiring costly
maintenance to upkeep. Severe water infiltration occurs regularly at failing joints, punctures,
and flashing. Portions of existing metal coping have pulled away during storm events causing
large sections of membrane to separate from the substrate. A catastrophic failure to one of
these roofs would negatively impact the ability to conduct the top priority experimental
operations in the Laboratory.
1.2. SCOPE
1.2.1. The Subcontractor shall provide all materials, labor, supervision, equipment, and expertise
required replace the noted roofs and specified components per the associated contract
documents. Construction scope includes the following:
1.2.1.1. Remove and replace existing built-up roofs at PPPL. Buildings include:
1.2.1.1.1. C50 – ESAT Building
1.2.1.1.2. C52 – PLT Power Building
1.2.1.1.3. C60 – C Site Pump House
1.2.1.1.4. D45 – Rad Waste Handling Facility
1.2.1.2. Demolition including removal of existing membrane, cover board, insulation, metal trim,
flashing, coping and any other miscellaneous roofing material accessories.
1.2.1.3. Remove and recycle stone ballast on ballasted roofs. Recycle documentation to be
provided to PPPL.
1.2.1.4. Additional integrated roof elements shall be inspected and replaced as specified within
this SOW. Elements include: wood blocking, roof drains, gutters, scuppers, downspouts,
and metal/concrete roof panels.
1.2.1.5. Abandoned equipment shall be removed to a point that does not affect new roof
installation. Any equipment that should be temporarily relocated so roof replacement
work can be completed shall be the responsibility of the roofing contractor.
1.2.1.6. Contractor to furnish and install 2 layers of 2.6” ISO.
1.2.1.7. Contractor to furnish and install ½” HD coverboard mechanically fastened.
1.2.1.8. Contractor to furnish and install 145 mil Carlisle Fleeceback EPDM, black in color adhered
to coverboard.
1.2.1.9. Contractor to furnish and install counter flashing and copings, expansion joints and other
roofing components as required for manufacturer’s warranty.
Page 3 of 21
1.2.1.10. The new roof system shall be comprised of the following materials: EPDM membrane,
cover board, and insulation.
1.2.1.10.1. Meets a minimum insulating value of R-30 average. Modifications to the existing
building envelope are required to accommodate additional insulation.
1.2.1.10.2. Flexible walkway pads shall be provided to all operating equipment/drain locations
and as necessary to meet manufacturer’s requirements.
1.2.1.10.3. All materials shall be furnished by Carlisle Syntec Systems and shall meet all
manufacturer specifications to obtain a minimum manufacturer system warranty of
30 years along with a 2-year installers warranty. The warranty coverage shall
include incidental membrane punctures, damage from hail and a minimum of 72-
mph peak gust wind speeds.
1.2.1.11. Roof perimeter guardrails shall be provided on all roofs. See attached guardrail cut sheet
for details.
1.2.1.12. New and higher curbs as required due to the new roof installation work.
1.2.1.13. Contractor to build up existing roof vents as required due to the new roof work.
1.2.1.14. Expansion joint to be raised up to account for new roof insulation height for the ESAT
building roof.
1.2.1.15. Contractor to add a new roof drain at the Northwest section of the ESAT building roof.
1.2.1.16. Contractor to replace all existing roof scuppers with new.
1.2.1.17. Contractor to replace all existing roof drains with new.
1.2.1.18. Contractor to provide minimum of 12” overlap between the existing adjacent roof
membrane system and provide written confirmation the systems are compatible.
1.2.1.19. Contractor to temporary relocate and reinstall any fall protection anchor systems
identified on roof sections.
1.2.1.20. Contractor to install secondary drainage per code in addition to existing drains for the PLT
building roof.
1.2.1.21. If necessary, existing asbestos elements shall be mitigated by PPPL. Subcontractor to
assist the abatement contractor to bring the sealed roofing material down from roof area
to grade with lift equipment. Coordination of this work shall be completed in concert with
all other construction activities. The subcontractor to follow directly after PPPL
abatement contractor to install new roofing system. The construction subcontractor shall
be responsible to coordinate all work with PPPL.
1.2.1.22. Any and all equipment that requires power disconnect has to be coordinated with PPPL a
minimum of 72 hours prior. All equipment that will be out of service shall be minimized.
1.2.1.23. All roof fans and equipment are to be salvaged, protected, and reinstalled.



THERE ARE (5) COVER LETTER SECTIONS TO THE RFP.  THERE ARE FILES ATTACHED TO EACH COVER LETTER.  TO VIEW THE ATTACHMENTS YOU MUST



(1) FIRST DOWNLOAD EACH COVER LETTER SECTION TO YOUR DESKTOP. 


(2) AFTER DOWNLOADING EACH COVER LETTER--REOPENED EACH ONE (ON YOUR DESKTOP)


YOU SHOULD BE ABLE TO SEE THE ATTACHED FILES ON THE RIGHT HAND SIDE OF THE COMPUTER SCREEN.   BE SURE TO UTILIZE ADOBE ACROBAT SOFTWARE TO VIEW THE PDF FILES

More opportunities from Department Of Energy → Princeton Labor - DOE Contractor

Same awarding agency

NAICS: 238160
Federal
RF Roof Replacement Project
Solicitation # RFP27-005JR
The Princeton Plasma Physics Laboratory is soliciting proposals for the RF Roof Replacement Project to replace the roofing systems on the C40 RF Building and C41 CS Building in Princeton, New Jersey. The scope of work includes the demolition of existing built-up roofs and membranes, the installation of new roofing systems and accessories, and the replacement of drains and scuppers. The project also involves installing thermally broken galvanized steel roof hatch units and smoke vent units. This effort is being conducted as a Full & Open Competition under NAICS 238160, with the intent to award a Firm Fixed-Price Subcontract. Proposals are due by December 10, 2026, and must be submitted electronically to Procurement Specialist Jimmy Russell. The evaluation will follow the Lowest-Price Technically Acceptable (LPTA) standard, focusing on responsiveness, technical capability, responsibility, and price. Key requirements for offerors include the submission of a bid bond for 20% of the total proposed price, a progress schedule based on a January 5, 2027, notice-to-proceed date, and evidence of past performance on at least two to three similar projects completed within the last ten years. Additionally, the contractor must comply with the Construction Wage Rate Requirements Statute and provide both performance and payment bonds prior to the start of work.
Roofing Contractors

POSTED

17 days ago

DEADLINE

in 14 days
View Details

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS