Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

Multi TD Talbert Marsh Deteriorated Pole Replacement Project, (Notification of Lake or Streambed Alteration, No. EPIMS-ORA-63917-R5)

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The California Department of Fish and Wildlife has entered into Lake and Streambed Alteration Agreement EPIMS-ORA-63917-R5 with Southern California Edison Company for the Multi TD Talbert Marsh Deteriorated Pole Replacement Project in Costa Mesa, California. The project involves the removal and replacement of eleven deteriorated wood utility poles, one H-frame wood structure, and two associated 3-eyed rod screw anchors. To facilitate these installations, three cranes will be utilized across three designated staging pads. The project is categorically exempt under California Environmental Quality Act guidelines as it involves minor alterations to existing public utility structures with negligible expansion. The project will result in temporary impacts to 0.448 acres of vegetation, including Quailbush Scrub, Menzies Golden Bush Scrub, Mulefat Thickets, and Arroyo Willow Thickets. Mitigation efforts include crown reduction of less than 60 percent for eleven arroyo willow trees and the restoration of impacted areas through the salvage and replacement of the top six inches of topsoil. The agreement mandates the use of qualified biological monitors and requires the submission of a Final Construction Report within 60 days of project completion. The agreement is scheduled to expire on March 4, 2031, and grants the Department of Fish and Wildlife the authority to inspect project areas and revoke the agreement if non-compliance occurs.

General Info

Southern California Edison replaces poles and structures in Talbert Marsh with temporary habitat disturbance and post-construction restoration.

Agency

California → Fish and Wildlife, Region 5 - South Coast, San Diego

NAICS

237130 - Power and Communication Line and Related Structures ConstructionView NAICS

Place of Performance

Costa Mesa, CA

Set-Aside

NONE

Documents

(2)

Notice of Exemption - Multi TD Talbert Marsh Pole Replacement Project

PDFnotice-of-exemption

Streambed Alteration Agreement EPIMS-ORA-63917-R5 Multi TD Talbert Marsh Pole Replacement

PDFcontract-document

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Fish and Wildlife, Region 5 - South Coast, San Diego
Contacts2 people available
OfficeN/A
Organization / Agency
California → Fish and Wildlife, Region 5 - South Coast, San Diego
Office AddressN/A
Contacts
Dane St. GeorgeSenior Environmental Scientist (Specialist)
Victoria ParsonsSenior Manager

Full Description

Show more
The California Department of Fish and Wildlife (CDFW) has executed Lake and Streambed Alteration Agreement EPIMS Notification No. EPIMS-ORA-63917-R5, pursuant to section 1602 of the Fish and Game Code to Southern California Edison Company (SCE). The Project consists of removing and replacing eleven existing single utility deteriorated wood poles with eleven new single wood utility poles, removing and replacing one existing H-frame wood structure with one new H-frame wood structure, and removing and replacing two existing 3-eyed rod screw anchors with two 3-eyed rod screw anchors associated with the H-frame structure. Three cranes will be used to set new utility poles and the new H-frame wood structure. The Project activity’s total temporary impacts of 0.448-acre include vegetation trimming and crushing, staging, overland travel, excavation, and general work activities. The temporary impact area consists of Quailbush Scrub, Menzies’s Golden Bush Scrub, Mulefat Thickets, and Arroyo Willow Thickets. Tree trimming may occur on a total of eleven arroyo willow trees ranging from 8-24 inches diameter at breast height. Tree trimming will result in crown reduction of less than 60 percent on eleven arroyo willow trees. SCE will restore the 0.448 acre of temporary impacts on site by recontouring and replacing topsoils to pre-Project conditions.

Similar Contracts

Same NAICS industry code

NAICS: 237130
New
Kittrell Job Corps Center-12 Strand Fiber Optic Replacement- Bldg 2, Bldg 3, Bldg 4
Solicitation # kittrell-job-corps-center-12-strand-fiber-optic-replacement-bldg-2-bldg-3-bldg-4
Covenant Learning Solutions, operator of the Kittrell Job Corps Center in North Carolina, is soliciting sealed bids for the replacement of 12-strand aerial fiber optic cables and associated connectors between Buildings 2, 3, and 4. The contractor is responsible for providing all labor, materials, equipment, and supervision to install outdoor-rated fiber optic cable along existing aerial pathways and terminate them into existing network switches. A critical requirement of this project is that the existing network service must remain fully operational without interruption until the owner authorizes the final switch-over. The contractor must also provide a construction timeline for approval during a pre-construction meeting and adhere to standard work hours of 8:00 AM to 3:00 PM, Monday through Friday. The project requires strict adherence to industry standards, local codes, and manufacturer specifications regarding cable support and bend radius. Acceptance is contingent upon successful Optical Loss Testing, OTDR testing, continuity testing, and polarity verification, as well as the submission of a complete closeout package with as-built documentation. Bidders must hold a valid North Carolina General Contractor license and maintain all necessary Builder's Risk and Liability insurance. Proposals must be submitted via email to Rachelle Judkins by September 30, 2026, and must include a completed Mandatory Bid Document. Payment will be issued as a single lump sum upon project completion, provided all required purchasing documentation is submitted.
Covenant Learning Solutions operator of Kittrell Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in 8 days
View Details
NAICS: 237130
New
Federal
Sources Sought for the Recapitalization of the Navy’s High Voltage (230kV) Transmission Loop and all Ancillary Equipment at Naval Submarine Base Kings Bay, GA
Solicitation # N69450-26-R-PW20
The Department of Defense, through Navfacsyscom Southeast, is conducting a sources sought effort to identify qualified participants for the wholesale recapitalization and cybersecurity hardening of the 230kV high voltage transmission loop and all ancillary equipment at Naval Submarine Base Kings Bay, Georgia. This critical infrastructure project is essential for the nuclear deterrent mission and requires seamless integration with the Georgia Power Company (GPC) grid. The anticipated scope of work is a design-build effort including the relocation of the high power loop and crossing tower, replacement of conductors, installation of smart motor-operated disconnects and vacuum/SF6 circuit breakers, and the modernization of substation digital protective relays with encrypted SCADA telemetry. All work must comply with NERC CIP standards and DoD Unified Facilities Criteria for Industrial Control Systems. The estimated magnitude of the procurement is between $100 million and $250 million, with a projected period of performance of approximately 900 calendar days. Due to the proprietary nature of the utility provider's SCADA software and the requirement for specialized network access, the government is considering a sole-source procurement with GPC under FAR 6.103-1. However, interested parties under NAICS 237130 or 221122 may respond by October 6, 2026. Qualified respondents must demonstrate a single-project bonding capacity of $200 million, provide evidence of NERC CIP compliance, and ensure key personnel possess at least Tier 3/Secret security clearances. The resulting contract is expected to be a firm-fixed-price award.
Navfacsyscom Southeast

POSTED

about 18 hours ago

DEADLINE

in 15 days
View Details
NAICS: 237130
New
International
New Underground Electric Service System
Solicitation # NCC-CS-041053-NRFP
The National Capital Commission has issued a Negotiated Request for Proposals, solicitation number NCC-CS-041053-NRFP, for the installation of a new underground electric service system at Jacques Cartier Park North in Gatineau, Quebec. The project aims to provide a permanent, higher-capacity power supply to support major events, such as Winterlude, while reducing reliance on diesel generators. The scope is divided into two phases: Phase 1 focuses on core infrastructure and civil works near Laurier Street, including the installation of chambers CT-1 and CT-2 and utility work at the Maison du vélo. Phase 2 is an optional scope extending to south-east and north-east kiosks, including four pull manholes and connecting underground linear infrastructure. The contractor is responsible for removing existing electrical infrastructure, installing a new 600 V electrical entrance and low-voltage distribution, and ensuring the park is reinstated to its original condition with protection for significant trees. The project must be completed and the contractor demobilized by Winter 2027/2028. This solicitation is reserved for Canadian suppliers and requires bidders to hold specific RBQ licenses for civil and electrical work, as well as active accreditation from Hydro-Québec. Evaluation is conducted in three stages: a review of mandatory submission requirements, a technical evaluation including project methodology and experience, and a pricing evaluation worth 30 points of the total score. Award is based on the ranking of proponents from the combined technical and pricing scores. Selected contractors must provide performance and payment bonds each equal to 50 percent of the project value. All work must adhere to Hydro-Québec standards and CSA C22.1 and C22.2 specifications.
National Capital Commission

POSTED

1 day ago

DEADLINE

in 10 days
View Details
NAICS: 237130
New
SLED
Radio Tower & Building Tower, San Antonio DHQ - SAT
Solicitation # 15-470426753
The Texas Department of Transportation (TxDOT) is soliciting bids for a turnkey communications site project at the San Antonio DHQ in Bexar County, Texas. This State Let Building Contract involves the demolition of an existing 300ft tower and the design, fabrication, and installation of a new 350ft self-supporting tower, a 10x20 equipment shelter, a 30KW diesel generator, and a heavy hurricane fence. The scope includes all civil site work, power and data hookups, antenna systems, and the installation of Drake Lighting for FAA compliance. All technical drawings and design calculations must be sealed and signed by a Texas licensed engineer and adhere to ANSI/TIA/EIA-222H and AISI structural standards. Bids are due by November 3, 2026, at 12:00 PM CT and must be submitted via the Euna Procurement Portal. The contract will be awarded to the lowest responsive bidder. Required submission documents include a lump sum bid form, a bid bond of 20,000, a HUB subcontracting plan, and a signed E-Verify memorandum. The project has a contract duration of 365 days, and the agency will not disclose an estimated construction cost. Contractors must comply with the Davis-Bacon Act, Texas Government Code Chapter 2258 for prevailing wages, and TxDOT's third-party ethics and Buy Texas requirements. Payment is processed through TxDOT forms and requires the submission of an updated work progress schedule.
Texas Department Of Transportation

POSTED

3 days ago

DEADLINE

in about 1 month
View Details
NAICS: 237130
New
International
Fibre Optic Infrastructure Expansion 80 Avenue - 202A Street to 216 Street
Solicitation # 26-160
The Township of Langley is soliciting tenders for solicitation number 26-160, titled Fibre Optic Infrastructure Expansion 80 Avenue - 2020A Street to 216 Street. The primary scope of work involves the supply and installation of underground communication conduit infrastructure from 212 Street to 216 Street and the installation of fibre optic cabling from 202A Street to 216 Street along 80 Avenue. This includes the installation of approximately 800 meters of fibre optic duct via horizontal directional drilling, with pavement restoration required at entry and exit pit locations in accordance with the Township's Subdivision And Development Servicing Bylaw 2019 No: 5382. The project includes optional work to connect nearby traffic intersection cabinets to the new fibre optic trunk cable at seven specific locations along 80 Avenue, ranging from 202A Street to 216 Street. This optional scope encompasses the supply and installation of 12F SM fibre optic cable between FOSC vaults, wall mount patch panels, accessories, fusion splices, and cable testing. Contractors must adhere to the project Erosion Control plan for water discharge and follow the Township's Archaeological Chance Find Management Guidelines if any artifacts or remains are discovered. The response deadline for this solicitation is October 14, 2026.
Township of Langley

POSTED

3 days ago

DEADLINE

in 23 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS