This Solicitation opportunity from Department Of Defense was posted on May 8, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
N041 - HAYW 26-2011 Replace HVAC B122
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of Defense, through the W7MX Uspfo Activity Caang 144 contracting office at Fresno Air National Guard Base, California, is soliciting bids for a firm-fixed-price contract to replace HVAC infrastructure at the 144th Fighter Wing facility. The contract requires the removal of four existing HVAC units along with their associated ducting, electrical, and drain lines, followed by the installation of a new 40-ton HVAC system. The new system must meet stringent environmental operating parameters to support specific training equipment, maintaining temperatures between 59 to 78 degrees Fahrenheit and humidity ranges from 35% to 80% RH when operating, and broader temperature and humidity storage conditions. The project also involves replacing existing dust covers with custom roof adapters to properly interface with existing ductwork, while strictly using current building penetrations to comply with Intelligence Community Directive 705, thereby preserving the facility’s security integrity. All construction must conform to Unified Facilities Criteria 3-410-01. Bids must be submitted electronically through the PIEE solicitation module with a submission deadline of May 22, 2026. This opportunity is a total small business set-aside under NAICS code 238220, and offerors must certify their small business status accordingly. The solicitation references only one specific contractual provision, the bid guarantee requirement under FAR clause 52.228-1. Although the contract documentation does not provide detailed pricing data, evaluation factors, delivery schedules, or payment office details, the scope and compliance requirements emphasize secure, quality HVAC installation adhering to federal standards. Inspection and acceptance are expected to take place at the Fresno Air National Guard Base, and all work must use existing access points to avoid compromising the building’s security posture. Prospective bidders should consult Section L of the SF 1442 for full instructions and conditions governing proposal preparation and submission.
General Info
Agency
NAICS
Place of Performance
5323 E McKinley Ave, Fresno, CA, Fresno, CA, 93727, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
The full solicitation is posted on the PIEE solicitation module at: https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=W50S6T26BA019¬iceType=SolicitationNotice
Bids must be submitted through the PIEE solicitation module. Details are located at Section L - Instructions, Conditions, Notices to Offerors or Quoters on the SF 1442. Prospective contractors must gain solicitation submission access through https://piee.eb.mil/
The 144th Fighter Wing at Fresno Air National Guard Base (ANGB) intends to award a single firm-fixed-price contract for non-personal construction services, to include all plant, labor, transportation, materials, tools, equipment, permits, and supervision necessary to remove four existing Heating, Ventilation, and Air Conditioning (HVAC) units and their auxiliary air ducting and electrical and drain lines. After all existing HVAC units have been removed, the contractor shall install a new 40-ton HVAC system, necessary ducting, electrical, and drain lines to provide for the following training equipment environmental constraints - Operating Temperature: 59 to 78 F, (15 to 26 C), Operating Humidity: 35% to 80% RH (non-condensing), Storage Temperature: 32 to 120 F, (-29 to 38 C), Storage Humidity: 20% to 80% RH (non-condensing). Services shall also include the removal and replacement of existing dust covers with custom-made roof adapters to transition from current ductwork in room serviced by the new packaged units. In order to maintain the existing security integrity of the building and comply with Intelligence Community Directive (ICD) Number 705, no new penetrations in the building are permitted. The Contractor must use existing penetrations to the maximum extent practicable. All work must also conform to Unified Facilities Criteria (UFC) 3-410-01. Site visit details are located at Section L - Instructions, Conditions, Notices to Offerors or Quoters on the SF 1442. A bid guarantee is required in accordance with provision 52.228-1 on the SF 1442.