Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on September 6, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

N045--Install Control Sensors for Johnson Controls Metasys Network Automation Building Management System

Closed
36C26222Q1689Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334512
New
DIBBS
SWITCH, THERMOSTATIC
Solicitation # SPE7M8-27-T-0480
Solicitation SPE7M8-27-T-0480 is a request for quotations issued by the DLA Weapons Support Electrical Devices Division for the procurement of six thermostatic switches, identified by NSN 5930016019386 and Texas Instruments part number 11041-32-268. This is a restricted source item requiring engineering source approval by the government design control activity and is designated as a critical application item. The delivery is set for 235 days after the order is placed, with a need ship date of July 3, 2027, and a final required delivery date of October 31, 2027. Shipping is FOB Origin, with the destination for inspection and acceptance being the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to the DLA Master List of Technical and Quality Requirements, including specific protocols for packaging, configuration change management, and the removal of government identification from non-accepted supplies. Packaging must comply with MIL-STD-129 and RP001, with hazardous materials requiring adherence to FED-STD-313 and TQ requirement IP025. Additionally, the contract prohibits the intentional addition of mercury or mercury-containing compounds except where functionally required. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and compliance with the Buy American and Balance of Payments Program, as well as various FAR and DFARS clauses regarding cybersecurity, safeguarding covered defense information, and the prohibition of covered defense telecommunications equipment.
DLA WEAPONS SUPPORT ELECTRICAL DEVICES DIV

POSTED

about 21 hours ago

DEADLINE

in 11 days

General Info

NAICS

334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use

Place of Performance

Department of Veterans Affairs VA Long Beach Healthcare System 5901 East 7th Street Long Beach, CA 90822, AZ

Set-Aside

NONE

Documents

1

36C26222Q1689.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Office AddressGilbert, AZ, 85297, USA

Full Description

Show more
RFI # 36C26222Q1689 REQUEST FOR INFORMATION (RFI) SOURCES SOUGHT ISSUED FOR MARKET RESEARCH DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. REQUIREMENT DESCRIPTION Control Sensors for New Monitoring Points Hot Water Distribution Responses to this Sources Sought request shall be in writing. The purpose of this Sources Sought Announcement is for market research only to make appropriate acquisition decisions and to gain knowledge of small business capabilities, including Service Disabled Veteran Owned Small Business and Veteran Owned Small Business (SDVOSB/VOSB) interested sources capable of performing the work. The NAICS for this requirement is NACIS 238990 All Other Specialty Trade Contractors. SCOPE-Requirement Description General. Installation of control sensors with set-up of critical alarm set points, notification and trending reports, mapping new points to existing building management system, and programming/ commissioning all new points to monitor critical mechanical room areas through Johnson Controls Metasys® Software. Contractor will provide all required material to fully complete the job at the following: VA Long Beach Healthcare System 5901 East 7th Street Long Beach, CA 90822 Typical VA Hours will be Monday - Friday 8:30 AM to 4:30 PM local time, excluding Federal Holidays New Year s Day Martin Luther King Day President's Day Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day The Government will accept any wider range of coverage offered (i.e. 24/7, holidays included, etc.) The contract will be set up for an estimated completion of four months under a firm-fixed price, anticipating to award in September 2022. The criteria for selecting the contractor will be based on installation of the Brand Name or Equal to the following control sensor requirements which must be compatible with the existing Johnson Controls Metasys® Software building management system (Contractor shall coordinate with Johnson Controls for programming requirements): The Brand Name for controls sensors is Hach. All 12 sensors must have capability for outlet/inlet temperature between 5 - 40 °C (41 - 104 °F), with programmable setpoints for the following monitoring points: Monitoring Points Contractor shall connect building 165/166 (Mechanical Room E003) Hot Water Distribution System. To include the following monitoring points: Hot Water Supply High Temperature Alarm Status. Install Hot Water Discharge Sensor. Contractor shall connect building 164 (Penthouse Mechanical Room) Hot Water Distribution System. To include the following monitoring points: Hot Water Supply High Temperature Alarm Status. Contractor shall connect building 7 (Caged Room 12A) Hot Water Distribution System. To include the following monitoring points: Hot Water Supply High Temperature Alarm Status. Heat Exchanger Dump Valve Status. Contractor shall connect building 1 (Mechanical Room B-018) Hot Water Distribution System. To include the following monitoring points: Hot Water Supply High Temperature Dump Alarm Status. Heat Exchanger Dump Valve Status. Contractor shall connect Building 133 (Mechanical Room W61) Hot Water Distribution System. Contractor shall connect Building 128 (Mechanical Room C204) Hot Water Distribution System. To Include the following monitoring points: Hot Water Supply High Temperature Dump Alarm Status. Contractor shall connect the Bulk Liquid Oxygen Storage Tank, Telemetry Unit, for the monitoring of Cryogenic level and pressure measurements of storage tank. This requires running 120V AC power line to the Telemetry Unit and Metasys communication cables (Metasys Controller located in building 5C HVAC Shed). Oxygen Tank Level Telemetry already has a two-channel isolation card installed for the Metasys and also needs a 24volt connection. Contractor shall connect Building 160 (Water Heater Room 124) Hot Water Heaters. To include the following monitoring points: Install (Mirius RS-485) gateway to electric water heaters one and two; Water Heater Control Panel to communicate and monitor heater points. [Heater Model (1) DSE-40A-200, S/N 1830111275818. [Heater Model (2) DSE-40A-200, S/N 1830111275817] Install two industrial control communications gateway(s) (XLTR-1000 RS-485). Contractor shall connect Building 126 (Mechanical Room 625) Hot Soft Water Heater. To include the following monitoring points: Install (Mirius RS-485) gateway to hot soft water heater control panel to communicate and monitor different points. [Heater Model DSE-100A, S/N 0939R000030]. Install industrial control communications gateway (XLTR-1000 RS-485). Contractor shall connect Building 126 (Mechanical Room 31) Hot Water System. To include the following monitoring points: Horner X10 OCS (HE-X10R) Touchscreen PanelView, to be able to monitor 21 Hot Water Temperature Return Lines Status. Recirculation pump, to monitor the On/Off (current sensor), operation status. Reconnect/Extend On/Off (current sensor) from recirculation pump from wall junction box to panel view (approximately 5 feet away). Hot water over-temperature valve status. Contractor shall connect Building 125 Domestic Cold Water, inlet to water pumps. Contractor shall provide the Incoming City Water Quality Monitoring. Components as follow: Contractor shall install HACH CL 17sc Colorimetric Chlorine Analyzer P/N 8572900, QTY. (1) Contractor shall install HACH Reagent Kit for Free Chlorine P/N 2556900, QTY. (3) Must detect ranges: 0.03 - 5.00 mg/L Cl for CL17, 0.03 - 10.00 mg/L Cl for CL17sc Contractor shall install HACH CL 17 Installation kit P/N 8565700, QTY. (1) Contractor shall install HACH ¾ Flow Cell Assembly P/N 9180200, QTY. (2) Contractor shall install HACH 1 Flow Cell Assembly P/N 9180200, QTY. (1) Contractor shall install HACH pHD sc Digital Differential Sensor P/N DPD1P1, QTY. (1) Contractor shall install HACH Digital Inductive Conductivity Sensor P/N D3725E2T, QTY. (1) Accuracy: ± 0.01 % of reading, all ranges Body Material: Polypropylene Cable Length: 22 ft Flow: Rate 3 m (10 ft.) per second, maximum Material: Polypropylene Mounting: Convertible Operating Temperature Range: -10 - 200 °C Range: 200 µS/cm - 2000 mS/cm Sensor Cable: Polypropylene and PVDF Sensors: 5 conductor (plus two isolated shields) cable with XLPE (cross-linked polyethylene) jacket; rated to 150 °C (302ºF); 6 m (20 ft.) long Sensor Type: Digital Temperature Sensor: Temperature Compensator Pt 1000 RTD Warranty: 12 months Wetted Materials: Polypropylene, PVDF, PEEK® or PFA® Contractor shall install HACH Digital SC4500 Controller P/N LXV525.99E11551, QTY. (3) Altitude: 2000 m (6562 ft) maximum Analog Output Functional Mode: Linear, PID Communication (optional): Analog: Five 0-20 mA or 4-20 mA analog outputs on each analog output module up to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input. Digital: Profibus DPV1 module Modbus TCP Profinet IO module Ethernet IP module Compatible Instruments: Compatible Sensors and Analyzers / Software Version (Release Year) Amtax sc / V2.30 (2018) or higher A-ISE sc / V1.02 or higher AN-ISE sc / V1.08 (2013) or higher N-ISE sc / V1.02 or higher Nitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higher Phosphax sc / V2.30 (2018) or higher Phosphax sc LR/MR/HR / V1.01 (2018) or higher TSS sc / V41.73 (2013) or higher Solitax sc / V2.20 (2013) or higher TU5300sc, TU5400sc / V1.34 (2017) or higher SS7 sc (in Bypass) / V1.06 (2006) or higher Ultraturb sc / V3.06 (2017) or higher 1720E / V2.10 (2006) or higher Sonatax sc / V1.15 (2016) or higher CL17sc / V2.7 (2019) or higher CL10sc / V1.14 (2013) or higher 9184sc, 9185sc, 9187sc* / V2.03 (2013) or higher Uvas plus sc / V3.01 (2017) or higher LDO 2 sc* / V1.22 (2013) or higher 3798sc* / V2.03 (2013) or higher 3700sc + Inductive Conductive Digital Gateway 6120800 / V3.00 (2017) or higher 3422sc, Analog 3400 + Contacting Cond. Digital Gateway 6120700 / V3.00 or higher pHD sc*, pHD-S sc / V3.10 (2016) or higher 1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higher RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher 8362sc* / V3.00 (2017) or higher *Hardware Version1 of instrument is not supported Compatible Network Technologies: GSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.) CDMA (e.g. Verizon) Compliance Certifications: CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C (Morocco) Conduit Openings: ½" NPT conduit Description: Microprocessor-controlled and menu-driven controller that operates the sensor Dimensions: ½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.) Display: 3.5-inch TFT colour display with capacitive touchpad Enclosure Rating: UL50E type 4X, IEC/EN 60529 IP 66, NEMA 250 type 4X Metal enclosure with a corrosion-resistant finish Installation Category: Category II Material Enclosures: Polycarbonate, aluminum (powder coated), stainless steel Measurements: Two device digital SC connectors Mounting: Wall, Pole, or Panel Mounting Network Connectivity: LAN: Two Ethernet connectors (10/100 Mbps) Cellular: External 4G Wi-Fi Operating Temperature Range: -20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load) -20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C) Outputs: 5x mA Output Pollution Degree: 4 Power Requirements (Voltage): 100-240 VAC ±10%, 50/60 Hz; 1 A Power Supply: With US plug Protection Class: I, connected to protective earth Relays: Two relays (SPDT); Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG) Maximum switching voltage: 100 - 240 VAC Maximum switching current: 5 A Resistive/1 A Pilot Duty Maximum switching power: 1200 VA Resistive/360 VA Pilot Duty Sensor Input #1: Digital Sensor Input #2: Digital Software available: Non-Claros + Embedded Prognosys Storage Conditions: -20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing USB Port: Used for data download and software upload. The controller records approximately 20,000 data points for each connected sensor. Warranty: 12 months Weight: 3.7 lb (controller only, w/o modules) Contractor shall connect and provide new points to the building 125 Incoming City Water for the following: Free Chlorine Conductivity Total Dissolved Solids (TDS) pH Temperature Contractor shall install Water Quality Monitoring, located inside the Pump House (B-125), mounted on a Unistrut Panel or Enclosure Panel. Analyzer and Flow Cell sample water will be discharge to floor drain. Interested and capable sources shall respond to this notice by completing the source questionnaire herein and emailing to contact@example.gov (reference RFI # 36C26222Q1689 in the email subject heading), no later than Thursday, 9/8/2022 at 4:00 p.m. Pacific- Los Angeles Time. SOURCE QUESTIONNAIRE Enter Company Name and Address. Enter DUNS Number. Enter Point of Contact Name, Phone, Email. Business size status and representation (Select All that Apply): Service-Disabled Veteran-Owned Small Business (registered in VetBiz.gov) Veteran-Owned Small Business (registered in VetBiz.gov) Woman-Owned Small Business Emerging Small Business HUBZone Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act Small Business Large Business Considered a small business under NAICS code identified for this RFI? Yes No Select/Complete All that Apply: FSS/GSA: Contract Number; Effective Dates: MM/DD/YYYY MM/DD/YYYY NASA SEWP: Contract Number; Effective Dates: MM/DD/YYYY MM/DD/YYYY Are all items of inquiry available on contract schedule? Yes No Provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor specifically for the required scope of work. Respondents are encouraged to provide targeted examples of the Contractor s experience providing the same or similar supplies/services (i.e. when attaching brochures, citing/making references to performance descriptions located within brochures that match the specific work requirement. Include attachments with drawings/illustrations as needed. Provide general pricing for products or services inquired. Include attachments as needed. Provide feedback or additional suggestions. If none, enter N/A. Small Business Respondents. SDVOSB or VOSB respondents are encouraged to provide proof of www.vetbiz.gov certification. Contractors are asked to acknowledge that they understand the limitations on sub-contracting pursuant to FAR 52.219-14, Limitations on Sub-Contracting, which will be included in the impending solicitation. Contractors are asked to respond that they are capable of providing the requested services keeping within the parameters of this clause. Small businesses are also advised that per 13 CFR § 125.6 the prime contractor's limitations on subcontracting are as follows: General. In order to be awarded a full or partial small business set-aside contract with a value greater than the simplified acquisition threshold, a small business concern must agree that: In the case of a contract for services (except construction), it will not pay more than 50% of the amount paid by the government to it to firms that are not similarly situated. Any work that a similarly situated subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Complete the fields hereunder if utilizing a subcontractor to perform the requirement. Enter Sub Contractor Company Name and Address. Enter DUNS Number. Enter Point of Contact Name, Phone, Email. Business size status and representation (Select All that Apply): Service-Disabled Veteran-Owned Small Business (registered in VetBiz.gov) Veteran-Owned Small Business (registered in VetBiz.gov) Woman-Owned Small Business Emerging Small Business HUBZone Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act Small Business Large Business Please note that if VA s pending market research establishes that two or more VOSB or SDVOSB, who are certified in VA s Vendor Information Pages (VIP) site https://www.vip.vetbiz.gov/, can perform the services, VA will set aside the underlying solicitation per 38 U.S.C. §8127. All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) database found at https://www.sam.gov. Registration must include Representations and Certifications. --End of Sources Sought Announcement--

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 562211
New
Federal
F999--Hazardous Material & Waste Disposal
Solicitation # 36C26227Q0071
The Department of Veterans Affairs, through Network Contracting Office 22, has issued a sources sought announcement under solicitation number 36C26227Q0071 to identify qualified contractors for hazardous material and waste management services. This is a market research effort and not a formal solicitation for award. The scope of work involves providing all labor, materials, equipment, and transportation for hazardous waste disposal, collection, and emergency response services. Performance will take place at the Greater Los Angeles VA Healthcare System West LA Main Campus and various Community Based Outpatient Clinics, including locations in San Gabriel Valley, Santa Barbara, Santa Maria, San Luis Obispo, Bakersfield, and the Captain Rosemary Bryant Mariner clinic. The acquisition is classified under NAICS code 562211 for Hazardous Waste Treatment and Disposal, with a size standard of 47.0 million dollars. In accordance with Public Law 109-461, the government is considering a total set-aside for Service-Disabled Veteran Owned Small Businesses, though it may opt for alternate set-asides or full and open competition based on the responses received. Interested firms must be registered in the System for Award Management and, if applicable, the SBA VetCert system. To be considered, respondents must submit a capability statement detailing their qualifications and past performance from the last five years, along with a completed price schedule for market research purposes. All submissions must be emailed to the contract specialist by November 6, 2026.
Hazardous Waste Treatment and Disposal

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 811111
New
Federal
Yuma Mobile Vet Center (MVC) Repair
Solicitation # 36C26227Q0055
The Department of Veterans Affairs, through the Southern Arizona Health Care System, is soliciting quotes for a firm-fixed-price service contract to perform non-mechanical body repairs on Mobile Vet Center 0828. The scope of work involves repairing cosmetic and potential structural damage to the driver's rear side, including the removal and replacement of damaged body panels, decals, and the body wrap. The selected contractor will be responsible for repainting repaired surfaces to match the existing finish and providing a craftsmanship warranty on all work. Performance will take place in Tucson, Arizona, with a base period of performance from December 1, 2026, to November 30, 2027. This opportunity is a total Small Business Set Aside, and the government will evaluate offerors based on their service-disabled Veteran-owned or Veteran-owned small business certification status and their intent to use such entities as subcontractors. Proposals must be submitted by November 9, 2026, at 11:00 am. A site visit is scheduled for November 3, 2026, in Tucson. To be eligible for award, offerors must provide a signed certification regarding limitations on subcontracting and represent compliance with FASCSA and telecommunications prohibitions. Payments will be processed via Electronic Funds Transfer through the System for Award Management.
General Automotive Repair

POSTED

1 day ago

DEADLINE

in 11 days
View Details
NAICS: 335910
New
Federal
6135--UPS Battery Replacement
Solicitation # 36C26227Q0064
Solicitation 36C26227Q0064 is a firm-fixed-price request for quotes issued by the Department of Veterans Affairs, NCO 22, for the one-time replacement of 60 batteries for the Main Server Uninterrupted Power Supply (UPS) at the San Diego VA Medical Center. This procurement is a total small business set-aside under NAICS code 335910, with a small business size standard of 1,250 employees. The scope of work requires a certified technician to remove and replace 60 C&D UPS12-545PLP batteries across two cabinets in Building 1, Room BB100-1. The contractor is responsible for all freight, installation, testing, removal, and recycling costs, and must ensure the work is completed during one coordinated event within 365 days after receipt of order. The award will be based on price only. Offerors must submit a completed and signed SF 1449 via email to the contracting officer by 15:00 Pacific Local Time on November 10, 2026. Required submission elements include the vendor's SAM UEI number, acknowledgement of amendments, specific manufacturer and model numbers, and a certificate of compliance regarding limitations on subcontracting. Performance requires strict adherence to safety protocols, including Lock out/Tag out procedures on the primary feed and tightening terminals to manufacturer torque specifications. The contractor must maintain all necessary licenses and insurance, and comply with Buy American and other federal regulatory clauses.
Battery Manufacturing

POSTED

1 day ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS