NCC UPS-COMM Closet UPS

Closed
W50S7526QZ030Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 335999
New
DIBBS
TAPE, INSULATION, ELECTR
Solicitation # SPE4A6-26-T-27CU
Solicitation SPE4A6-26-T-27CU is a Request for Quotations issued by the DLA Aviation ASC Commodities Division for the procurement of electrical insulation tape, identified by NSN 5970-00-480-1329. The requirement consists of multiple line items with quantities ranging from 1 to 20 rolls, with required delivery dates scheduled between August 28 and September 8, 2026. Delivery is required within five days of the award, with FOB, inspection, and acceptance all set at the destination. Shipments are directed to various locations, including the USS Shoup DDG 86, the DLA LMP Zone 1 depot in Texas, the Lockheed Martin Distribution Center in Georgia, ASD Oceana in Virginia, and the Base Naval de Rota in Spain. The contractor must adhere to strict quality and packaging standards, including sealing each tape in a waterproof polyfilm bag and packing 10 to 12 rolls per intermediate container. All marking must comply with MIL-STD-129, specifically using Special Marking Code 32 for Type I shelf-life items, which have a non-extendable shelf life of 18 months. The use of mercury or mercury compounds is strictly prohibited in all preservation, packaging, and marking. Technical and quality requirements are further governed by the DLA Master List and RP001 packaging requirements. Evaluation for award will consider price, with a preference for certified HUBZone Small Business Concerns. Offers utilizing additive manufacturing processes are ineligible for award. The procurement is subject to the Buy American Act and the Berry Amendment, requiring disclosure of any non-domestic materials. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and compliance with DFARS cybersecurity standards for safeguarding covered defense information.
ASC COMMODITIES DIVISION

POSTED

about 16 hours ago

DEADLINE

in 4 days

AI Contract Overview

Show more

The California Air National Guard’s 146th Airlift Wing is seeking quotes for a combined requirement covering a 50 kW / 50 kVA uninterruptible power supply (UPS) for the Network Control Center and five each of 3000VA/2700W and 1920VA/1920W lithium-ion UPS units for communications closets. The NCC UPS must support 208V AC, 3-phase input and output with compatibility for 200V and 220V, feature an external lithium-ion battery system operating between 384–480V DC, and include a freestanding tower form factor with embedded network management, an LCD touchscreen interface, and N+1 redundancy. The system must also include a maintenance bypass cabinet and two lithium-ion battery cabinets with UL 9540A compliance, each equipped with a battery management system and data logging capability. The requirement includes comprehensive service support: one year of extended on-site warranty, five additional planned maintenance visits during normal business hours, a one-time startup and assembly service for the battery cabinet, and tiered labor rates for normal, after-hours, and holiday service. The COMM closet UPS units must be TAA compliant, 2U rack/tower units with lithium-ion batteries and 120V output. The contract is planned as a firm-fixed price, 100% small business set-aside under NAICS code 335999, with a target completion date of March 31, 2027. Interested vendors must register in SAM.gov and submit interest via email to the designated points of contact by 4:30 PM PDT on August 6, 2026, to be considered for the upcoming solicitation, which will be posted on SAM.gov and not distributed via hard copy or CD.

General Info

146th Airlift Wing seeks 50kW UPS and five lithium-ion UPS units with TAA compliance, UL 9540A, N+1 redundancy, and five-year service support.

Agency

Department Of Defense → W7MX Uspfo Activity Caang 146View Agency

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component ManufacturingView NAICS

Place of Performance

Port Hueneme, CA, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7MX Uspfo Activity Caang 146
Contacts1 person available
OfficePORT HUENEME, CA, 93041-4011, USA
Organization / Agency
Department Of Defense → W7MX Uspfo Activity Caang 146
View Agency Profile
Office AddressPORT HUENEME, CA, 93041-4011, USA
Contacts
Ricardo Macias

Full Description

Show more

This announcement is for information and planning purposes. It is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. 


The California Air National Guard, 146th Airlift Wing (146th AW) Channel Islands ANG Station, Port Hueneme has requirements entitled: NCC UPS and COMM Closet UPS


The 146th AW intends to solicit quotes from at least three (3) interested sources in accordance with RFO FAR 12.201-1 Simplified procedures.  This is expected to be 100% set aside for a Small Business competition after approvals are completed and is intended to result in award of one (1) firm-fixed price contract with an expected contract delivery/contract completion date of 31 March 2027.


The general salient characteristics of the requirement include but are not limited to:


NCC UPS:


-Uninterruptible power supply, rated at 50 kW / 50 kVA, operates with a 208V AC,


3-phase input and output, configurable also for 200V and 220V. It's engineered for


external battery systems, accommodating Lithium-Ion batteries with a nominal


battery voltage range of 384-480V DC. Freestanding tower, approximately 58.5


inches tall, 20.5 inches wide, and 33.3 inches deep, weighing 551 to 639 lbs. without


batteries. Includes an LCD touchscreen for user interaction, an embedded network


management card for remote monitoring and software compatibility. Offers overload


capacity (125% for 10 minutes, 150% for 60 seconds), with some supporting N+1


redundancy for enhanced availability.


Power Rating: 50 kW / 50 kVA.


Input Voltage: 208V AC, 3-phase. Also supports 200V and 220V.


Output Voltage: 208V AC, 3-phase. Also configurable for 200V and 220V.


Battery System: Designed for an external battery system, supporting Lithium-Ion


battery types. The nominal battery voltage range is 384-480V DC.


Efficiency: Can achieve up to 99% efficiency in high-efficiency operating modes.


Form Factor: A single, freestanding tower unit.


Physical Dimensions: Approximately 58.5 inches in height, 20.5 inches in width, and


33.3 inches in depth.


Weight: 551 to 639 lbs, without batteries.


User Interface: Features a touch screen LCD for monitoring and management.


Overload Capacity: 125% of its rated load for 10 minutes and 150% for 60 seconds.


Redundancy: N+1 redundancy with an additional power module for increased


availability.


Connectivity: Includes an embedded network management card for remote


monitoring and is compatible with various infrastructure management software.


-Maintenance bypass cabinet for complete isolation of the UPS during service


operations Component Type Cabinet Physical Color White Height 58.5 in (148.5


cm) Width 12.5 in (31.8 cm) Depth 33.5 in (85 cm) Product Weight 264.6 lb(US)


(120 kg) Single Unit 50-75kW 208V, 100-150kW 480V


-Lithium-ion Battery Cabinet UL with 16 x 2.0 4 kWh battery modules Battery Management System (BMS), switchgear, power supply, and communication interface. Battery Type Li-Ion (Lithium Ion) Provided Equipment Installation guide Batteries & Runtime Battery Placement Battery Cabinet Battery manufacturer Samsung Device mounting Enclosed battery cabinet Physical Color White Height 77.6 in (197 cm) Width 25.6 in (65 cm) Depth 23.1 in (58.7 cm) Product Weight 1036.2 lb(US) (470 kg) Surface Finish Powder coated Output Battery Capacity 67 Ah Conformance Standards UL 9540A


-Lithium-ion Battery Cabinet downloadable stored data log system from the battery used for monitoring.


-1 Yr EAA Prevent Srvc Upgrade to FW or Existing Srvc Plan for (1) 3P UPS 41 to 150kVA


-1 Year On-Site Warranty Ext for (1) 30 to 50kW UPS


-Additional Contract PM Visit 5X8 for (1) 30 to 50kW UPS


-1 Year 4HR 7X24 Response Upgrade to Factor Warranty or Existing Service Contract for 41 to 150 kVA


-1 Startup Service for 1 Cabinet Li-Ion Battery solution


-Assembly Service for 1 Cabinet Li-Ion Battery solution 1


-Per Hour Service Labor Rate during Normal Business Hours


-Per Hour Service Labor Rate for After Hours Service during Normal Business Days


-Per Hour Service Labor Rate during Weekends and Holidays



COMM Closet UPS:


- UPS Lithium-Ion TAA Compliant 3000VA/2700W 120v 2U Rack/Tower (QTY 5)


- UPS Lithium-Ion TAA Compliant 1920VA/1920W 120v 2U Rack/Tower (QTY 5)



The North American Industry Classification System (NAICS) code for this project is 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing with a small business size standard of 600 employees.


This Sources Sought/Pre-solicitation Notice is not a Request for Quote (RFQ), Request for Proposal (RFP), or an Invitation for Bid (IFB).


This Notice is published for this proposed action in accordance with RFO FAR 5.101(a).  The 146 Wing will provide more information in the official solicitation.  Quotes will be due no less than 10 days from the date the solicitation is issued.  The definitive due date and time will be stated in the solicitation and any associated amendments that may be issued.


No CDs or hard copies of the solicitation will be available.  Interested vendors are responsible for checking https://SAM.gov for any update(s) to this Notice.  The Government is not responsible for any loss of Internet connectivity or for any vendor’s inability to access any documents posted on the above-mentioned website.


To conduct business with the Department of War, a Contractor must provide registration information to the System for Award Management (SAM).  All offerors must be actively registered at SAM prior to receiving an award.  Registration instructions may be obtained, and online registration may be accomplished at https://SAM.gov.


This announcement is for information and planning purposes.  If your firm is interested in this requirement and would like to receive the RFQ when distributed, email your interest and firm’s contact information with SAM UEI# to ricardo.macias.3@us.af.mil and william.tucker.32@us.af.mil on or before 4:30 PM PDT on 06 August 2026.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS