Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Mid-Atlantic
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Mid-Atlantic
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
PRIORITY CNIC 1 MAXIMO 5 1.Rust at the bases of rigid frame columns. These columns are constructed of two structural steel channels each. 2.Paint peeling and grout spalling at base of walls/top of foundation wall. 3.Rusting of personnel doors and frames. 4.Steel plate adjacent to hanger door rails. Original coating/paint is gone and plate is rusting. 5.Hanger door rails wearing and possibly settling. 6.Personnel door in east elevation has a large hole rusted through the frame. 7.Rubber isolators (or bushings) in anchor bolt assemblies are deteriorating and becoming hard and crumbling. 8.Winch baseplate and lower chassis has peeling paint and is rusting. 9.Compressed air system piping has peeling paint and is rusting. 10.Exterior slab has settled around the office area of the building and has broken the sealant. 11.Large valve for oil-water separator is broken. This is underground in a vault under a manhole cover. 12.Exterior store room/mechanical room door is rusted through (adjacent to main entry door). 13.Door sweeps on exterior doors are worn out and not working. 14.All exterior doors and frames need either complete renovation or replacement. 15.Exterior piping for sprinkler system (FDC) has peeling paint and oxidation. 16.Exterior compressed air tanks are oxidizing and have peeling paint. 17.The base of the hangar walls at the southwest corner shows evidence of more water getting into the building than other areas, and is rusting more severely. 18.Cracks in the concrete walls of the exhaust stack are very evident as are the concrete joints. More severe cracks are in the concrete walls at foundation level adjacent to the retaining walls on two sides.