This Solicitation opportunity from Department Of Defense was posted on February 13, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
OPS EAID GENERATOR REPLACEMENT
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This contract involves the replacement of two 200kW generators that have reached the end of their service life and need to be updated with more efficient, EPA-compliant models. The specified units to be provided are two Cummins C200D2RE: T4F Mobile generators, each delivering a standby output of 200 kW and a prime output of 180 kW at 60Hz, equipped with Cummins QSB 6.7L engines and including a paralleling harness. These generators are accessible through the GSA schedule. The solicitation, titled "OPS EAID GENERATOR REPLACEMENT," is issued by the Department of Defense and is designated as a total small business set-aside under NAICS code 335312. The opportunity is based in Nebraska, with performance expected in St. Columbans, NE. The solicitation was posted on January 30, 2026, with a response deadline of February 19, 2026. Primary and secondary points of contact for inquiries are Jason Arizmendi and Daniel Kuchar, respectively, both reachable via provided phone numbers and email addresses.
General Info
Place of Performance
St Columbans, NE, 68113, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Amendment 0002 13FEB2026 - Amended Performance Work Statement document into a Statement of Need. Removed the need for paralleling harness. Removed service component of requirement. See Statement of Need for full requirement scope. Added Attachment 04 - Question and Answer - 2.13.26.
Amendment 0001 09FEB2026 - 52.212-1 Amended in solicitation to reflect new questions due date of 12FEB2026 by 10:00 AM.
This requirement is for two (2) 200kW generators. The generators to be replaced are at the end of their service life and need to be replaced by more efficient and EPA compliant generators.
The following items shall be provided: 2 each, Cummins C200D2RE: T4F Mobile 200 kW standby output/ 180 kW prime output; 60Hz: Cummins QSB 6.7L generators (available via GSA) and paralleling harness.
More opportunities from Department Of Defense → FA4600 55 Cons Pkp
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS