Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

OXIMETER, PULSE

Open
SPE2DS-27-T-1840Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Solicitation SPE2DS-27-T-1840, issued by the Defense Logistics Agency (DLA) Troop Support Medical Supply Chain, is for the procurement of 40 Masimo MightySat Rx Pulse Oximeters. These devices are specifically designed for patient movement environments, such as transport or conditions involving shivering and cold, and are capable of measuring pulse rate, SpO2/oxygen saturation, and perfusion index. Technical specifications require the units to be powered by two AAA alkaline batteries, providing approximately 1800 spot checks, with an operating temperature range of 41 to 104 degrees Fahrenheit and a storage range of -40 to 158 degrees Fahrenheit. Each unit weighs 0.16 pounds and measures 2.9 x 1.6 x 1.2 inches. The contract mandates that items be delivered FOB Destination to Camp Pendleton, California, within 20 days after award. Packaging must follow commercial standards and ASTM D3951, with a requirement for sealed unit containers to prevent damage. Marking must adhere to Medical Marking Standard No. 1, which supersedes MIL-STD-129. The procurement is subject to various federal regulations, including the Buy American Act, DFARS cybersecurity reporting requirements, and the use of the Wide Area WorkFlow (WAWF) system for invoicing and payment. Inspection and acceptance will occur at the destination.

General Info

DLA procurement of 40 Masimo MightySat Rx Pulse Oximeters for Camp Pendleton.

NAICS

339112 - Surgical and Medical Instrument Manufacturing

Place of Performance

BOX 555243, CAMP PENDLETON, CA, 92055-5243, USA

Set-Aside

NONE

Documents

1
PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
ContactsNo contacts available
OfficeUSA
Office AddressUSA
ContactsNo contact information available

Full Description

Show more
OXIMETER,PULSE
OXIMETER, PULSE
MASIMO MIGHTYSAT RX PULSE OXIMETER THAT
MEASURES PULSE RATE, SPO2/OXYGEN SATURATION
AND PI/PERFUSION INDEX, SPECIFICALLY DESIGNED
FOR USE IN PATIENT MOVEMENT ENVIRONMENTS WHERE
PATIENTS ARE EFFECTED BY BODILY MOVENTS CAUSED
BY SHIVERING/COLD AND TRANSPORT; REQUIRES 2 AAA
STANDARD ALKALINE BATTERIES; OPERATING TEMPERATURE<(>,<)>
41 5O 104 DEGREES F; STORAGE TEMPERATURE, -40 TO 158 DEGREES F;
WEIGHT, 0.16 POUNDS; DIMENSIONS, 2.9 X 1.6 X 1.2 INCHES; BATTERY LIFE
<(>,<)>
APPROXIMATELY 1800 SPOT CHECKS
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS
SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED
IN A SUITABLE SEALED UNIT CONTAINER CAPABLE
OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR
BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL
EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
TROOP SUPPORT VIA EMAIL TO Sign up to see this detail. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
UNIT OF ISSUE: EACH (EA)
.
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
SPE2DS-27-T-1840
SECTION B
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-655-9412 Quantity: 40 EA Purchase Request: 7019117311QTY: 40 Delivery: 20 days ADO

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS