Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on March 25, 2010. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Pantex Renewable Energy Project

Closed
PREPFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Department Of Commerce Nist

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 236210
New
Federal
Sources Sought - POST TEST LITHIUM BATTERY STORAGE
Solicitation # N00167-27-RFPREQ-CD-102-0002
The Naval Sea Systems Command Naval Surface Warfare Center Carderock Division is conducting a sources sought effort for the construction of a Post-Test Lithium Battery Storage Facility in West Bethesda, Maryland. This project, classified under NAICS code 236210 for Industrial Building Construction, involves the creation of a storage area featuring a non-flammable single-pitch sloped roof, a perimeter fence with a gate, 3-hour rated firewalls, and concrete walls for large battery storage. Additional requirements include low-voltage outlets, pole-mounted LED flood lighting, and a dedicated forklift access road. The effort must be completed within 210 days of the award and adhere to Unified Facilities Guide Specifications and other stringent technical criteria. This notice is not a request for proposal, and no award will be made directly from this notice. Interested small and large businesses must submit a capability statement and a Rough Order of Magnitude by 1700 EST on 18 November 2026 to Heather Valiga. The government will use these responses to determine the future acquisition strategy. Because the project is located on a secure military installation, all personnel must obtain proper clearances and credentials. Key deliverables include an Activity Hazard Analysis and a detailed schedule due within five days of the pre-construction meeting, as well as a personnel list provided seven days before the start date.
Nswc Carderock

POSTED

1 day ago

DEADLINE

in 29 days
NAICS: 236210
New
SLED
Arrowhead Regional Medical Center Lot 1 Parking Structure
Solicitation # 2026010330
The County of San Bernardino is soliciting the construction of the Arrowhead Regional Medical Center Lot 1 Parking Structure located at 400 North Pepper Avenue in Colton, California. The project consists of a post-tensioned, cast-in-place structure spanning up to 500,000 square feet across six levels, providing up to 1,600 parking spaces. Key design elements include a finished exterior with an architectural mesh facade on the first floor, two banks of two elevators, and the installation of photovoltaic panels on the top level. The facility will be restricted to employees via badge access and will feature security enhancements such as LED lighting, emergency call boxes, security cameras, and locked gates. The project must comply with the California Building Code, the Americans with Disabilities Act, the 2022 California Building Energy Efficiency Standards (Title 24), and the California Green Building Standards Code (CALGreen) for electric vehicle charging stations. Environmental mitigation includes a landscape plan to offset the removal of approximately 51 trees. To maintain parking capacity during construction, a temporary surface parking lot will be operated at 1351 West Valley Boulevard with shuttle services provided to the campus. The project has undergone CEQA review, resulting in a Mitigated Negative Declaration confirming that the project will not have significant environmental impacts provided mitigation measures are implemented.
San Bernardino County

POSTED

1 day ago

DEADLINE

N/A

General Info

Agency

N/A

NAICS

236210 - Industrial Building Construction

Place of Performance

PO Box 30020, AMARILLO, TX, 79120, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Vanessa L EverhartSmall Business Program Manager

Full Description

Show more
March 24, 2010 SUBJECT: SOURCES SOUGHT NOTICE PROJECT: Pantex Renewable Energy Project at Pantex Plant, Amarillo, Texas Babcock &Wilcox Technical Services Pantex, LLC, is seeking interested parties for the competitive procurement of a renewable energy facility, to be located on US Department of Energy property at the Pantex Plant in Amarillo, Texas. Background The B&W Pantex Plant is located on FM 2373 approximately 17 miles northeast of Amarillo. It is a Department of Energy (DOE) National Nuclear Security Administration (NNSA) nuclear weapons plant managed and operated by B&W Pantex. General Scope Description Electricity is a required utility as the Pantex Plant relies on electrical power to perform the functions of the Plant. The objective of the Pantex Renewable Energy Project (PREP) is to have a private entity design and build the wind farm on Government property, and subsequently execute a lease-to-own agreement with B&W Pantex. The PREP will provide a potential research opportunity for the National Wind Research Center (NWRC) to perform research and educational opportunities to further the use of renewable energy. The research entity or the NWRC shall have exclusive use of the wind farm to further energy technology, performance, reliability and effectiveness as part of the research effort. This project shall provide turnkey Contractor services for B&W Pantex. These services shall be for the design, equipment & material procurements, construction, start-up testing, plant personnel training, and completion of project closeout documentation (such as submittal of as-built drawing "mark-ups") for the Pantex Renewable Energy Project. More specifically, the project is comprised of: A. Wind Farm Requirements 1. Design-Build-Operate a 15 MW name plate (NP) generating capacity Wind Farm on Government property to include; a. Design/Purchase/Installation of wind turbines generators (WTGs). WTG size shall be between 1.5 - 3.0 MW generating capacity. WTGs shall be new and use current technology. b. Design/Construction/Installation of electrical distribution lines and transformers for connection of the WTGs. c. Design/Construction/Installation of electrical distribution lines connecting wind farm to Pantex distribution substation(s). 2. Wind Farm to be developed under a lease-to-own agreement with the Government. Government shall own the wind farm upon completion of installation and system becoming operational. 3. Government will make annual lease-to-own payments to the developer for no more than 25 years or until the mortgage is paid off to the developer after the wind farm is successfully operational. The Government shall also have the option to pay down the lease-own contract in lump sum amounts at any time. 4. Wind Farm Developer and Subcontractors shall comply with Pantex Security and site access requirements and the Wind Farm will be located in Pantex's lowest Security Area. 5. Wind Farm to supply power for Pantex Plant use. DOE/NNSA has an approved Qualifying Facility (QF) application. All electrical power generated per the QF (15MW NP) shall be property of the Government under the lease to own agreement. 6. Wind Farm to be Constructed/Installed on Government owned property. 7. Wind Farm WTGs to be available for research capabilities; a. Turbine operations to be interrupted as needed for equipment change out and instrumentation purposes. b. Turbine operations to be interrupted as needed for testing, instrumentation, maintenance, or training purposes. 8. Final location of WTGs (including height), size and design of wind farm to be approved by Pantex and Federal Aviation Administration (FAA). The FAA application has already been submitted for approval by the NNSA Pantex Site Office. 9. Wind Farm construction shall include installation of roads, supervisory control and data acquisition (SCADA) system, signage, fences, and other needed infrastructure for access and maintenance. 10. Pantex is located in a Class 4 Wind Power area. Meteorological data is available for the proposed site. 11. The Developer shall be responsible for warranty and maintenance for the determined warranty period and maintenance for the useful life of the WTG's. 12. A potential research element might exist with the 15MW of WTG's and any potential expansion. 13. Any future expansion of the Wind Farm under the project shall be on Government owned or Government controlled property up to 40 MW Average Generating Capacity (AGC). 14. Any future expansion on Government owned property will require the developer to pay land use royalties to the Government. 15. Power generated from future expansion above the 15 MWs NP shall be the property of the developer. The successful contractor will be required to submit a cutover strategy plan that identifies how electrical power will be provided to facilities during construction activities and how electrical power will be cut over from the existing system to the new. The new wind farm shall be installed such that both systems (new & existing) can remain operational independently &/or connected together. The maximum duration for facility outage to perform the actual cutover is limited and will require coordination with Pantex. We are seeking firms that would be interested in performing as the prime contractor. If you are interested, please respond via email to Gary D. Moore, Contract Specialist, E-mail: gmoore@pantex.com Estimated cost range $25 million to $50 million Interested Parties should be aware that federal stimulus funding under ARRA may become available for this project through the Department of Energy. Up to $28 million may be provided to fund power production by wind energy for the Pantex Plant. This could include purchase of the WTG's and towers comprising the Wind Farm, the electrical distribution lines inter-connecting the WTG's, and the electrical distribution lines connecting the Wind Farm to the existing Pantex Plant substation. In the event such ARRA funding becomes available, the Request For Proposal (RFP) will be amended to reflect appropriate changes to the scope of the project as described herein including Wind Farm ownership, lease-to-own agreements and other affected provisions.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS