Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Justice was posted on February 8, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Paving Building Fire Suppression System

Closed
15B40319QU8T30010Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334290
New
DIBBS
INTERFACE UNIT, COMMUNI
Solicitation # SPE4A7-27-T-2289
Solicitation SPE4A7-27-T-2289 is a request for quotations issued by the DLA Weapons Support ASC Supplier Oper AE and AF Div for the procurement of three interface units for communication equipment, identified by NSN 5895-01-739-0196. The requirement specifies parts from Watlow Electric Manufacturing Co (P/N 2292-6980 and PM6C1CJ-ARAAVWP). Delivery is required within 146 days after order, with a need ship date of April 1, 2027, and an original required delivery date of August 13, 2027. The items are to be delivered FOB Origin to the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to quality and packaging standards, including MIL-STD-2073-1E for packaging, MIL-STD-129 for marking, and RP001 for palletization. Inspection and acceptance will occur at the destination. Quality assurance follows MIL-STD-1916 or ASQ H1331, with a zero-nonconformance requirement for sample lots under MIL-STD-105/ASQ Z1.4. Administrative requirements include the use of Wide Area WorkFlow (WAWF) for invoicing and payment. The solicitation incorporates several federal regulations, including the Buy American and Balance of Payments Program, DFARS cybersecurity reporting requirements, and prohibitions on covered telecommunications equipment. Award may consider the HUBZone price evaluation preference.
DLA WEAPONS SUPPORT ASC SUPPLIER OPER AE AND AF DIV

POSTED

about 5 hours ago

DEADLINE

in 8 days

General Info

NAICS

334290 - Other Communications Equipment Manufacturing

Place of Performance

FCI ENGLEWOOD 9595 W QUINCY AVE, LITTLETON, CO, 80123, USA

Set-Aside

SBA

Documents

7

BP-A 0660 NCIC Check Authorization Form

PDF, Low priority2 pages · other
Low

15B40319QU8T30010.pdf

PDF

4B8T_Paving_Buiding_Revised_01_18_2019-FIRE.pdf

PDF

ENG_4B8T_Pvg_Bldg_Fire_Supression_Statement_of_Work.pdf

PDF

Notice_to_Offerors_fire_sprinkler.pdf

PDF

Paving_Building_Rigid_Frame_Plan.pdf

PDF

Paving_Building_Roof_Framing_Plan.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Jan 25, 2019 to Jan 31, 2019. The notice description changed.

Response Deadline

Deadline has passed

Notice updated

Notice details unchanged. Attachments may have changed.

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Justice → Fci Englewood
Contacts1 person available
OfficeLITTLETON, CO, 80123, USA
Office AddressLITTLETON, CO, 80123, USA
Contacts
Rachel A. BrownContracting

Full Description

Show more
The occupancy group is Ordinary Hazard, Group 2 (attached drawing reflects this change). The fire sprinkler design will need to accommodate one high volume, low speed ceiling fan and address how they will be tied into the fire suppression system in accordance with NFPA 72 High Volume Low Speed (HVLS) Fans. 20.6.7.1 The installation of HVLS fans in buildings equipped with sprinklers, including ESFR sprinklers, shall comply with the following: 1. The maximum fan diameter shall be 24 ft (7.3 m). 2. The HVLS fan shall be centered approximately between four adjacent sprinklers. 3. The vertical clearance from the HVLS fan to sprinkler deflector shall be a minimum of 36 in. (900 mm). 4. All HVLS fans shall be interlocked to shut down immediately upon a waterflow alarm. 5. Where the building is protected with a fire alarm system, this interlock shall be in accordance with the requirements of NFPA 72. Three gas-fired infrared tube heaters will need to be incorporated with the design of the sprinkler system and in accordance with NFPA 54. Manufacturer, Dayton; Model 7D849 150,000 BTUH Quotes are due by January 31, 2019 at 9am Mountain Time.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS