This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on March 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

PORTABLE REVERSE OSMOSIS FOR FARGO

Closed
Federal
Submission Closed
Solicitation #
36C26326Q0379

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract solicits a firm-fixed-price procurement for a portable reverse osmosis (RO) water purification system to be used in the Dialysis unit at the Fargo VA Medical Center. This system, specified as either the Evoqua W3T591409 Kit, RO Eon Rover ALX SCB or an equal product, incorporates a fully integrated multi-stage filtration process including carbon filtration, reverse osmosis, and ultrafiltration, meeting stringent ANSI/AAMI standards for ultrapure dialysate production. The system is designed with features such as endotoxin removal, easy-to-use controls, continuous hot water disinfection without chemicals, multiple leak detection options, and a color touch screen LCD control panel. It also includes a corrosion-resistant cart with large lockable casters, booster pump for low inlet pressure, and complies with all relevant UL, IEC, and FDA medical device certifications. The contractor's scope includes delivering, installing, and validating the new system at the Fargo VA Medical Center, ensuring all equipment and accessories are provided as required. Installation and assembly must be completed by a vendor-certified service representative who will also confirm all components are present and functional. Post-delivery, joint inspections with the Contracting Officer's Representative (COR) will verify completeness and functionality, with any discrepancies rectified at no additional cost to the government. The system’s design prioritizes a small footprint suitable for patient areas and includes detailed operational and safety features to ensure compliance with medical and safety standards. The procurement is a total small business set-aside and subject to compliance with the Buy American Act, emphasizing domestic product certification and meeting federal procurement requirements. The point of contact for this opportunity is located at the Network Contract Office 23, Department of Veterans Affairs in Saint Paul, MN, and the performance location is Fargo, North Dakota.

General Info

Firm-fixed-price purchase of portable RO water system for Fargo VA dialysis, certified, installed, inspected.

NAICS

339112 - Surgical and Medical Instrument Manufacturing

Place of Performance

Fargo, ND, 58102, USA

Set-Aside

SBA

Documents

3
DOCX, High priority: read this firstspecifications
High
PDF, High priority: read this firstrfq
High
PDF, Low prioritycertificate
Low

Read all 3 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • Deckover Equipment Trailer Manufacturing and SupplyOpen now, due in 11 days
  • Health Shared Services Provincial Health Corporation - Notice of Intent - Notice of Intent to Award Contracts for Heart Valve and Ring ProductsOpen now, due in 26 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts1 person available
OfficeSaint Paul, MN, 55101, USA

Full Description

Show more

CANCEL RFQ 36C26326Q0379. 




FUNCTIONAL/PERFORMANCE/SPECIFCATION


Description & Salient Characteristics: The Fargo VA Medical Center requires the purchase of a portable reverse osmosis (RO) water purification system in the Dialysis unit. The Fargo VA currently has a preventative maintenance contract with Evoqua for the units in Dialysis and SPS.


This request is a firm-fixed price.



STATEMENT OF WORK (SOW)


SCOPE:


-The contractor shall deliver and install the system with all specified salient


characteristics. --Only new equipment will be accepted.


-The contractor shall provide shipping, transport, installation, and all equipment


necessary to meet the requirements and capabilities listed within the scope.


-The contractor shall deliver the system to the Fargo VA Medical center.


-The assembly and validation of the system must be performed by a vendor service


trained representative.


-The contractor is responsible for identifying any missing parts or components not


included in the order for the RO Systems to be successfully installed and validated


to their full potential.


-The contractor shall include accessories and consumables that have been detailed



Salient Characteristics


Brand Name or Equal:  Evoqua W3T591409 Kit, RO Eon Rover ALX SCB


Fully integrated endotoxin removal filter Ultrafilter assists in preparing water or bicarbonate concentrate to meet the requirements for the production of ultrapure dialysate according to the ANSI/AAMI 11663 standard. The filter’s unique proprietary single-stage design removes bacteria, viruses, endotoxins and other contaminants greater than 0.005 micron (5 nanometers)


Multi-Stage Filtration System, including carbon filtration, reverse osmosis (RO), and ultra-filtration in one unit


Features easy-to-use controls and instant access to key parameters


Prevents RO shutdown when the inlet water has low PSI


Uses heat to disinfect rather than chemicals


Continuous flow of hot water with no time constraints


Provides single heat, storage heat


Multiple Leak Detector options, internal or remote sensor with user alert or shutdown


Color touch screen LCD control panel, clear display of operational functions


Recirculation product line


Filter and membrane access – removable back panel, machine disassembly not required


Certified to UL 61010-1, IEC 61010-1, CAN/CSA C22.2 No: 61010-1, IEC 61326-1


FDA approved 510(K) Medical Device


Must be designed to meet AAMI-Grade water standards according to ANSI/AAMI 13959 standards


Leak Detection System


Maximum Product Flow Rate at 77°F       Up to 0.4 gpm (1.5 lpm)


Inlet Temperature                                           40-104°F (4-40°C)


Inlet Pressure (Dynamic)                               Minimum: 5 psi (0.34 bars)          Maximum: 120 psi (8.3 bars)


Inlet Water Flow/Water Feed                     Minimum: 1.5 gpm (5.7 lpm)


Drain Capacity                                                   Minimum 2.0 gal/min


Total Hardness  < 10 grains (pH dependent)


Silt Density Index (SDI)  < 5


Total Chlorine    < 0.1 ppm


CART:


Rust-proof and corrosion resistant. Aluminum frame, including built-in rubber bumper guard


Large 6” dual swivel casters with locking features


Rear directional locking casters with integrated braking mechanism


Centrally located monitoring area that features pressure and temperature gauges, and sample ports with drip tray


Includes booster pump for low-pressure inlet situations


Open design to allow for easy access to filter and other areas of maintenance


Complies with ETL Tip and Threshold Testing Standards, and meets and adheres to the latest ANSI, AAMI, ISO Standards


provides hose and cord management options


All-in-one water treatment delivery system



Brand Name or Equal:  Evoqua W3T578738 Kit, Booster, MHX/WRO, Rover Family



Includes booster pump for low-pressure inlet situations



System Design


Small footprint for ease of use in vicinity of patients without interrupting patient care due to limited space in patient area


Includes installation and start up


System orientation provided


INSPECTION AND ACCEPTANCE


-The contractor shall conduct a joint inspection with the COR upon delivery


equipment.


-The contractor shall provide the VA COR a list of missing and /or damaged items


found upon inspection and have those items replaced at no cost to the Government.


-The COR shall ensure all work is completed satisfactorily prior to acceptance.


Disputes shall be resolved by the VA Contracting Officer


More opportunities from Department Of Veterans Affairs → Network Contract Office 23 (36C263)

Same awarding agency

NAICS: 811210
New
Federal
H266--Sources Sought - Equipment Testing and Program Monitoring Services of Radiology and Quality Programs - VA Black Hills Health Care System
Solicitation # 36C26327Q0137
The VA Black Hills Health Care System is conducting market research via a Sources Sought Notice to identify qualified businesses capable of providing equipment testing and program monitoring services for radiology and quality programs. The scope of work requires a Board Certified diagnostic radiological physicist to perform certification, dose rate testing, and performance monitoring on radiographic fluoroscopy X-ray equipment, as well as leak testing of sealed sources. These services will be performed at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center. The anticipated period of performance is from December 15, 2026, to December 14, 2027, with specific milestones in April and October 2027, and additional as-needed testing for new or repaired equipment. The requirement falls under NAICS code 811210 (Electronic and Precision Equipment Repair and Maintenance). Interested vendors must provide proof of capability, socio-economic status, and their SAM Unique Entity ID by December 3, 2026. The government is using this research to develop an acquisition strategy, including potential set-asides for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) or Veteran-Owned Small Businesses (VOSB). All services must comply with VHA National Health Physics Program guidelines, NRC NUREG 1556, and Joint Commission Diagnostic Imaging Standards. This notice is for market research purposes only; no proposals are being accepted, and no contract will be awarded from this specific notice.
Electronic and Precision Equipment Repair and Maintenance

POSTED

2 days ago

DEADLINE

in 6 days
View Details
NAICS: 541620
New
Federal
B510--Industrial Hygienist Service
Solicitation # 36C26327Q0134
The Department of Veterans Affairs, Network Contracting Office 23, is soliciting a firm fixed price contract for Industrial Hygienist Services at the St. Cloud VA Health Care System in St. Cloud, Minnesota. This procurement is a Service-Disabled Veteran-Owned Small Business Set-Aside under NAICS code 541620. The period of performance is scheduled from January 8, 2027, to January 7, 2032, with various option periods. The scope of work includes providing sampling, testing, and laboratory analysis for asbestos and lead, utilizing methods such as Phase Contrast Microscopy and Polarized Light Microscopy. The contractor must provide a Certified Industrial Hygienist with current certification, asbestos abatement monitoring experience, and at least three years of experience in healthcare or similarly regulated facilities. Award will be granted to the responsible offeror that is technically acceptable and offers the lowest total evaluated price. To be considered acceptable, offerors must be verified as a service-disabled veteran-owned small business in the VetCert database, provide a required staff list and individual licensing certificates, and commit to a 16-hour response time with a contingency plan. All staff must be licensed by the State of Minnesota and comply with OSHA and MNOSHA regulations. Invoices are to be submitted electronically on a monthly basis in arrears. Proposals must be submitted to Steve Ashby by December 2, 2026, at 10:00 am CST.
Environmental Consulting Services

POSTED

2 days ago

DEADLINE

in 8 days
View Details
NAICS: 531120
New
Federal
Expression of Interest - New Replacing Lease - Mitchell CBOC
Solicitation # 36C26327R0010
The Department of Veterans Affairs is seeking expressions of interest for a lease to establish a Community Based Outpatient Clinic (CBOC) in Mitchell, South Dakota. The requirement is for approximately 2,680 ABOA square feet, not to exceed 3,484 rentable square feet, with a planned occupancy date of September 2027. The VA will consider space in existing buildings, including those co-located within or directly connected to a Critical Access Hospital. This notice is a sources-sought market survey for planning purposes and not a formal solicitation for proposals. Suitable properties must meet strict go/no-go criteria, including being located within a delineated area, avoiding 100-year floodplains, and providing at least 25 parking spaces within 500 feet of the entrance. Specific parking requirements include two ADA-compliant spaces and four dedicated government vehicle spaces. The site must be within 0.30 miles of a major thoroughfare, be serviced by public transportation, and allow for ADA-compliant sidewalks. Interested parties must submit a Capabilities Statement by December 8, 2026, including evidence of SAM registration, bonding capacity for a $100,000 bid bond, and experience with similar federal or healthcare facilities. There is no set-aside status specified for this opportunity.
Lessors of Nonresidential Buildings (except Miniwarehouses)

POSTED

3 days ago

DEADLINE

in 11 days
View Details

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS