Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Government of Canada was posted on May 28, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Pre-Qualification of Open Cut General Contractors for the Elgin Mills Ductile Iron Watermain Rehabilitation Segment 1 - Bathurst Street

Closed
BT-RFPQ-3738-26International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
26350 Lynchburg, VA - CSO 70 Sewer Improvements
Solicitation # 2027-027
Cleary Construction is soliciting quotations from certified Disadvantaged Business Enterprises (DBEs) for the City of Lynchburg CSO 70 Sewer Improvements project, solicitation number 2027-027. This opportunity is open to various small business set-asides, including Veteran Owned, Service-Disabled Veteran Owned, Women-Owned, and HUBZone certified small businesses. Interested firms must submit their responses by December 4, 2026. The project is located in Virginia and is managed by primary point of contact John Connelly. The scope of work involves comprehensive sewer infrastructure improvements, including the open-cut installation of PVC and Ductile Iron Pipe ranging from 6 to 30 inches in diameter. Key technical requirements include the installation of 24-inch diameter trenchless crossings with associated launch and receiving shafts, the construction of standard and doghouse manholes, and a CSO regulator fit out. Additional site work consists of clearing and grubbing over 5,100 square yards of wooded areas, seeding, fine grading, and select tree removal. Critical operational and compliance deliverables include the implementation and maintenance of a Stormwater Pollution Prevention Plan (SWPPP), geotechnical instrumentation and monitoring, and the maintenance of flows and bypass during construction. Contractors are specifically required to obtain railroad insurance. The project also involves the abandonment of existing pipes and manholes and the construction of an outfall, with all work adhering to specified technical drawings.
Cleary Construction, Inc.

POSTED

about 3 hours ago

DEADLINE

in 28 days
NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, identified as Project No. SRP-W-134-0290, involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and extensive upgrades to the Morgans Branch Pumping Station in North Carolina. The scope of work includes installing a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. Key deliverables include the installation of mechanical and electrical systems, such as pumps, a generator, and odor control equipment, along with new gravity sewers and manholes. The project has an estimated value of 16,690,000 dollars and utilizes EJCDC standard forms for its contracting requirements. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a strong emphasis on qualifications, financial ability, and compliance with MWBE guidelines. Bidders must provide a Good Faith Efforts Form and Table A to be considered responsive. Technical requirements specify the use of Class 250 ductile iron pipe with Protecto 401 lining and adherence to North Carolina Administrative Code for sanitary sewer clearances. Contract administration is managed by the City of Belmont, with Willis Engineers serving as the project engineer. Performance and payment bonds, as well as proof of insurance, are mandatory requirements for the selected contractor.
Don Moorhead Construction, Inc.

POSTED

about 3 hours ago

DEADLINE

in 4 days

AI Contract Overview

Show more

The Region of York is seeking prequalification of general contractors for the construction of a 600mm watermain as part of the Elgin Mills Ductile Iron Watermain Rehabilitation Project, Segment 1, along Bathurst Street. All bids must be submitted electronically through the Region’s Bids and Tenders website; hard copy submissions will not be accepted. Proposals are due by 1:00:00 p.m. Eastern Standard Time on May 27, 2026, and any responses received after this deadline will be disqualified. The work involves installing new Concrete Pressure Pipe using a combination of open cut and jack and bore methods, with full details outlined in the Request for Prequalification documents. A mandatory requirement is that all applicants must hold a valid Occupational Health and Safety Management System certification as specified in Appendix A of the RFPQ; failure to meet this standard will result in immediate rejection. Questions regarding the solicitation must be submitted via the Bidding Website’s “Submit a Question” feature, and accommodation requests under the Accessibility for Ontarians with Disabilities Act should be directed to Denise French at [email hidden]. The solicitation number is BT-RFPQ-3738-26 and was posted on May 11, 2026.

General Info

Prequalification for 600mm watermain construction on Bathurst Street due May 27, 2026, with mandatory safety certification.

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Response Deadline

Deadline has passed

Posted

Solicitation

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Regional Municipality Of York
Contacts1 person available
OfficeN/A
Office AddressN/A
Contacts
Denise FrenchContracting Authority

Full Description

Show more
The Region will ONLY accept ELECTRONIC BID SUBMISSIONS submitted through the Region’s Bids and Tenders website for this Request for Prequalification. HARD COPY BID SUBMISSIONS WILL NOT BE ACCEPTED. Responses must be submitted and received by the Region no later than 1:00:00 p.m., Eastern Standard Time. BRIEF DESCRIPTION OF WORK: The proposed scope work is for the construction of the Region’s 600mm watermain for Segment 1. A combination of open cut and Jack and Bore construction is proposed for the installation of the new Concrete Pressure Pipe (CPP) watermain.For complete bid details, refer to the RFPQ documents.MANDATORY REQUIREMENT: OCCUPATIONAL HEALTH AND SAFETY MANAGEMENT SYSTEM (OHSMS) CERTIFICATION PROGRAM: Any responses received from respondents who do not meet the OHSMS certification requirements, as stated in RFPQ Particulars (Appendix A), shall be rejected from further consideration. QUESTIONS: Questions related to this RFPQ should be submitted to the Region through the Bidding Website by clicking on the 'Submit a Question' button.ACCOMMODATION REQUESTS: Accommodation requests under AODA should be directed to the Region's Procurement Representative via email to contact@example.gov

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS