Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on October 15, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Preventive Maintenance On Kohler Generator

Awarded
2110310LAS006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The project requires the contractor to bypass internal lock mechanisms and install Grade I panic bars, exterior trim, rim cylinders, strikes, and door closers at five specific locations: the B-Cafeteria, CM-Men's Dorm, CW-Women's Dorm, D-Recreation, and F-Vocational. All work must comply with NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and the Americans with Disabilities Act. Performance requirements include a site survey to verify door dimensions and fire ratings, followed by a minimum of 10 consecutive cycle tests to ensure fail-safe operation. This is a fee-for-service subcontracting opportunity set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bidders must submit a lump sum price and individual pricing per deficiency by December 1, 2026. Required submission documents include a bid sheet, a completed supplier packet with a W-9 and self-certification form, and three references for projects of similar scope. The contract is subject to various federal regulations, including FAR 52.222-4 for work hours and safety, and prevailing wage rates for building construction in Canyon and Gem Counties, Idaho, as specified in General Decision Number ID20250106. Final acceptance is contingent upon inspection by MTC at the designated point of delivery.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
Pauma Security Gate
Solicitation # 2026-27-06
Solicitation 2026-27-06 for the Valley Center Pauma Unified School District involves the fabrication and installation of automated, keypad-entry hinging steel security swing gates at entry and egress driveways in Valley Center, California. The project requires two powder-coated steel double swing gates, each 18 feet wide by 5 feet tall, and explicitly prohibits the use of chain link options. Key technical components include a mounted Knox switch with Fire Department filing, two entry remotes, gate hold timers, a mounted strobe detector for emergency vehicles, and a keypad similar to the Door King 1506-086. The contract value is capped at 1,000,000 dollars, and the award will be granted to the lowest responsive and responsible bidder. Eligible bidders must hold a California contractor's license C13 or C-61/D28 and comply with prevailing wage requirements and Department of Industrial Relations registration. The project mandates a payment bond for 100 percent of the total bid price and a DVBE participation goal of at least 3 percent. Required submissions include a comprehensive bid packet featuring non-collusion affidavits, Iran Contracting Act certification, and fingerprinting certifications. Performance must be coordinated with the Director of Maintenance and Operations, with work hours restricted to 7:00 am to 5:00 pm, Monday through Friday. Additionally, contractors must adhere to strict hazardous material standards and California Air Resources Board compliance, with the district maintaining the right to terminate the agreement upon 30 calendar days written notice.
Valley Center Pauma USD

POSTED

about 20 hours ago

DEADLINE

in 5 days

AI Contract Overview

Show more

This contract outlines the preventive maintenance requirements for a Kohler emergency diesel generator, model 250RO2D71, located in McClellan, California. The agreement mandates comprehensive monthly inspections and functional tests to ensure operational readiness, specifically focusing on oil pressure, water temperature, start times, and the automatic bus transfer switch. Monthly tasks also include verifying the integrity of the air cleaner, exhaust piping, and emergency shutdown systems, alongside detailed checks of lubrication levels, battery voltage, charging systems, belts, hoses, and coolant levels. Additionally, the main fuel tank must be inspected for water and contaminants. On an annual basis, the scope of work expands to include a full change of all oil and filters. The system must also undergo annual load testing to verify performance under stress. This maintenance program is designed to ensure the continuous reliability of the emergency power system through a combination of routine monitoring and yearly deep-service requirements.

General Info

Agency

N/A

Contract Value

$3,584.48

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

Air Station Sacramento 6037 Price Ave McClellan Ca, 95652, MCCLELLAN, CA, 95652, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Christopher A. BahnPETTY OFFICER

Full Description

Show more
The Following preventive Maintenance is to be performedon the Kohler emergency disel Generator (model # 250RO2D71) on a monthly basis. The system is to be run for a functional test to verify proper operation including oil pressure, water temperture, start time, automatic bus transfer switch (ABT), air cleaner and exhaust piping, and shutdown including emergency shutdown. Lubrication checks to ensure all oil levels are proper and there are no visible oil leaks. The batteries and are to be tested for proper voltage and water levels. They are to be visible inspected for corrosion. The charging system for the batteries is to be verified working properly. Belts are to be checked for damage, wear and proper tension. All hoses are to be checked for damage wear. The coolant levels are to be inspected, along with the radiator and all coolant hoses. Fuel level inspected in main tank along with testing for water and contaminates. The engine and generator and all included components are to be checked. On an annual Basis all filters and oil are to be changed. Also on anannual basic the system is to be load tested.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS