The FDA is seeking quotes for a Firm Fixed-Price purchase order to acquire a new benchtop environmental temperature and humidity chamber for the Winchester Engineering Analytical Center. The equipment will be used to condition regulatory samples and support medical device research. The requirement is for a brand name or equal BTL-433 chamber with a minimum capacity of 4 cubic feet, a temperature range of -20°C to 180°C, and a humidity range of 10% to 95% RH. Key technical specifications include a solid-state humidity sensor, a water leak containment and detection system, a viewing window, and a mobile cart design. The contractor must provide factory or start-up calibration with an ISO 17025 certificate and a minimum 12-month warranty for parts and labor starting from the date of formal government acceptance. The scope of work includes the delivery of the hardware, on-site installation, commissioning, and training. All deliverables must be new and meet Section 508 accessibility standards, specifically WCAG 2.0 A and AA. The contract will be awarded based on the Lowest Price Technically Acceptable (LPTA) method, with technical acceptability determined on a pass/fail basis against the salient characteristics. Delivery must be completed within 60 days of the award. Quotes are due by email to the contracting specialist by 12:00 PM Eastern Time on September 25, 2026. Submissions must include a cover letter, a detailed technical proposal with a capability statement, itemized pricing, and verification of SAM.gov registration.
General Info
Agency
NAICS
Place of Performance
85894, MA, USASet-Aside
Timeline
Response Deadline
Organization & Contact Information
Full Description
Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. The NAICS for this requirement is: 334516. The government is not obligated to make an award. The Government is not obligated to pay costs incurred by the Contractor during quote preparation and quote submission.
Background: The FDA laboratory at the Winchester Engineering Analytical Center (WEAC) uses an environmental chamber to condition regulatory samples (such as tampons, gowns, patches, etc.) at specific temperature and humidity levels before physical testing. The chamber also supports CDRH-directed research and test method development for other medical devices received by the laboratory for analysis.
Minimum Performance Requirements/Salient Characteristics:
This is a Brand Name or Equal requirement. Products other than the aforementioned are acceptable but shall meet all the salient characteristics contained in the Minimum Technical Requirements below:
All of the following system requirements are minimum requirements. Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated by the WEAC prior to purchase:
General
The contractor shall provide an environmental chamber that uniformly conditions samples across a variety of temperature and humidity settings. The chamber must meet the following specifications:
- Temperature range: at least -20°C to 180°C
- Humidity range: 10% to 95% relative humidity (RH)
- Capacity: 4 cu. Ft.
- Power: Standard power cord and plug (no hardwiring)
- Water supply: Easily accessible water supply connection
- Humidity sensor: Solid-state humidity sensor
- Leak Detection: Must have a water leak containment and detection system
- Viewing window: For visual monitoring of samples
- Interior shelf: At least one internal shelf
- Mobility: Mobile cart with space-saving footprint (lab has no bench space and limited floor space for the chamber)
- Cable port: At least one 2-inch diameter cable port with a flexible plug
- Calibration: Factory calibration with an ISO 17025 certificate, or instrument calibration at start-up with ISO 17025 certificate
- Warranty: At least one year
On-site Installation, Training and Commissioning
- On-site installation and commissioning of the Environmental Chamber
Trade and Service Specification
- All components shall be newly manufactured, not used or refurbished, and/or previously used for demonstration.
- System installation shall occur after being received at the laboratory.
- The entire system shall be warranted for parts and labor for a minimum of 12 months from date of formal government acceptance after on-site installation.
- The warranty must include unlimited telephone/e-mail support for questions regarding operation.
Additional Section 508 Requirements:
-
-
- Must meet WCAG 2.0 A and AA
- E101.2 Equivalent Facilitation (Appendix A, Application and Scoping Requirements)
- E203 Access to Functionality (Appendix A, Application and Scoping Requirements)
- E204 Functional Performance Criteria (Appendix A, Application and Scoping Requirements)
- E205 Electronic Content (Appendix A, Application and Scoping Requirements)
- 302 Functional Performance Criteria (Appendix C, Functional Performance Criteria and Technical Requirements)
- Electronic content must be accessible to HHS acceptance criteria. Checklist for various formats are available at https://www.hhs.gov/web/section-508/making-files-
-
accessible/index.html, or from the Section 508 Coordinator listed at https://www.hhs.gov/web/section-508/additional- resources/section-508-
contacts/index.html. Materials that are final items for delivery should be accompanied by the appropriate checklist, except upon approval of the Contracting Officer or Representative.
-
-
- E208 Support Documentation and Services (Appendix A, Application and Scoping Requirements)
- Chapter 6 Support Documentation and Services (Appendix C, Functional Performance Criteria
- E206 Hardware (Appendix A, Application and Scoping Requirements)
- Chapter 4 Hardware (Appendix C, Functional Performance Criteria and Technical Requirements) and Technical Requirements)
- E207 Software (Appendix A, Application and Scoping Requirements)
- Chapter 5 Software (Appendix C, Functional Performance Criteria and Technical Requirements)
-
Place of Performance:
The prospective vendor should provide insured shipping of equipment to:
U.S. Food and Drug Administration,
Winchester Engineering and Analytical Center
(WEAC)
Office of Specialty Laboratories and Enforcement Support
109 Holton Street
Winchester, MA 01890
Period of Performance:
Performance begins on the date of formal government acceptance and continues through the end of the manufacturer's warranty period.
Quotes are due by email on or before September 25 2026, by 12:00 P.M. (Eastern Standard Time) and should be sent to brandon.rafus@fda.hhs.gov.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Health And Human Services → FDA Office Of Acq Grant Svcs
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS