Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Subcontract opportunity from New York was posted on September 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Pumping Station Rehabilitation

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with an estimated value of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key deliverables include the installation of a new wet well, valve vault, pumps, a generator, and odor control equipment, as well as the demolition of existing pumps and piping. Additional requirements include the installation of new gravity sewers, manholes, stormwater facilities, and site restoration. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a strong emphasis on qualifications, financial ability, and compliance with M/WBE requirements, including the submission of Good Faith Efforts forms. Bidders must adhere to strict technical standards, such as AWWA Specification C-600 for pipelines and NEMA standards for motors. Contract administration is managed by Willis Engineers on behalf of the City of Belmont, utilizing EJCDC standard forms for agreements and payment applications. Required security includes performance and payment bonds, and insurance providers must typically maintain an A.M. Best rating of A-VII or better.
Don Moorhead Construction, Inc.

POSTED

about 5 hours ago

DEADLINE

in 1 day

AI Contract Overview

Show more

This subcontract involves the reconfiguration and rehabilitation of pumping stations for prime contractors working on Niagara Falls Water Board WWTP projects. The scope of work includes pump replacement, piping reconfiguration, electrical panel upgrades, and the structural rehabilitation of wet wells, utilizing high-capacity pumps, VFDs, and industrial valves to deliver a fully rehabilitated facility. The project requires the contractor to hold a PE license as well as mechanical and electrical contracting licenses. Interested parties must submit their responses by October 28, 2026, under NAICS code 237110.

General Info

Subcontract for Niagara Falls WWTP pumping station rehabilitation; PE license required by October 2026.

Documents

This scope was carved out of 2139286.

The full solicitation package (3 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Request for Qualifications (“RFQ”) No. 2026-01 Biological Treatment Upgrade

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNew York → Niagara Falls Water Board
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs reconfiguration and rehabilitation of pumping stations for prime contractors on Niagara Falls Water Board WWTP projects. Executes pump replacement, piping reconfiguration, electrical panel upgrades, and structural rehabilitation of wet wells. Uses high-capacity pumps, VFDs, and industrial valves. Requires PE license and mechanical/electrical contracting licenses. Delivers a rehabilitated and reconfigured pumping station.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS