Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on January 12, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

R499--STUDY TO ELIMINATE DISTRICT STEAM AT SYRACUSE VA |

Closed
36C24223R0010Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
International
Pump Optimisation and Aeration Efficiency Analysis
Solicitation # FA2253
Thames Water Utilities Limited is establishing a single-lot, sole-supplier framework agreement under solicitation FA2253 for pump optimisation and aeration efficiency services. The contract focuses on the monitoring, testing, and analysis of pumping and aeration systems across approximately 60 operational sites, encompassing roughly 200 tests during the AMP period. The primary objective is to reduce whole-life costs and improve operational performance through a structured delivery model that includes site identification, efficiency studies, and performance monitoring. The agreement will feature fixed pricing structures based on an agreed rate card and will be managed through key performance indicators to ensure strategic partnership and continuous improvement. The contract is scheduled for an initial three-year term starting May 10, 2027, with potential extensions up to a maximum of eight years, ending May 9, 2035. Eligible suppliers must demonstrate a proven track record of delivering measurable savings and innovation and must have the capacity to operate within London, the Thames Valley, and the Home Counties. Award selection is based on a 50% technical and 50% commercial weighting. The procurement process is a multi-stage procedure requiring a Pre-Selection Questionnaire via SAP Ariba by October 19, 2026, followed by an Invitation to Negotiate stage. Successful providers must also meet stringent insurance requirements, including 15 million pounds for public and products liability and 10 million pounds for professional indemnity.
Thames Water Utilities Limited

POSTED

about 2 hours ago

DEADLINE

N/A

General Info

NAICS

541330 - Engineering Services

Place of Performance

800 Irving Ave Syracuse NY 13210, NY

Set-Aside

NONE

Documents

1

36C24223R0010.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Sandra l FisherContracting Officer

Full Description

Show more
Introduction: This is a Small Business Sources Sought notice (SBSS). This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding: (1) the availability and capability of qualified small business sources; (2) whether they are small business; HUBZone small businesses; service-disabled veteran-owned small businesses; 8(a) small businesses; veteran-owned small businesses; woman-owned small businesses; or small disadvantaged businesses; and (3) their size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition. (541330) - Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. - An organization that is not considered a small business under the applicable NAICS code should not submit a response to this notice. Project Description and Requirements: The Contractor shall perform an analysis of the existing steam systems served by district steam, the on-site heating hot water boilers and their excess capacity, and available space for additional heating hot water boilers, storage of backup fuel, alternatives to the instantaneous steam domestic water heaters (such as gas-fired and/or heat pump systems), and heat pumps for serving our five co-located hot water and chilled water supplemental heating/cooling stations. The main building (building 1) is approximately 673,021 square feet. Building 16, is a 3,700 square foot facility near building 1 and should also be included in the scope of work. There are forty-nine (49) air handlers and sixteen (16) heating hot water stations in building 1. Seventeen (17) air handlers and ten (10) of the hot water stations are already served by the existing hot water boilers. There is one air handler and one hot water station in building 16, both served by district steam. All air handlers will require humidification systems. The air handlers whose preheat coils are not currently served by the existing hot water boilers and are solely served by district steam shall be connected to a new heating source, such as heating hot water and glycol or electric, as appropriate. There are three (3) steam sterilizers with backup electric steam generators that may need a water treatment system if their electric steam generators are used as the primary source of steam. There is one (1) autoclave served by steam, and it has an electric steam generator as a backup that will need treated water. Two (2) other steam fed equipment, one (1) cage washer, and one (1) steam cleaning wand that are currently served only by district steam, thus will require modifications or replacement. The existing natural gas line from the street to hospital s gas meter is likely insufficiently sized for the proposed increased gas demand, thus it s upgrade shall be included in the schematics and analysis. The Contractor shall develop schematics which will be the basis for their construction cost estimate and Life Cycle Cost Analysis. These schematics would approximate 35% of a complete project design and will be an outline for a possible follow-on Design Development and Construction Document design phases, which may be performed by a different firm. The owner will provide the selected Contractor with a list of equipment schedules (air handlers, heating hot water stations, existing boilers, domestic hot water systems, etc). The owner will also provide historical monthly steam consumption and costs, and the historical demand on the existing heating hot water boilers. The objectives of this project is for the Contractor to provide the following : First Submission: INVESTIGATIVE & FEASIBILITY. This submission shall be submitted to the Contracting Officer thirty (75) calendar days after receipt of the Notice to Proceed (NTP). This submission includes investigative services and the development of the thermal energy load profiles for the Syracuse VA campus, existing hot water boiler load and capacity, and humidification load. The A/E shall also develop the load profile for the five heating and cooling stations for consideration for use of heat pumps to transfer energy between the loops. The A/E shall show proposed locations of all new equipment and existing equipment served by the proposed concept. The A/E shall perform a preliminary Life Cycle Cost Analysis and provide a written narrative regarding the feasibility of disconnecting from district steam. VA review time is expected to be no more than fourteen (14) calendar days for this First Submission submittal. Second Submission: CONCEPTUAL DESIGN. This submission shall be submitted to the Contracting Officer sixty (75) calendar days after receipt of VA s comments on the first submission. This submission includes a conceptual plan and location for the equipment, such as heating hot water boilers, heat pumps, and low-pressure steam humidification boilers or other humidification alternatives. The plan shall also provide proposed pipe routing from thermal generating equipment to loads (i.e. air handlers, hot water stations, etc). Consider electric steam generators for sterilizers, cage washers, and kitchen steam kettles. The calculated natural gas demand shall be used to determine the size of the gas service. The existing gas main between the building meter and the east side of Irving Avenue is already at capacity, thus the cost of an upgraded gas service shall be included. The A/E shall provide a life-cycle cost analysis based on the proposed concept. Include estimated campus-wide Greenhouse Gas Emission reductions due to the proposed concept compared to the current sources of energy. The A/E shall consider all comments generated by the first review in their second submission and provide an estimate of probable construction cost and an updated Life Cycle Cost Analysis. VA review time is fourteen (14) calendar days for the Second Submission submittal. Final Submission: Final feasibility study narrative and Life Cycle Cost Analysis, schematics, and probable construction cost shall be submitted to the Contracting Officer thirty (30) calendar days after receipt of the VA s second submission comments. Provide 2 paper copies of the report. On a DVD, or via ftp site, provide an electronic version in PDF format. Anticipated Period of Performance: Total Design Period shall be two hundred and eight (208) calendar days from Notice to Proceed. Other important considerations: The Contractor shall have prior experience and demonstrated success in the areas of energy studies. Respondents shall have demonstrated the capabilities to perform feasibility steam studies and conceptual drawings for quality improvements that are valid and reliable and a cost savings. Information Sought: The tailored response to this Small Business Sources Sought notice should describe the requested information below. Respondents must provide, as part of their response, information concerning: a) Staff expertise, including their availability, experience, and formal and other training; b) Current in-house capability and capacity to perform the work at the scale/magnitude of the feasibility study and schematic design; c) Corporate experience and management capability; d) Prior completed projects of similar size and nature that involve maintaining and managing multiple, multi-faceted activities concurrently at the highest level of professional and scientific quality; e) Examples of prior completed Government contracts, references, and other related information; and f) Any applicable Governmentwide Acquisition Contracting (GWAC) vehicle information (example: GSA Schedule and SIN). Information Submission Instructions: Interested qualified small business organizations should submit a tailored capability statement for this requirement. The cover page must include the following: UEI number Organization name Organization address Size and type of business (e.g., SDVOSB; VOSB; SB;8(a), HUBZone, etc.) pursuant to NAICS code 541330. Technical point(s) of contact, including names, titles, addresses, telephone, and e-mail addresses. All Capability Statements sent in response to this SMALL BUSINESS SOURCES SOUGHT notice must be submitted electronically (via e-mail) to contact@example.gov, Contract Specialist, in MS Word, or Adobe Portable Document Format (PDF), no later than 10:00 AM EST on February 02, 2023. Responses should not exceed 5 single-sided pages (including the cover page, all attachments, resumes, charts, etc.) presented in single-space and using a 12-point font size minimum, that clearly details the ability to perform the aspects of the notice described above. Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation will be published on SAM.gov. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 334516
New
Federal
6550--Sources Sought: Tuberculosis Testing Reagents and Consumables for the Buffalo VA Medical Center. In support of the Tuberculosis (TB) Testing Program
Solicitation # 36C24227Q0095
The Department of Veterans Affairs, VISN 02 Network Contracting Office, has issued a Sources Sought Notice under solicitation number 36C24227Q0095 to identify qualified sources for tuberculosis testing reagents and consumables for the Buffalo VA Medical Center. This request is for information and planning purposes only and does not constitute a formal solicitation. The government is seeking a domestic source capable of providing FDA-cleared reagents, test kits, controls, and processing materials that are compatible with the T-SPOT TB testing platform and methodology. All items must be delivered in original manufacturer packaging with sufficient shelf life and meet all manufacturer specifications for accuracy and performance within an accredited clinical laboratory environment. Interested respondents must submit their capabilities via email to the contracting officer by November 12, 2026. Submissions must include the company's Sam.gov Unique Entity ID, business size status relative to NAICS code 334516, and details regarding whether they are a manufacturer or distributor. The government is specifically looking for information on business representations such as SDVOSB, VOSB, Hubzone, and WOSB status, as well as any existing federal contracts through GSA, NAC, or NASA SEWP. While general pricing is encouraged for market research, it will not be used for award evaluation. Responses must demonstrate clear evidence that any equivalent products meet all salient characteristics and specify if the items are manufactured within the United States.
Analytical Laboratory Instrument Manufacturing

POSTED

about 5 hours ago

DEADLINE

in 14 days
View Details
NAICS: 238290
New
Federal
J039--561A4-25-500 Elevator Repair Building 6 and 53
Solicitation # 36C24226R0097
Solicitation 36C24226R0097 is a Request for Proposal issued by the Department of Veterans Affairs for the emergency upgrade and modernization of four elevators at the VA New Jersey Healthcare System Lyons Campus, specifically targeting one passenger elevator in Building 6 and one service and two passenger elevators in Building 53. The scope of work requires the contractor to provide all labor, materials, and supervision to install non-proprietary microprocessor-based control systems, new geared machines, car operating panels with braille markings, hall fixtures at ADA compliant heights, and complete shaft wiring. All work must adhere to current safety codes, including fire recall features and door lock monitoring, and comply with the Davis-Bacon Act for prevailing wage rates. This procurement is a Service-Disabled Veteran-Owned Small Business set-aside under NAICS code 238290. To be eligible, the prime contractor must be a licensed elevator maintenance company with a full-time mechanic on staff and a clean safety record, certifying no more than three serious, one repeat, or one willful OSHA or EPA violation in the last three years. Proposals are evaluated based on technical capability, past performance, and price, with a requirement to submit a current Experience Modification Rate (EMR) and certifications for the Buy American Act and limitations on subcontracting. Following several extensions to accommodate requests for information, the final deadline for proposal submission is 1:00 PM on Thursday, October 29, 2026.
Other Building Equipment Contractors

POSTED

about 5 hours ago

DEADLINE

in 22 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS