RADIO FREQUENCY (RF) EMANATIONS TESTING FOR A SHIELDED ROOM

Closed
FA8621-23-C-XXXXFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541330 - Engineering Services

Place of Performance

Wright Patterson AFB, OH, 45433, USA

Set-Aside

NONE

Documents

1

Sources Sought Synopsis for RF Emanation Testing for Shielded Room

PDF, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA8621 Aflcmc Wnsk Sims
Contacts2 people available
OfficeWRIGHT PATTERSON AFB, OH, 45433-7249, USA
Office AddressWRIGHT PATTERSON AFB, OH, 45433-7249, USA
Contacts
Jenifer Moore
Dominic McClung

Full Description

Show more
The Air Force Life Cycle Management Center, Simulators Division (AFLCMC/WNS), requires Radio Frequency (RF) testing for a 100 square foot room. This testing is required to certify the room to operate without restricting the use of electronic devices within a three-meter perimeter outside of the room. The contractor shall test and report if the current rFOIL shielding satisfies both below standards for shielding effectiveness: The Air Force standard for shielding effectiveness (attenuation) for shielded enclosures and global shielding is 50 dB (plus an initial 10-dB allowance for life-time degradation); and The standard for equipment performing an instrumented test in this environment shall be performed IAW National Security Telecommunications and Information System Security Advisory Memorandum (NSTISSAM/TEMPEST 1-93). These standards are specified in Air Force Systems Security Instruction (AFSSI) 7702, paragraph 10.4.5. In addition, the contractor shall: Hold a SECRET clearance or higher; Be capable of sending a visit request via Defense Information for Security System (DISS) web application; Acquire base access to Wright-Patterson Air Force Base, OH; Possess mobile calibrated testing equipment capable of measuring emanations outside of a 100 square foot area shielded room; Transport testing equipment with set-up and break-down. Be certified by the NSA TEMPEST Certification Program (TCP) to perform the Certified Test Service Program; Author a test plan formatted IAW paragraph 2 of the Field Test Memorandum issued by the NSA; After Government approval of the test plan, conduct a test IAW the above outlined requirements; and; Provide final report of test results.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS