Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on April 18, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

RECOVERY-ROOFING IDIQ TASK ORDER

Awarded
MPLS021010OFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238160
New
SLED
GSW-27-40-01 GSW Student Success Center Flat Roof Project
Solicitation # GSW-27-40-01
Georgia Southwestern State University is soliciting sealed bids for the GSW Student Success Center Flat Roof Project (GSW-27-40-01) located at 240 Edgewood Avenue, Americus, Georgia. The scope of work involves a single prime contract for the installation of a Thermoplastic-Polyolefin (TPO) roofing system, including selective demolition, cast stone masonry, sheet metal flashing, and a lightning protection system compliant with UL 96A and LPI 175 standards. All roofing materials must meet FM Approvals 4450 or 4470 certifications and adhere to specific ASTM weathering and impact resistance standards. Bids must be submitted in a sealed envelope to Sierra Harvey, Director of Purchasing, by November 19, 2026, at 2:00 p.m. local time. Submissions must include a bid bond of at least 5 percent of the total bid; the successful contractor will be required to provide performance and payment bonds equal to 100 percent of the contract sum within 10 calendar days of award. While the contract is based on a lump sum price, the university may award the contract to a bidder other than the low bidder based on a review of bidder qualifications. The contractor is responsible for coordinating all work to maintain roofing warranties and must provide a Letter of Findings Certificate from Underwriters Laboratories or an LPI-IP certificate upon completion.
Georgia Southwestern State University

POSTED

about 20 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

This contract, issued under the American Recovery and Re-Investment Act of 2009 to ensure transparency and accountability, involves a task order for roof replacement at three buildings (2059, 2060, 1208) located at Lackland Air Force Base, Texas. The task order is governed by the terms of the Basic Contract Number FA3047-08-D-0030 and requires the contractor to supply all necessary labor, materials, tools, transportation, equipment, and other incidentals to complete the specified work. The solicitation number was updated from MPLS021010O to MPLS021011O, consolidating various line items under one award. The total contract award amount is $62,323.17, with individual allocations of $7,762.40 for the combined task order, $520.44 for building 2059, and $54,040.33 for building 1208. The project falls under NAICS code 238160, indicating roofing work, and is managed by the Department of Defense at the JBSA Lackland office. Key points of contact include Contract Specialist John S. Bandy and Contracting Officer Ann W. Coleman, ensuring oversight and communication throughout the contract period.

General Info

Task order for roof replacement at Lackland AFB under contract FA3047-08-D-0030 totaling $62,323.17.

Contract Value

$74,873.34

NAICS

238160 - Roofing Contractors

Place of Performance

BUILING 2059, LACKLAND AFB, TX, 78236, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts2 people available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
John S BandyContract Specialist
Ann W ColemanContracting Officer

Full Description

Show more
In compliance with the transparency and accountability requirements associated with the supplemental appropriations provided by the American Recovery and Re-Investment Act of 2009, Pub.L. 111-5, the Government posts this AWARD notice of intent to issue a task order under an established IDIQ Contract with Galindo Roofing Services. This Task Order is issued pursuant to the terms and conditions of the Basic Contract Number FA3047-08-D-0030 and any modifications thereto. Contractor shall provide all labor, materials, tools, transportation, equipment and any incidentals necessary to complete the line items associated with the specified project. Project will consist of roof replacement Building 2059. CHANGE THE SOLICITATION NUMBER FROM MPLS021010O TO MPLS021011O. THIS SOLICITATION WAS COMBINED WITH MPLS061011M AND MPLS051011N UNDER DELIVERY ORDER 0007.

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 811310
New
Federal
Aviation Support Equipment Load Testing
Solicitation # F2MT2M6146AQ01
This Sources Sought Notice, solicitation number F2MT2M6146AQ01, is a market research effort to identify qualified sources capable of providing aviation support equipment load testing and maintenance for the 433rd MXS/AMXS at Joint Base San Antonio-Lackland, Texas. The scope of work involves non-personal services including annual preventive maintenance inspections, load tests, certification, and both scheduled and unscheduled repairs to ensure the safe operation of aircraft support equipment. All services must adhere to OSHA Standards 1910 and 1926, ANSI Standards B30.16 and B30-5, and applicable Air Force Instructions and Technical Orders. Key deliverables include an initial annual preventive maintenance schedule, certification reports due within two workdays of completion, and repair estimates provided within 48 hours of an initial survey. Performance requirements specify that standard preventive maintenance must be completed and equipment returned within 48 hours of pickup, while approved repairs must be returned within three business days. Interested vendors must submit their response, including company details, CAGE code, and a statement of capability with product literature, to Dalwyn Corporan-Polanco by 10:00 AM CDT on October 20, 2026. This notice is for research purposes only and does not constitute a solicitation or a promise to issue one.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

5 days ago

DEADLINE

in about 1 hour
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS