Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Remove/Replace Utility Pole-Encroachment Permit 725-6US-1083

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Pacific Bell Telephone Company dba AT&T California plans to remove and replace two utility poles, #4650295E and #4650296E, situated within the California Department of Transportation right of way along State Route 150 at Post Mile 3.84 near Rameli Ranch Road in the City of Ventura. The project includes the installation of a ground bed adjacent to pole #4651227E, requiring the excavation of a 10-square-foot area on the shoulder to bury a #6 AWG bare copper ground wire connecting to two newly installed 5/8-inch diameter, 8-foot copper grounding rods. These rods will be pneumatically driven into the ground with a minimum of 42 inches of cover, and the excavation for the ground bed will not exceed 55 inches in depth, 12 inches in width, or 10 feet in length. Temporary traffic control measures will be implemented to ensure safety during construction, and no existing public utilities will be relocated or disturbed. No additional right-of-way acquisition is required, and all work will remain within the existing Caltrans right of way. The project is being managed under Encroachment Permit 725-6US-1083, with Mojgan Abbassi, Senior Environmental Scientist Specialist at Caltrans District 7, serving as the primary point of contact.

General Info

Replace two utility poles, install ground bed with two copper rods, no utility relocation, within Caltrans right of way.

Agency

California → Caltrans, District 7 - Los Angeles

Place of Performance

Ventura, CA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Caltrans, District 7 - Los Angeles
Contacts1 person available
OfficeN/A
Organization / Agency
California → Caltrans, District 7 - Los Angeles
Office AddressN/A
Contacts
Mojgan AbbassiSenior Environmental Scientist Specialist

Full Description

Show more
Pacific Bell Telephone Company dba AT&T California (AT&T) proposes to remove and replace poles #4650295E and #4650296E located within CALTRANS right of way along State Route (SR-)150 at Post Mile (PM) 3.84 – Rameli Ranch Road, as well as to perform associated temporary traffic control activities in the City of Ventura, Ventura County. The work will also include the excavation of 10 square feet of shoulder to install a ground bed adjacent to existing pole #4651227E. The ground bed will include the direct burial of ground wire (#6 AWG bare copper wire) from SCE/AT&T jointly owned pole interconnected to two new 5/8" diameter, 8-ft long, copper grounding rods. Rods to be pneumatically driven in the ground with 42" minimum cover. Excavation will have a maximum depth of 55 inches, a maximum width of 12 inches, and a maximum length of 10 feet. No public utilities will be relocated, and no new right-of-way will be acquired for the project.

Similar Contracts

Same NAICS industry code

NAICS: 237130
New
Federal
USFK C4I Communication Tower and Facility Maintenance CY27
Solicitation # W91QVN26QXXXX
This firm-fixed price non-personnel services contract, solicitation number W91QVN26QXXXX, provides communication tower and facility maintenance for the 41st Signal Battalion C4I mission support in South Korea. The scope of work includes physical and visual inspections of metal surfaces for structural integrity, maintenance of bonding, grounding, and lightning protection systems, LED replacement for beacon and side marker lights, and interior and exterior repairs for C4I communication shelters. Performance is required across multiple sites, including Papyongsan, Yongsan TCF, Osan Bucket, Highpoint, and CP Walker AFN FM. The base period of performance is 12 months from the date of award, with funding provided by the Republic of Korea Ministry of National Defense (ROK MND). Award will be made on an all-or-none basis to the responsible offeror submitting the lowest price that is technically acceptable. Technical acceptability is evaluated on a pass/fail basis, requiring a complete technical package and compliance with the Performance Work Statement. All price proposals must be submitted in Korean Won. The contractor must provide key personnel, including an Information and Communication Engineer and a CQCSM/Safety Manager with specific education and experience requirements. Mandatory qualifications include an Information and Communication Construction License and an Electrical Construction License. The contractor is also required to adhere to strict security protocols, including AT/OPSEC compliance for foreign performance and the safeguarding of Controlled Unclassified Information.
0411 Aq Hq Contract Augmented

POSTED

about 19 hours ago

DEADLINE

in 29 days
View Details
NAICS: 237130
New
SLED
Refurbishment Of Existing On Load Tap Changer At Adobe Creek Substation - AC21
Solicitation # RFQ199445
The City of Palo Alto Utilities is seeking a contractor under RFQ199445 to refurbish the existing TLH-21 On Load Tap Changer (OLTC) on an Allis Chalmers 15MVA transformer at the Adobe Creek Electric Substation (AC-21). This project is critical to mitigating reliability risks for customers served by the Adobe Creek, Colorado, and Maybell substations, as the current transformer is offline due to mechanical failures and oil migration issues. The scope of work includes replacing the TLH-21 LTC with a certified re-manufactured component, draining and filling the LTC and main tanks, re-sealing barrier boards and pass-through studs, replacing the 60KV SMD fuse holder and radiator valves, and performing comprehensive pressure and vacuum testing. The City mandates the use of Allis Chalmers TLH-21 components and will not accept alternate substitutions. The contract will be awarded to the lowest responsive and responsible bidder based on the lowest Base Bid. Qualified bidders must demonstrate sufficient experience, capacity, and a satisfactory performance history, and must provide proof of registration with the California Department of Industrial Relations. As a public works project, the contract is subject to California prevailing wage laws and requires compliance with the City's Environmental Purchasing Policy. Key administrative requirements include monthly invoicing in arrears with a 30-day payment term, the submission of insurance certificates to the purchasing support email, and the provision of bond forms if the contract sum exceeds 25,000 dollars. Delivery terms are F.O.B. Palo Alto, Freight Prepaid, and the City remains responsible for de-energizing and grounding the transformer to ensure a safe work area.
Utilities

POSTED

about 23 hours ago

DEADLINE

in 15 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS