REPLACE STEAM AND CONDENSATE PIPELINES, F-202626 & 202651
Active
FederalContract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of The Navy → Navfac Far EastView Agency
NAICS
N/A
Place of Performance
USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Organization & Contact Information
Show more
AgencyDepartment Of The Navy → Navfac Far East
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Full Description
Show more
The scope of work were based on the information and analysis obtained by BOSC DG Technical Consultation dated August 2021. Project will perform the following: For the under ground steam pipeline: (1) Replace with new 6-in. A53B Schedule 40 Galvanized Coated Roll Groove Welded Carbon Steel SRL Pipe under ground pipeline approx. 4200-lf steam outlet and condensate inlet pipeline complete with all fittings, valves, and all required accessories, (2) Replace with new foam insulation and new stainless steel cladding approx. 2100-lf complete with sealants and all required accessories on the steam outlet piping assembly, (3) Replace with new foam insulation and new stainless steel cladding approx. 2,100-lf complete with sealants and all other required accessories on the condensate inlet piping assembly. For the above ground steam pipeline: (4) Replace with new 6-in. A53B Schedule 40 Galvanized Coated Roll Groove Welded Carbon Steel SRL Pipe above ground pipeline approx. 460-lf steam outlet and condensate inlet pipeline complete with all fittings, valves, and all required accessories, (5) Replace with new foam insulation and new stainless steel cladding approx. 230-lfcomplete with sealants and all required accessories on the steam outlet piping assembly (6) Replace with new foam insulation and new stainless steel cladding approx. 230-lf complete with sealants and all required accessories on the steam condensate piping assembly, For underground trenching/ excavation: (7) Saw-cutting portion of secondary road, (8) Trenching / excavation work for underground utilities, include backfilling of trench with sand cushion and excavated earth, and (9) Restoration of affected secondary concrete roads.
More opportunities from Department Of The Navy → Navfac Far East