Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on May 13, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT - Restroom Addition

Closed
N0016421SNB56Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Department Of Commerce Nist

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 236210
New
Federal
Sources Sought - POST TEST LITHIUM BATTERY STORAGE
Solicitation # N00167-27-RFPREQ-CD-102-0002
The Naval Sea Systems Command Naval Surface Warfare Center Carderock Division is conducting a sources sought effort for the construction of a Post-Test Lithium Battery Storage Facility in West Bethesda, Maryland. This project, classified under NAICS code 236210 for Industrial Building Construction, involves the creation of a storage area featuring a non-flammable single-pitch sloped roof, a perimeter fence with a gate, 3-hour rated firewalls, and concrete walls for large battery storage. Additional requirements include low-voltage outlets, pole-mounted LED flood lighting, and a dedicated forklift access road. The effort must be completed within 210 days of the award and adhere to Unified Facilities Guide Specifications and other stringent technical criteria. This notice is not a request for proposal, and no award will be made directly from this notice. Interested small and large businesses must submit a capability statement and a Rough Order of Magnitude by 1700 EST on 18 November 2026 to Heather Valiga. The government will use these responses to determine the future acquisition strategy. Because the project is located on a secure military installation, all personnel must obtain proper clearances and credentials. Key deliverables include an Activity Hazard Analysis and a detailed schedule due within five days of the pre-construction meeting, as well as a personnel list provided seven days before the start date.
Nswc Carderock

POSTED

1 day ago

DEADLINE

in 29 days
NAICS: 236210
New
SLED
Arrowhead Regional Medical Center Lot 1 Parking Structure
Solicitation # 2026010330
The County of San Bernardino is soliciting the construction of the Arrowhead Regional Medical Center Lot 1 Parking Structure located at 400 North Pepper Avenue in Colton, California. The project consists of a post-tensioned, cast-in-place structure spanning up to 500,000 square feet across six levels, providing up to 1,600 parking spaces. Key design elements include a finished exterior with an architectural mesh facade on the first floor, two banks of two elevators, and the installation of photovoltaic panels on the top level. The facility will be restricted to employees via badge access and will feature security enhancements such as LED lighting, emergency call boxes, security cameras, and locked gates. The project must comply with the California Building Code, the Americans with Disabilities Act, the 2022 California Building Energy Efficiency Standards (Title 24), and the California Green Building Standards Code (CALGreen) for electric vehicle charging stations. Environmental mitigation includes a landscape plan to offset the removal of approximately 51 trees. To maintain parking capacity during construction, a temporary surface parking lot will be operated at 1351 West Valley Boulevard with shuttle services provided to the campus. The project has undergone CEQA review, resulting in a Mitigated Negative Declaration confirming that the project will not have significant environmental impacts provided mitigation measures are implemented.
San Bernardino County

POSTED

1 day ago

DEADLINE

N/A

General Info

NAICS

236210 - Industrial Building Construction

Place of Performance

IN

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

special-notice

Notice updated

Response deadline changed from Apr 29, 2021 to May 28, 2021. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Nswc Crane
Contacts1 person available
OfficeCRANE, IN, 47522-5001, USA
Office AddressCRANE, IN, 47522-5001, USA

Full Description

Show more
N0016421SNB56 - REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT - Restroom Addition - PSC Z2QA - NAICS 236210 Issue Date: 04/08/2021 - Closing Date: 04/29/2021 - 2:00 PM EDT The Government is issuing this RFI/sources sought announcement as part of market research for construction of a single occupancy ADA/ABA unisex restroom facility that will be located inside an existing building at the Naval Surface Warfare Center, Crane Division, (NSWC Crane) located at Naval Support Activity (NSA), Crane, IN. The scope of this effort is listed below by trade. Existing space was a previously demoed restroom with approximate dimensions 12 wide x 30 deep. The goal of this project is to isolate a smaller space (approx. 12 wide x 8 deep) to create a single occupancy unisex restroom that abides by ADA specifications and fits within the overall existing space. Utilities exist, but will need retrofitted, repaired, or replaced to support this addition. Restroom Construction: There are 2 options for restroom construction: Option #1 - Stick built construction. Construct 3 5/8 x 9 high metal stud walls approx. 40lf. Install approx. 470sqft of 5/8 drywall (Hang, tape, and finish). Install a suspended ceiling (approx. 100 sqft) with 2 x 2 ceiling tiles. Patch and repair concrete floor as needed. Provide VCT or epoxy flooring (approx. 100 sqft.) Provide vinyl cove base around interior and exterior of the restroom. Paint all new walls 2 coats. Install ADA grab bars Install a painted 3'0 x 7'0 hollow metal entry door with appropriate ADA lock and hardware with knock down metal jamb New restroom shall be furnished with a mirror, unisex restroom sign, soap dispenser, paper towel dispenser, new trash can, toilet paper holder, and waste receptacle for feminine hygiene disposaL Option #2 - Pre-fabricated construction and assemble onsite. Purchase a pre-fabricated restroom unit that is the appropriate size to meet ADA/ABA specs. Assembly the unit onsite and connect all utilities. Pre-fabricated restroom unit shall include all finish components listed in option #1 that meet and/or exceed quality, capability, and ADA specifications. Pre-fabricated unit must have transferable warranty to the government via the manufacture. The following shall apply regardless of either option listed above: Plumbing: There was a restroom facility in this location prior. There are old plumbing flanges, water lines, and vents that need to be demolished. A new 6 sewer line will need to be run approx. 50 to replace the existing damaged cast iron line where it will connect to existing PVC. Excavation for new sewer line consists of approx. 20 open excavation, 15 under truck dock crawlspace, and 15 under existing slab excavation to be reduced to 4 PVC at the flange. A 6 cleanout shall be installed and capped off at grade located nearest to the existing dock, where not to impede travel and install a centralized floor drain. A new 1.5 water line will need to be run overhead from the meter approx. 120 inside the building to the new restroom location area. A 2 pressure regulator and isolation valves plumbed in parallel with the restroom feed shall be installed near the meter. Plumbing fixtures include: ADA toilet ADA wall mounted sink On demand water heater Drinking fountain Utility sink Drinking fountain and utility sink will be located outside of the restroom footprint. Electrical: Electrical components that need installed and powered are: On demand water heater sized appropriately for a single occupancy restroom Wall mounted heater sized appropriately for a single occupancy restroom 1 - 2'x4 LED lay-in ceiling fixture 1 - Exhaust fan 1 - 110V/20A GFCI outlet Exhaust fan and LED light will be on a single motion sensor switch. The main panel where power will be pulled from is approx. 25. All wiring will be run in EMT conduit from panel to restroom. HVAC: HVAC installed components shall include: Wall mounted electric heater Exhaust fan Exhaust ductwork Exterior louver All required ancillaries Fire: Sprinkler heads exist within the new restroom area, and will need routed appropriately and 1 head dropped thru the suspended ceiling inside the restroom. Additional Notes: Existing fire suppression lines are thought to contain lead-based paint. No other lead-based paint coatings are suspected. There are no known asbestos containing material. Uncovered gravel material laydown/staging area is available for use during construction. No restroom facilities are available for use during construction. NSWC Crane is requesting the following information for planning purposes only and will be used for planning associated budget, schedule, and requirements with our Strategic Program sponsors. Estimated design cost Estimated construction cost for option #1 and #2 Estimated project duration All interested parties are encouraged to submit company and product literature, a white paper no longer than 5 pages, and/or other pertinent information, such as description of work, estimated project duration with potential project risks identified, a statement of current availability, summary of prior experience, and a budgetary estimate. Responses to the Market Survey shall include the following: Submitter's Name Street Address, City, State, Zip Code Business Size Point of Contact (POC) POC Telephone Announcement Number: N0016421SNB56 Contractors must be properly registered in the Government System for Award Management database (SAM). Contractors may obtain information on SAM registration and annual confirmation of requirements by calling 1-866-606-8220, or via the internet at www.sam.gov. At the current time, NO FUNDING IS AVAILABLE for contractual efforts. This RFI/sources sought does not constitute an Invitation for Bids (IFB), a Request for Quote (RFQ), or a Request for Proposal (RFP) and it should not be construed as a commitment of any kind by the government to issue a formal solicitation or ultimately award a contract. The US Government is in no way liable to pay for or reimburse any companies or entities that respond to this announcement. Any costs incurred by interested companies in response to this announcement will NOT be reimbursed. Market Survey information shall be submitted to NSWC Crane Acquisition POC Ms. Diane Bright, diane.bright@navy.mil , cc: kristi.price@navy.mil. For confirmation, you can contact Diane Bright by phone at 812-227-0765. If any part of the submittal is classified, please contact the POC for appropriate submission information. All information marked as proprietary information will be safeguarded to prevent disclosures to non-government personnel and entities. Your interest in the response is appreciated. AMENDMENT 0001: The purpose of this amendment is to extend the closing date from 04/29/2021 to 05/28/2021 to allow additional time for industry response. All other terms and conditions remain unchanged.

More opportunities from Department Of Defense → Nswc Crane

Same awarding agency

NAICS: 811310
New
Federal
EVALUATION/REPAIRS
Solicitation # N00016427Q0006
Solicitation N00164-27-Q-0006 is a sole source, firm fixed price procurement issued by the Naval Surface Warfare Center Crane Division for engineering services to support five AN/SLQ-32(V)4 G4DSP-XD3 multiprocessor cards. The primary objective is to perform evaluation diagnostics, failure analysis, and data extraction on non-working processing units to determine if they are repairable or beyond economic repair. Key technical requirements include salvaging Northrop Grumman running scripts and operational binary scripts from non-volatile memory, as well as mapping hardcoded IP schemes and network connection profiles. The government intends to negotiate exclusively with Abaco Systems due to the items being peculiar to one manufacturer, although other responsible sources may submit capability statements for consideration. The contract requires strict adherence to MIL-STD-129 for shipping and marking, NIST SP 800-88 Rev. 1 for media sanitization, and DoDI 8582.01 for the security of non-DoD information systems. Contractors must be registered in the System for Award Management and comply with Cybersecurity Maturity Model Certification (CMMC) requirements under DFARS 252.204-7021. Deliverables include software test reports, computer software products, and system security plans. Invoicing must be processed through the Wide Area WorkFlow (WAWF) system. Offers are due by 4:00 PM Eastern Time on October 26, 2026, and should be submitted electronically to the primary point of contact, Trista Ray.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS