Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 26, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Project XUMU 243207, Engineering Study, Study Launch Facilities (LFs) 9 and 10, Vandenberg SFB, CA

Awarded
243207Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Fire Alarm engineering for Lewis County
Solicitation # 2026-RFQ-040
Lewis County is soliciting qualifications under solicitation 2026-RFQ-040 for a professional engineering firm to provide comprehensive design and engineering services for fire alarm systems. The project encompasses several County-owned facilities, including the IT Building, Historic Courthouse, Health Building, and Lewis County Jail. The selected firm will be responsible for conducting on-site evaluations to determine the remaining useful life of existing systems, assessing code compliance with NFPA 72, IBC, and IFC standards, and developing bid-ready construction drawings and technical specifications. All designs must be stamped by a licensed electrical engineer familiar with Washington State fire alarm requirements and must integrate smoothly with existing infrastructure to ensure standardized maintenance and operations. Proposals are due by November 10, 2026, via the OpenGov platform and will be evaluated by a committee of at least three County employees using a points-based system. The evaluation criteria are equally weighted at 20 percent each across four categories: firm qualifications (including NICET certifications and licensed engineer availability), responsiveness and capacity to begin work within 30 days, regulatory compliance and permitting records, and the clarity and detail of blueprint designs. Applicants must provide a statement of qualifications, three public agency references from the last five years, and resumes of key personnel. The contract is administered by Matt Patana, Capital Infrastructure Specialist, based in Chehalis, Washington.
Capital Infrastructure

POSTED

about 13 hours ago

DEADLINE

in 21 days
NAICS: 541330
New
International
Provision of Consulting Services for Regional Basement Flooding Mitigation Program Strategic Plan
Solicitation # P-1353-26
The Region of Halton is soliciting proposals for a consulting firm to conduct a comprehensive review of its existing Basement Flooding Mitigation Program and develop a three-year Strategic Plan. The primary objectives are to reduce basement flooding risks, enhance wastewater system resilience, and decrease wet-weather flows. The project is expected to be completed within nine months of kick-off and includes key deliverables such as a current-state assessment report, a prioritization framework for initiatives, a final strategic plan with an implementation roadmap, and a performance measurement and reporting framework. The selected consultant must provide a Project Manager with PMP certification or equivalent credentials. The contract will be awarded based on a scoring system where the technical proposal accounts for 80 points and the cost proposal accounts for 20 points. Proponents must achieve a minimum technical score of 70% to be considered for award and may be invited to a 30-minute presentation. Mandatory submission requirements include a technical proposal, a signed Vendor Code of Conduct Acknowledgement Form, and a cost proposal submitted via the online bidding system by November 12, 2026. The agreement is governed by a modified Standard Agreement and Supplementary Conditions, requiring the consultant to maintain specific insurance coverages: 5 million dollars for Commercial General Liability, 2 million dollars for Automobile Liability, and 2 million dollars for Professional Liability. Additionally, the consultant must provide a WSIB clearance certificate upon award and with every monthly electronic invoice. All produced materials remain the sole property of the Region of Halton, and deliverables must comply with the Ontario Building Code and the Accessibility for Ontarians with Disabilities Act.
Region of Halton

POSTED

about 15 hours ago

DEADLINE

in 23 days
NAICS: 541330
New
SLED
REQUEST FOR PROPOSAL (RFP) STAR Centre Energy Modernization Project Energy Audit
Solicitation # BPM059233
The City of Havre de Grace is seeking proposals for a comprehensive energy audit of the STAR Centre, the city's largest public building, as the first phase of an Energy Modernization effort. This grant-funded project, supported by the Maryland Energy Administration Local Government Energy Modernization Program Grant 52-600796, requires a contractor to perform an ASHRAE Level 1 walkthrough Energy Audit. The scope includes documenting baseline operating conditions, analyzing utility billing data, evaluating eligibility for utility rebates, and providing a detailed report of energy efficiency measures for lighting, HVAC, and building envelope weatherization. Additionally, the contractor must develop a Monitoring Based Commissioning Plan (MBCx) to support future energy management and continuous performance monitoring. The contract will be awarded based on the best value to the city, considering the technical approach, cost factor, and the bidder's experience. Eligible offerors must be established businesses with at least five years of industry experience and must be in good standing with the State of Maryland, Harford County, and the City of Havre de Grace. Required submission documents include a Maryland Business License, a Certificate of Good Standing, an IRS W-9, and evidence of insurance covering General Liability, Workers' Compensation, and Errors and Omissions. Proposals must be submitted electronically via Beacon Bid by November 23, 2026. The selected vendor must be able to complete the audit and deliverables within a 60-day period, with a final project completion deadline of February 5, 2027. Payment will be made upon the successful completion of services, with the possibility of progress payments based on a satisfactory schedule.
City of Havre de Grace

POSTED

about 15 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

Project XUMU 243207 is a Request for Qualifications for architectural and engineering services to conduct a comprehensive engineering study of Launch Facilities 9 and 10 at Vandenberg Space Force Base, California. The selected Architect-Engineer firm will perform field investigations to evaluate concrete structures, identify underground utilities, and analyze groundwater infiltration and penetration within the silos. The final deliverable must include documentation of the current structural state and proposed solutions for repairing any identified deficiencies. This project is a Total Small Business Set-Aside under NAICS code 541330 and will be awarded as a negotiated, firm fixed-price contract. Interested firms must submit a completed SF330 by May 23, 2025, to be evaluated on professional qualifications, specialized experience, work capacity, past performance, and geographical knowledge of the project area. Only the most highly qualified firm will be eligible to receive a Request for Proposal, which is expected to be issued around July 9, 2025. All required deliverables must be completed within 349 calendar days of the award. Potential respondents must be registered in the System for Award Management to be eligible for the contract.

General Info

Agency

Department Of Defense → FA4610 30 Cons Pk

Contract Value

$1,038,908.93

NAICS

541330 - Engineering Services

Place of Performance

Lompoc, CA, 93437, USA

Set-Aside

SBA

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Notice updated

Response deadline changed from May 19, 2025 to May 23, 2025. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4610 30 Cons Pk
Contacts2 people available
OfficeVANDENBERG SFB, CA, 93437-5212, USA
Organization / Agency
Department Of Defense → FA4610 30 Cons Pk
Office AddressVANDENBERG SFB, CA, 93437-5212, USA

Full Description

Show more
Amendment 02, issued 12 May 2025, is hereby issued to incorporate the Questions received pertaining to this contract opportunity and the Government responses (Answers); refer to the attached Q&A document "243207_RFQ Q and As". Amendment 02 also hereby incorporates a revised Statement of Work dated 09 May 2025, replacing the previous version dated 14 Jan 2025; refer to document "Atch 1 243207_Revised SOW_20250509". Amendment 02 hereby incorporates the Supplimental Information document associated with this project; refer to "Atch 3 243207_Supplemental Information". Amendment 02 hereby extends the RFQ response deadline from 19 May 2025 by 3:00PM PDT to 23 May 2025 by 3:00PM PDT. All other provisions and requirements of the RFQ remain unchanged and in effect. Amendment 01, issued 24 April 2025, is hereby issued to add additional language to RFQ Evaluation Factor 4 - Past Performance regarding the PPQ template, shown underlined within Evaluation Factor 4. All other provisions and requirements of the RFQ remain unchanged and in effect. Project Number: XUMU 243207 Engineering Study, Study Launch Facilities (LF) 9 and 10 at Vandenberg Space Force Base (VSFB), CA Request for Qualifications (RFQ) for Architectural and Engineering Services Vandenberg Space Force Base, California The Architect-Engineer (A-E) shall conduct a thorough field investigation to provide a complete and usable Engineering Study that evaluates the condition of the concrete structures that make up the launch tube and surrounding area to include the identification of underground utilities supporting the launch facilities (LF 9 & LF 10) at VSFB. The Study should also capture information on groundwater levels and how water is penetrating the silos. The facility numbers associated with these two launch sites are 1993 and 1963 respectively. This Statement of Work (SOW) sets forth the requirements for a full and complete delivery method for a concrete and groundwater study at two LFs at VSFB, CA. The A-E is to provide the government with engineering documentation capturing the current state of the concrete structure and groundwater infiltration, to include a solution for repairing any deficiencies uncovered during the investigative study following all applicable codes, standards, laws, and regulations, that pertain to this project. The 30th Contracting Squadron (30 CONS) intends to issue a Request for Proposal to one (1) AE firm for project XUMU 243207, Engineering Study, Study Launch Facilities (LFs) 9 and 10 at Vandenberg SFB, on or about 09 July 2025. The award is contemplated as a Total Small Business Set-Aside. The contract will be a negotiated, firm fixed-price contract. The following North American Industry Classification System (NAICS) code applies to this RFQ: 541330, Engineering Services. The size standard for this NAICS code is $25.5M. Drawings, cost estimates, specifications, calculations, and all other deliverables required under this acquisition shall be completed within 349 calendar days after date of Award, unless otherwise agreed upon with the Government project manager and contracting officer. This acquisition will be procured pursuant to the requirements in Federal Acquisition Regulation (FAR) Part 15, Contracting by Negotiation and FAR Part 36, Construction and Architect - Engineer Contracts. All potential respondents are reminded that in accordance with FAR 52.204-7, System for Award Management (SAM), lack of registration in the SAM will make a respondent ineligible for contract award. Request for Qualifications: This Request for Qualifications (RFQ) shall not be mistaken for a Request for Proposal. In accordance with FAR Part 36.702, interested A-E firms shall submit an SF330, Architect-Engineer Qualifications, for Government evaluation by the RFQ deadline. SF330 information shall be provided per the latest format from the GSA Library located at https://www.gsa.gov/forms-library/architect-engineer-qualifications. All sections of the SF330 must be completed. All completed SF330s received by the RFQ deadline will be evaluated by the Government. Failure to provide requested data may negatively impact a respondent 's rating or determine the respondent non-responsive. In accordance with FAR Part 36.6, Architect-Engineer Services, and based on the SF330s and responses to RFQ evaluations, only the one (1) A-E firm considered to be the most highly qualified after review and discussions of the minimum requirements/evaluation factors will be eligible to receive the RFP. Evaluation Factors: In accordance with FAR Part 36.602-1, Selection Criteria, potential A-E firms will be evaluated based on the following selection criteria: (1) Professional qualifications necessary for satisfactory performance of required services. Complete this evaluation factor using Section E and Section G of the SF330. Submit personal resumes and relevant information for key and responsible personnel. Section E shall be not more than one (1) page in length per individual. Evaluation of professional qualifications will include but is not limited to an assessment of the A-E firm's individual personnel resumes. The recommended professional qualifications for satisfactory performance of the required services are defined as professional qualifications in (but not limited to): Program Manager, Project Manager, Mechanical Engineer, Civil Engineer, Electrical Engineer, Geotechnical Engineer, Structural Engineer, Geographic Information System (GIS) Analyst, Planner, Draftsman, Technical/Specifications Writer, Cost Estimator, Contract Admin/Procurement Analyst, and Clerical. Anticipated project tasks for the referenced disciplines are similar to those listed at https://www.wbdg.org/design-disciplines/planning. The professional qualifications recommended above are not the required team composition, it is a team composition that the Government considers an adequate composition for the subject requirement. Equivalent positions will be considered equally. Respondents must submit personnel resumes for all professional disciplines necessary for satisfactory performance of required services. The term - necessary denotes that the proposed team composition exemplifies that each proposed team member, through his/her personal resume, demonstrates the qualifications/competency in that discipline through experience, training, and/or certifications in their respective field. The proposed team composition must be captured in Section C and Section D of the SF330, no page limit. Note: Resumes for Draftsman, Technical/Specifications Writer, Contract Admin/Procurement Analyst, and Clerical are not required. The A-E firm shall ensure that only qualified, competent personnel carry out the tasks outlined in this SOW. Qualified, competent personnel is defined as a registered professional or, where registration is not applicable, trained, and/or certified in their respective field. Primary technical services shall be performed by individuals who are licensed in California and credentialed members of architectural, planning, science, and engineering professions or under the direct supervision of a credentialed professional in the discipline being performed. Generally, a credentialed professional (a) is licensed (e.g., registered professional engineer) to practice in the state where a facility is located and (b) commands the necessary expertise, in terms of knowledge and experience, to undertake the specified task to be identified within the contract. Failure to provide sufficient data supporting professional qualifications may negatively impact an A-E firm's rating. (2) Specialized experience and technical competence, within the past six (6) years, in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Complete this evaluation factor by providing five (5) example projects using Section F of the SF330, limited to two (2) pages per project. Both Prime and Subconsultant experience is acceptable. Respondents must identify their firm's role (prime or subcontract) for each example project. Narratives shall, when possible, be supported with illustrations or photographs of completed projects, with no more than three (3) additional pages of supporting illustrations or photographs per project. Specialized experience pertains to the types, size, volume, budget, and complexity of work previously or currently being performed by the A-E firm that is comparable to the work to be performed under this project's scope of work. Specialized experience may also include unique conditions, considerations, or circumstances encountered that are relevant to this RFQ. Specialized experience does not include overseas offices for projects outside the United States, its territories, or possessions; nor does it include subsidiaries that are not normally subject to management decisions, accounting, and policies, or a holding or parent company or an incorporated subsidiary that operates under a firm name different from the parent company. Technical competence includes construction and design projects similar in project scope, size, construction features, dollar value, and complexity of that listed in this RFQ. Similar complexity is considered projects of an operational, construction, or design likeness to the work outlined in this SOW. Specific emphasis of experience and technical competence shall be geared toward engineering studies for launch facilities, or similar. A-E firms unable to demonstrate proven specialized experience and technical competence may be considered non-responsive or scored negatively. (3) Capacity to accomplish the work in the required time. Complete this evaluation factor using Section H of the SF330. Provide a narrative that describes the A-E firm's work capacity. Narrative shall be no more than one (1) page in length. The A-E firm shall provide a brief summary of its past, present and projected future workload over the previous 12 months, through Fiscal Year 2026. The A-E firm shall describe the capacity to incorporate this project's scope of work while meeting prescribed dates for current workload. (4) Past performance, within the past six (6) years, on contracts with Government agencies and/or private industry in terms of cost control, quality of work, compliance with performance schedules, communication, satisfactory project management, and subcontract management, if applicable. Complete this evaluation factor using Section H of the SF330 describing the A-E firm's past performance on the five (5) example projects identified in Section (2) of this RFQ. The summary sheet shall be no more than two (2) pages in length per example project. Submit past performance data of example projects in narrative format that highlight cost control, quality of work, compliance with performance schedules, and satisfactory project management. Past performance data submitted as a subconsultant must be identified as such on the PPQ and must be completed by the Prime contractor. The narratives of example projects must show contract number, issuing agency, project name, a current point of contact (including telephone and email information); project scope, size, and location; design fees, total number of modifications or change orders issued during performance of project; date of project completion, construction cost estimate, principal design elements and features; complexity of the job, challenges faced and actions taken; and the resolution and results of any challenges faced. If known, list the construction contract award price, and the total number of construction contract modifications/change orders and their total value. CPARS data or Past Performance Questionnaires (PPQ) must be provided for all example projects submitted under this Section. Respondents without a record of relevant past performance or for whom information on past performance is unavailable will not be evaluated favorably or unfavorably on past performance, however, respondents who provide past performance data may be evaluated higher for this factor. If relevant CPARS evaluation(s) are available, report(s) shall be submitted with the completed SF330 package. CPARS reports and PPQs are not considered part of the page limitations for this Section. If there is not a completed CPARS evaluation, the PPQ included with this notice is provided for the respondent or its team members to submit for each project included in criterion (2). Official CPARS evaluation(s) found in in government databases will take precedence. Completed PPQs should be submitted with your SF330. Note: The provided PPQ template is not a required template for use; the Respondent may submit an alternative PPQ template as part of the response to Evaluation Factor 4 - Past Performance so long as the submitted PPQ addresses all the information required in Section 1 of the provided PPQ template (Attachment 2) and, at a minimum, provides an evaluation of all six (6) performance factors plus the Summary questions in Section 2 of the provided PPQ template. The adjectival ratings and definitions used to reflect the evaluation of performance must match those on the provided PPQ template. Respondents are notified that the Government may use sources of information such as, but not limited to the Contractor Performance Assessment Reporting System (CPARS) to determine a respondent's relevant experience and past performance as part of this evaluation. The evaluation of past performance will include but is not limited to: The customer's assessment of the respondent 's quality of work; record of conforming to contract requirements and applicable codes, standards, laws, and regulations; history of satisfactory project management and collaboration with the customer; addressing design errors/omissions timely; and adherence to approved schedules. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, and Contracting Officer knowledge of current project performance. Failure to demonstrate proven competence to perform design services similar in scope and complexity to this acquisition may be considered ineligible for award. (5) Location in the general geographical area of the project and knowledge of the locality of the project. Complete this evaluation factor using Section H of the SF330. Provide a narrative that describes the respondent's experience with developing engineering studies for launch facilities, or similar, located in California. Narrative shall be no more than one (1) page in length. Respondents will be objectively evaluated based on their knowledge and familiarity (and the knowledge of subcontractors) with applicable codes, standards, laws, and regulations, that pertain to this project. If prior experience in California is minimal or unavailable, describe how the design team plans to obtain specific knowledge of local conditions or project features required for a compliant design. Data from other projects and locations are acceptable to highlight knowledge of applicable codes, standards, laws, and regulations, that pertain to this project. Higher ratings may be given for prior experience working on Vandenberg Space Force Base. Evaluation Factors Page Limitations: Factor 1: Professional Qualifications SF330 Section: E, G Page Limit: E: 1 page per individual, no maximum page limit, G: no limit Factor 2: Specialized Experience SF330 Section: F Page Limit: 2 pages per project, plus 3 pages of supplementary illustrations and photographs per project Factor 3: Capacity SF330 Section: H Page Limit: 1 page Factor 4: Past Performance SF330 Section: H Page Limit: 2 pages per project (no page limit on CPARS or PPQs) Factor 5: Location SF330 Section: H Page Limit: 1 page *Note: There is no cumulative page limit Notice to potential respondent(s): Funds are not presently available for this effort. No award will be made for this effort until funds are available. The Government reserves the right to cancel this acquisition, either before or after the deadline for receipt of SF330s. In the event the Government cancels this acquisition, the Government has no obligation to reimburse a respondent of any cost. Questions and Answers: Questions regarding this post are due no later than 28 April 2025 by 3:00PM PDT, responses to all questions received will be added to the SAM.gov post on or about 05 May 2025. Only questions related to the RFQ and project requirements will be addressed; questions regarding details of the resulting RFP will not be answered. RFQ Response Due Date: Responses to this RFQ are due no later than 23 May 2025 by 3:00PM PDT. Late responses will not be considered for further elevation. NOTE: It is the responsibility of all potential respondents to monitor these sites for release of any future notices and/or release of amendments. General inquiries regarding this notice may be emailed to the Contracting Officer, Meghann Applebay at meghann.applebay@spaceforce.mil and the Contract Specialist, David Coatney at david.coatney@spaceforce.mil. Please note that due to increased firewall protections, some emails may be blocked; therefore, a follow-up via telephone at 805-605-2465 (if an acknowledgement is not received via email) is strongly recommended to ensure receipt of your submission by the Government.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS