Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Department Of Defense was posted on May 14, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

RESPIROMETER

Closed
SPE2DS-26-T-075CFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract pertains to the supply of a Digital Respirometer Model 295, a medical device designed to measure tidal volume air or gas flow with a capacity of up to 200 liters. The respirometer features an LCD display and a flow sensor unit that contains only one moving part, which can be detached for easy sterilization through washing, gas sterilization, or cold sterilization. It comes ready to use with a 9V battery and includes a 22mm female-to-female adapter. The device offers a measurement resolution of 0.02 liters, a flow rate range from 5 to 150 liters per minute, with an accuracy of 5% across its full range and 2% at the calibration point, while maintaining a flow resistance of 2 cm of water at 100 liters per minute. Packaging and shipping are required to adhere to commercial standards suitable for protecting the unit during transport, including compliance with Medical Marking Standard No. 1 to ensure proper labeling and handling. This solicitation, identified by number SPE2DS-26-T-075C, calls for one unit of the respirometer, with delivery expected within 20 days after award, and is managed by the Medical Supply Chain MD SURG FSF under the Department of Defense. The item is to be shipped to Joint Base Charleston, South Carolina, and bidders are requested to specify source and part number when submitting proposals. The contract references specific technical and quality requirements as outlined in the DLA master list, and adherence to packaging instructions is mandatory to ensure acceptance and safe delivery at the lowest carrier rates. This procurement is governed by relevant contract clauses, including the removal of government identification from non-accepted supplies, and is intended for government medical acquisition use.

General Info

Supply of one Digital Respirometer Model 295, accuracy 5%, delivery in 20 days, DoD contract.

Agency

Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF

NAICS

339112 - Surgical and Medical Instrument Manufacturing View NAICS

Place of Performance

204 S GRAVES AVE, JOINT BASE CHARLESTON, SC, 29404, US

Set-Aside

NONE

Documents

(1)

SPE2DS-26-T-075C.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
ContactsNo contacts available
OfficeUS
Organization / Agency
Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Office AddressUS
ContactsNo contact information available

Full Description

Show more
RESPIROMETER
RESPIROMETER.
Respirometer Digital Complete w/ Sensor Controller Adapter to 200 liters. With LCD readout display on the Model. 295 Digital Respirometer. The flow sensing unit has only one moving part and is detachable from the control unit for ease of sterilization and cleaning. It may be washed, gas sterilized or cold sterilized. Comes complete as shown, ready to use with 9V battery and one (1) 22mm female x 22mm female adapter. Range: 0 200 liters. Measurement Type: Air/Gas volume flow (tidal volume). Resolutions: .02 liter. Flow Rate: 5 lpm minimum/150 lpm maximum. Accuracy: 5% over range, 2% at calibration point. Resistance to flow: 2cm of water at 100 lpm.
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED IN A SUITABLE SEALED UNIT CONTAINER CAPABLE OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT THE LOWEST RATE, TO POINT OF DELIVERY CALLED FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1 (MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
UNIT OF ISSUE: EACH (EA)
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
SPE2DS-26-T-075C
SECTION B
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-696-5384 Quantity: 1 EA Purchase Request: 7016781143QTY: 1 Delivery: 20 days ADO