Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from New York was posted on March 9, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

RetrofitNY Component Manufacturer Qualification

Closed
RFQL 4551State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

NYSERDA is seeking to qualify Component Manufacturers to provide high-performance envelope treatments, integrated mechanical systems, and monitoring systems for multifamily low- and mid-rise buildings in New York State. The goal is to identify suppliers capable of delivering solutions that approach or achieve carbon neutrality. Qualified manufacturers will be eligible to work with approved Solution Providers on pilot projects, which may subsequently receive gap-funding from NYSERDA. It is important to note that this specific qualification process does not provide direct funding to the manufacturers. To be eligible, manufacturers must provide components applicable to specific multifamily building typologies and comply with all New York State fire, building, and housing codes. Requirements include a willingness to collaborate directly with Solution Providers, participate in RetrofitNY showcases, and provide financial stability verification from a company officer. Qualified participants must also agree to share non-proprietary data to improve unit economics and allow their company information and component descriptions to be posted on a secure NYSERDA site. The deadline for responses is December 31, 2025.

General Info

NYSERDA seeks qualified component manufacturers for carbon neutral multifamily building pilot projects.

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNew York → Nyserda
Contacts4 people available
OfficeN/A
Organization / AgencyNew York → Nyserda
Office AddressN/A
Contacts
Senior Project Manager1359 Broadway, 19th Floor
Saul BrownProject Manager
Elsyda SheldonAssistant Contract Manager
Jillina BaxterOffice Manager

Full Description

Show more
Description of goods to services to be bid: The following changes have been made to the RFQL 4551 Participation Agreement: RFQL Summary1. Updated program contact2. Updated to Governor Hochul3. Updated definitions throughout the document to be consistent with PON 4878 4. Clarified existing languages5. Updated RetrofitNY Pledge count6. Corrections made to typos7. Removed program policy factors per legal advice8. Reframed NZE with Carbon Neutral or Carbon Neutrality9. Revised Eligibility Requirements and Evaluation Criteria for the Mechanical System to allow for individual mechanical component in addition to unitized solution and add energy recovery ventilation (ERV) as an additional qualifying component10. Removed webinar registration info table and add language to request recordings Attachment A - Component Manufacturer Application1. Added a new term allowing the applicant to submit families of products as a single component2. Reframed NZE with Carbon Neutral or Carbon Neutrality 3. Updated definitions throughout4. Required signature (Section E – Application Certification) for each component5. Labeled optional/required on each exhibit Attachment B – Unit Economics Worksheet1. Updated definitions throughout Attachment C - Innovation Areas Self Assessment1. Reframed NZE with Carbon Neutral or Carbon Neutrality2. Updated definitions throughout Attachment D – Performance Specs1. Reframed NZE with Carbon Neutral or Carbon Neutrality Attachment F – Embodied Carbon Calculators and Resources1. Reframed NZE with Carbon Neutral or Carbon Neutrality Attachment G – Component Information Sheet1. Moved contact information to the top and clarify existing language 2. Reframed NZE with Carbon Neutral or Carbon Neutrality3. Updated definitions throughout Attachment H - Participation Agreement Letter1. Rephrased languages to remove NYSERDA’s countersignature 2. Added Term 23: public posting of company name, contact information, portfolio size and location, and participation rationale on RetrofitNY website3. Updated definitions throughout 4. Reframed NZE with Carbon Neutral or Carbon Neutrality5. Correction made to Appendix D on the initial price point of the Envelope System Through this Request for Qualifications (RFQL), NYSERDA will qualify Component Manufacturers to supply key components for a high performance retrofit solution that approaches or achieves net-zero energy performance. These components include, at minimum, whole-building high-performance envelope treatments, integrated mechanical systems, and monitoring systems. Components must be applicable to multifamily low- and mid-rise buildings in New York State. Component Manufacturers qualified through this RFQL will be eligible to supply components to Solution Providers qualifed through a separate RFQL to furnish and install a high performance retrofit solution on pilot Buildings qualified through a third RFQL. These pilot projects will then be eligible to receive gap-funding from NYSERDA through a forthcoming solicitation to defray the cost of the retrofit solution. No NYSERDA funding is associated with this RFQL whose sole purpose is to qualify Component Manufacturers for the next round of RetrofitNY pilot projects. If changes are made to this solicitation notification will be posted on NYSERDA’s website at: www.nyserda.ny.gov/funding-opportunities Eligibility/Qualifications Requirements/Preferences: The minimum eligibility requirements for Component Manufacturers are as follows: 1. The component must be applicable to one or more of the eight multifamily building typologies described in Section III.E.2 Prevalent Building Types of RFQL 4551 and relevant to a NZE Whole Building Retrofit Solution.2. The Component Manufacturers are expected to collaborate with at least one Solution Provider delivering scalable, NZE Whole Building Retrofit Solutions and must, at a minimum, express a willingness to enter into agreements with one or more Solution Providers directly (and not through intermediaries).3. Components will be qualified that fully satisfy all the functional needs of one or more of the following categories:a) Mechanical Systems: offsite manufactured mechanical system that delivers efficient electrified space heating, cooling, heat recapture ventilation and humidity control, and domestic hot water (DHW) generation. b) Envelope Systems: off-site manufactured panelized systems designed for Whole Building Retrofit Solutions in one or more of the building types identified in Section III.E.2 Prevalent Building Types of RFQL 4551. c) Monitoring Systems: measure and display relevant building performance information to various stakeholders (building owners, residents, service contract providers, building management). 4. The component must meet all New York State fire and building code requirements and satisfy NYS Housing and Community Design Guidelines and NYC Housing Preservation & Development Specifications for Rehabilitation Projects.5. The Component Manufacturer must be willing to participate in showcases held by RetrofitNY designed to familiarize building owners with Whole Building Retrofit Solutions.6. If qualified, the Component Manufacturer must share with RetrofitNY, within 60 days of qualification and on an annual basis, information about opportunities, absent proprietary details, to significantly improve the unit economics on the Whole Building Retrofit Solution and its major components. 7. If qualified, the Component Manufacturer must provide RetrofitNY, within 30 days of qualification, with a short description of its components approved through this RFQL and agree to allow RetrofitNY to post the descriptions of the solutions to a secure NYSERDA site for qualified Solution Providers and qualified Building Owners to review. 8. If qualified, the Component Manufacturer must provide, within 30 days being qualified under this RFQL, a letter from the company’s CFO or officer with fiduciary responsibility that includes two references and attests to the fact that the company it is financially stable and has sufficient cash on hand to deliver the specified component. 9. If qualified, the Component Manufacturer must regularly review, with the relevant Solution Provider, the deployment of Whole Building Retrofit Solutions in order to discuss errors, suggest changes in design or process, allow for the accumulation of knowledge from one project to the next, find efficiencies, improve the onsite installation process and improve quality control.10. The Component Manufacturer must complete and submit the Component Manufacturer Workbook and must, within 30 days of a request, furnish any additional documentation, within reason, requested to support the information submitted in the workbook. 11. If qualified, the Component Manufacturer must execute the Component Manufacturer Participation Agreement which allows RetrofitNY to determine if the qualified Component Manufacturer continues to meet the minimum criteria listed in the RFQL 4551. Service-Disabled Veteran-Owned Set Aside: No Due date:12/31/2025 3:00 PM Contract term: N/A County(ies): All NYS counties Location: New York State

More opportunities from New York → Nyserda

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS