This Solicitation opportunity from Michigan was posted on August 20, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
RFP-171-260000002447-3 | 511/26450.JLM; Battle Creek ANG-A31 ADAL Server Rm 6900
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This solicitation is for professional architectural and engineering services tied to the Battle Creek Air National Guard Base in Michigan, specifically the A31 ADAL Server Room 6900 project in Building 6900. Issued by the Michigan Department of Technology, Management and Budget on behalf of the Michigan Department of Military and Veterans Affairs and the Michigan Air National Guard, it seeks a contractor to renovate and right-size an existing 310-square-foot server room so it can securely house the base’s SIPR head-end and support classified network requirements. The work is intended to be UFC-compliant and aligned with ANG design procedures, with emphasis on resilient, secure infrastructure and coordination with Air National Guard-specific standards. The procurement is an RFP for a not-to-exceed, billable-rate professional services contract, and while no contract value is stated, the offeror must propose pricing for the requested design services. The scope covers schematic, preliminary, and final design phases, with detailed requirements spanning architectural, electrical, mechanical, fire protection, and cybersecurity-related facility controls. The design must accommodate current IT loads plus 25% growth, include reinforced flooring and TEMPEST-compliant partitioning, provide redundant dual A/B electrical distribution with automatic generator cutover, and ensure generator-backed support for lighting, IDS, access control, wall outlets, and fire suppression systems. Mechanical systems must use N+1 precision cooling with hot aisle/cold aisle containment, and fire protection must include an NFPA 2001 clean agent system, very early warning smoke detection, room sealing, and emergency power-off controls. The project also requires integration of cybersecurity considerations, including C-I-A ratings and tailored security controls for facility-related systems. Applicable standards include ANGETL 24-02, UFC 3-600-01, UFC 4-141-03 Grade 3 concepts for critical system redundancy, and MIL-STD-3007G re-evaluation if design-to-solicitation timing exceeds 18 months. The solicitation requires a technical proposal and a cost proposal, with evaluation based on technical merit and cost, and the contractor must identify a project manager and supporting key personnel who are assigned to the account, knowledgeable about contract requirements, and responsive within 24 hours. Proposals must be submitted electronically through SIGMA VSS by 2:00 p.m. Eastern on August 27, 2026, with no facsimile or email submissions accepted and attachments limited to 25 MB each. A mandatory pre-proposal meeting and site visit were scheduled, and an addendum clarified
General Info
Agency
Place of Performance
MI, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
More opportunities from Michigan → DTMB
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
