This combined synopsis and solicitation seeks a collaborative robotic arm and associated equipment to support regulatory science research for the Interventional, Radiological Imaging and Visualization program. The procurement aims to develop measurement methodologies for evaluating head mounted displays and image registration in interventional procedures, ensuring alignment with FDA and IEC standards. The required system must include a 6-axis robotic arm with a 5-10kg payload and 750-950mm reach, a dedicated controller with specific I/O ports, a teach pendant with a touch screen of at least 8 inches, and a permanent software license compatible with Windows or Linux that supports third-party integration via SDKs or APIs. The successful contractor must deliver all items in new, usable condition to the FDA CDRH facility in Silver Spring, Maryland, within 60 days of the award. The period of performance is 12 consecutive months starting from the award date. Quotes are due by September 11, 2025, at 4:00 P.M. EST and should be submitted via email to the designated point of contact.
General Info
Agency
NAICS
Place of Performance
Silver Spring, MD, USASet-Aside
Documents
(2)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued.
Background:
The procurement is to support regulatory science tools development for the Interventional, Radiological Imaging and Visualization regulatory science research program. Developing measurement methodologies for technical performance is critical for consistent evaluation of head mounted displays and image registration in interventional procedures. Specifically, the procurement for a robotic arm to precisely control the position and orientation of surgical tools to quantitatively characterize the spatial and temporal stability and accuracy of image registration. In addition, the robotic arm will also allow for controlled movement of an augmented and virtual reality head mounted displays (HMDs) or camera system to evaluate registration performance visualized through the HMD including simulated user movement.
These types of technologies are increasingly being incorporated in medical devices across OPEQ. The range of motion of the robotic arm will allow for developing image registration regulatory science tools for a wider range of device types with more complex motions than are achievable with a linear translation stage. Finally, the robot will allow for greater flexibility in targets and cameras for characterizing registration using HMDs. This will align the Office of Science and Engineering Laboratories (OSEL) instrumentation with FDA recognized standards, such as the Instrumental Commission (IEC), for head mounted displays, which is essential for the OSEL mission of developing regulatory science tools. The collaborative robotic arm will be incorporated into an existing bench setup using custom developed software for controlling a collaborative robotic arm.
Minimum Performance Requirements:
Item 1:
Collaborative Robotic Arm
• Degrees of Freedom: 6 rotating joints
• Payload: 5-10kg
• Reach: 750-950 mm
• Tool Movement at Tool Center Point (TCP)
TCP location: Should support both TCP locations
100-200mm from center of face-plate on tool z-axis (along rotation axis of joint 6)
100-200mm from center of face-plate on the tool x-axis (orthogonal to rotation axis of joint 6).
Range of TCP movement (position and orientation):
X: at least 150mm
Y: at least 150mm
Z: at least 150mm
Yaw angle: at least +/- 45o
Pitch angle: at least +/- 45o
Roll angle: at least +/- 20o
• Maximum speed per joint: at least 180o/s
• Maximum TCP velocity: at least 0.5 m/s
• Joint movable range: Minimum rotation angle of each joint of all six joints must be more than 220o.
• Position detection: encoders
• Brakes mechanism that locks and unlock joint, including in an emergency and by user request.
• Repeatability: less than 0.035 MM
• Weight: less than 30kg
• Protection and Sealing of the robot: Protection from tools and small wires, such as IP40 or higher.
• Mounting: Standard required. Optional for side or inverted mounting.
• Cable length: at least 2 m
• Footprint Size: less than 175 mm x 175 mm
Item 2:
Controller
• Power: 120V 50-60Hz AC preferred, 220V acceptable.
• Maximum Controller size (W x H x D): 500 mm x 500 mm x 500 mm
• I/O ports:
Digital input ports: min 8 ports
Digital output ports: min 8 ports
Analog input ports: min 2 ports
• USB ports: min 2 ports (2.0 or 3.0)
• Ethernet port: min 1 port
• Display port for external screen: min 1 port.
Item 3:
A control box for programming the motions of a robot. Also called teach box or teach pendant.
• Manually move and reorient the robotic arm
• Ability to program using GUI through the teach pendant.
• Touch screen of a size 8 in or larger
• Emergency stop switch/button.
• Connectivity: Wireless or by a cable length of at least 2 m
• Weight: less than 3.5 kg
Item 4:
Software
• Tool Center Point (TCP) calibration procedure
• Permanent software license
• Support for controlling the robotic arm and camera systems with third party software, such as LabVIEW, MATLAB, Visual Basic, C++, C#, or Python. Support may include a software development kit (SDK) with all required application programing interface (API) and libraries for software development, drivers, or ActiveX support.
• Compatible with Windows 10, Windows 11, or Linux Operating System
Deliverables: The Contractor shall deliver the item and quantities ordered within 60 days of award.
All deliverables required under this contract shall be packaged, marked, and shipped in accordance with Government specifications. At a minimum, all deliverables shall be marked with the contract number and contractor’s name. The Contractor shall guarantee that all required materials shall be delivered in immediate new, usable, and acceptable condition.
Place of Supply Delivery and Place of Performance:
The equipment should be complete with all accessories and software necessary to work and to be delivered to:
US FDA CDRH DIDSR
Attention: Beams, Ryan
10903 New Hampshire Avenue
WO62 RM 3126
Silver Spring, Maryland 20993
PH: 240-402-3216
Fax: 301-796-9925
Email: Ryan.Beams@fda.hhs.gov
Period of Performance:
12 consecutive months commencing upon date of Award.
Please see the attached Statement of Work and corresponding ancillary documents for review and consideration.
Quotes are due by email on or before September 11, 2025, by 4:00 P.M. (Eastern Standard Time) and should be sent to brandon.rafus@fda.hhs.gov.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Health And Human Services → FDA Office Of Acq Grant Svcs
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS