Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

San Ysidro High School Gym Roof and HVAC Replacement Project

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Sweetwater Union High School District is initiating the San Ysidro High School Gym Roof and HVAC Replacement Project at 5353 Airway Road, San Diego, California. The project focuses on replacing an aging gymnasium roof and an inadequate HVAC system with a new single-ply roof assembly that meets Title 24 requirements and replacing standing-seam metal roof sections in high-roof areas. The scope of work includes replacing deteriorated flashing, curbs, and drainage elements, as well as installing new primary and overflow drains to correct existing deficiencies. To support the new rooftop HVAC units, the project involves verifying and reinforcing structural framing and anchorage, installing new mechanical equipment, curbs, pads, and associated ductwork, and implementing new electrical circuits, conduits, and controls. Additional improvements include the installation of hose bibbs for roof cleaning and the implementation of OSHA-compliant roof access provisions, such as a new roof access hatch, guardrail system, exterior ladder improvements, roof walk pads, and fall-protection tie-off posts. The project is designed to bring recreational amenities up to current State and District standards and ensure compliance with the Americans with Disabilities Act. This maintenance and upgrade effort will not expand the gymnasium's capacity, student enrollment, building footprint, or operational hours, and it qualifies for categorical exemptions under CEQA Sections 15301, 15302, and 15303. The project is managed by the Director of Planning and Construction, Jason Brust, and is authorized under Resolution No. 5032.

General Info

Renovate San Ysidro High School gym roof and HVAC system, comply with Title 24 and OSHA standards, no footprint expansion.

Agency

California → Sweetwater Union High School District

Place of Performance

Airway Road and Caliente Avenue, San Diego, CA, 92154

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Sweetwater Union High School District
Contacts1 person available
OfficeN/A
Organization / Agency
California → Sweetwater Union High School District
Office AddressN/A
Contacts
Jason BrustDirector, Planning and Construction

Full Description

Show more
San Ysidro High School is currently operating with an aging gymnasium roof and an inadequate HVAC system. To address this, the District is proposing to replace the existing gymnasium roof and install a new rooftop HVAC system at San Ysidro High School, located at 5353 Airway Road, San Diego, CA 92154. The project would include replacing the existing roof systems with a new single-ply roof assembly that meets current Title 24 requirements; replacing deteriorated flashing, curbs, and drainage elements; verifying and reinforcing structural framing as necessary to support new rooftop HVAC units; installing new mechanical equipment, curbs, pads, and associated ductwork; installing new primary roof drains and overflow drains to correct existing drainage deficiencies; installing new electrical circuits, conduits, and controls for the new mechanical units; and installing a new roof access hatch, guardrail system, exterior ladder improvements, roof walk pads, and fall-protection tie-off posts to meet Occupational Safety and Health Administration-compliant roof access provisions. No expansion of the gymnasium's capacity, student enrollment, building footprint, or operational hours would occur. All construction activities would be confined to the existing gymnasium rooftop, and the proposed project would not alter the function or use of the gymnasium.

Similar Contracts

Same NAICS industry code

NAICS: 238160
New
Inland Empire Job Corps-Request for Quote Roof Design & Build
Solicitation # inland-empire-job-corps-request-quote-roof-design-build
Management & Training Corporation is seeking quotes for a fixed-price design-build subcontract to construct an over-build enclosure for the lower roof of Building G at the Inland Empire Job Corps Center in San Bernardino, California. The project involves designing and installing a roof covering approximately 800 gross square feet, featuring a 3% sloped roof with a single ply, EPDM 60 mil roofing system over wood or metal decking. The scope includes structural framing that extends existing bearing walls or utilizes a new post-beam system, the installation of three LED strip light fixtures with one emergency backup, and strict adherence to OSHA safety standards and the Architectural Barriers Act Accessibility Standard of 2007. The total period of performance is 240 days, with a requirement to complete the work within 100 consecutive business days following the Notice to Proceed. Bids are due by November 2, 2026, and will be evaluated based on overall best value. This is a small business set-aside opportunity open to various SBA certifications. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety with at least an A- rating. Bidders must conduct a physical site visit and sign an attendance roster to be eligible. The project is subject to Construction Wage Rate Requirements, necessitating compliance with California prevailing wages and the submission of weekly certified payroll reports. Additionally, all inspections and testing must be conducted by an independent, third-party agency registered in California. Required insurance minimums include 1 million dollars per occurrence for general liability, 1 million dollars for auto, and 500,000 dollars for workers compensation.
Inland Empire Job Corps

POSTED

about 3 hours ago

DEADLINE

in 10 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS