SENSOR, OXYGEN ANALY
Active
SPE2DS-26-T-356AFederalResponse Deadline
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSFView Agency
NAICS
334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical SignalsView NAICS
Place of Performance
USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
PhaseSolicitation
Response Deadline
Organization & Contact Information
Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Contacts1 person available
OfficeUSA
Office AddressUSA
Contacts
Full Description
Show more
SENSOR,OXYGEN ANALY
SENSOR,OXYGEN ANALY GENERAL PURPOSE SELF-CONTAINED OXYGEN SENSOR:
PERCENT OXYGEN IN NON-FLAMABLE SAMPLES; EXTREMELY STABLE, LONG-LIFE
SENSOR; STANDARD 0-2.5VDC OUTPUT: ISOLATED 4-20MA OUTPUT OPTIONAL.
OPERATING TEMPERATURE: 0 DEG F TO 130 DEG F. POWER REQUIREMENTS: BETWEEN
7 AND 28 VDC (NOMINALLY 24VDC) TYPICALLY 250 MA AT 12VWITH NO EXTERNAL
DRAW FROM THE 5V SUPPLY. CURRENT DRAW IS HIGHER AT LOWER VOLTAGE AND
LOWER AT HIGHER VOLTAGE.
. UNIT OF ISSUE EACH (EA).
NOTE TO BUYER
CUSTOMER WILL NEED TO BE CONTACTED IN ORDER TO SELECT
OPTIONS.
This model needs some options to be selected in order to provide a complete quote.
Please advise on the following required options:
1. Measurement Range: 0-25%, 0-50%, or 0-95%?
2. Analog output: 0-2.5VDC or 4-20mA?
3. Diffusion screen, compression fittings, or barbed fittings?
Price on probes are either $742.00 or $982.00
CONTACT INFO AMI INSIDE SALES Derek Johnsondjohnson@amio2.com(714) 848-5533
. RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
ADEQUATE DATA FOR THE NSN/Part Number: 6630-01-680-1727 Quantity: 1 EA Purchase Request: 7017937325QTY: 1 Delivery: 20 days ADO
SENSOR,OXYGEN ANALY GENERAL PURPOSE SELF-CONTAINED OXYGEN SENSOR:
PERCENT OXYGEN IN NON-FLAMABLE SAMPLES; EXTREMELY STABLE, LONG-LIFE
SENSOR; STANDARD 0-2.5VDC OUTPUT: ISOLATED 4-20MA OUTPUT OPTIONAL.
OPERATING TEMPERATURE: 0 DEG F TO 130 DEG F. POWER REQUIREMENTS: BETWEEN
7 AND 28 VDC (NOMINALLY 24VDC) TYPICALLY 250 MA AT 12VWITH NO EXTERNAL
DRAW FROM THE 5V SUPPLY. CURRENT DRAW IS HIGHER AT LOWER VOLTAGE AND
LOWER AT HIGHER VOLTAGE.
. UNIT OF ISSUE EACH (EA).
NOTE TO BUYER
CUSTOMER WILL NEED TO BE CONTACTED IN ORDER TO SELECT
OPTIONS.
This model needs some options to be selected in order to provide a complete quote.
Please advise on the following required options:
1. Measurement Range: 0-25%, 0-50%, or 0-95%?
2. Analog output: 0-2.5VDC or 4-20mA?
3. Diffusion screen, compression fittings, or barbed fittings?
Price on probes are either $742.00 or $982.00
CONTACT INFO AMI INSIDE SALES Derek Johnsondjohnson@amio2.com(714) 848-5533
. RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
ADEQUATE DATA FOR THE NSN/Part Number: 6630-01-680-1727 Quantity: 1 EA Purchase Request: 7017937325QTY: 1 Delivery: 20 days ADO
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Same awarding agency
