Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Justice was posted on January 22, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

SEWAGE LIFT STATION

Closed
15B11121QW0000006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 221320
New
Sioux City Wastewater Treatment Plant Facility Plan - Phase 1 Improvements Project
Solicitation # sioux-city-wastewater-treatment-plant-facility-plan-phase-1-improvements-project
The Sioux City Wastewater Treatment Plant Facility Plan Phase 1 Improvements Project, managed by Rice Lake Construction Group, involves extensive infrastructure upgrades and modernization of wastewater treatment facilities in Iowa. Key mechanical and process improvements include the replacement of preliminary treatment equipment, primary clarifiers, and the RAS pump station, alongside the rehabilitation of aeration tanks and the conversion of an anaerobic digester for sludge storage. The project also encompasses the construction of a new secondary control building, the installation of plant-wide odor control systems, and critical electrical upgrades including new main switchgear and standby emergency power generators. The scope of work requires comprehensive demolition of unused structures and buildings, as well as significant site and civil improvements to meet NFPA 820 and other safety standards. Requested materials and services span a wide range of disciplines, including hazardous material abatement, concrete and masonry work, HVAC, plumbing, and the installation of specialized process gas and liquid handling equipment. This large-scale solicitation seeks contractors capable of delivering integrated electrical, instrumentation, and water treatment solutions to enhance the overall efficiency and safety of the plant.
Rice Lake Construction Group

POSTED

about 9 hours ago

DEADLINE

in 7 days
NAICS: 221320
New
Federal
Y--GRCA 257282 - Replace Wastewater Plant at South Ri
Solicitation # 140P2026R0101
Solicitation 140P2026R0101 is an unrestricted full and open competition Invitation for Bid issued by the National Park Service, DSC Contracting Services Division, for the replacement of the South Rim Wastewater Treatment Plant at Grand Canyon National Park, Arizona. The project involves the construction of a GD Membrane Bio-Reactor wastewater treatment plant, including new treatment facilities, administrative and support buildings, and process systems. The scope of work encompasses complete demolition and removal of existing infrastructure, site preparation, grading, paving, fencing, and improvements to the facility access road. The project is estimated to exceed 100 million dollars, with a period of performance from February 1, 2027, to February 1, 2030, and a revised assumed Notice to Proceed date of April 1, 2027. The government will utilize a multi-factor, best-value tradeoff process for award, evaluating technical experience, technical approach, key personnel experience, and price. Key requirements include the provision of performance and payment bonds, adherence to union prevailing wage rates, and a 12-month operational support period following construction. Technical specifications emphasize strict cybersecurity hygiene for SCADA/MES equipment, full government rights to supplied software and source code, and compliance with ADA standards. Proposals must be submitted electronically in separate volumes, with specific evaluations focusing on the contractor's ability to manage complex wastewater plant commissioning and regulatory approvals.
Dsc Contracting Services Division

POSTED

5 days ago

DEADLINE

in 29 days
NAICS: 221320
Federal
Waste Water Treatment Plant Services
Solicitation # FA448627Q0002
Solicitation FA448627Q0002 is a Request for Quotation issued by the Department of the Air Force for Waste Water Treatment Plant Services at Lajes Field in Praia da Vitoria, Azores, Portugal. The contractor will be responsible for the operation and maintenance of a waste water treatment plant with a capacity of 800,000 gallons per day, as well as the associated lift station, oil-water separator, and grease traps. Key requirements include providing a Lead Operator with a Level II or higher WPI Certification and at least three years of experience, implementing a 52-week preventive maintenance plan, and ensuring compliance with ISO/IEC 17025 laboratory standards and Portuguese decree law 183/2009 for waste landfills. The scope also encompasses corrosion control, painting, and the management of hazardous materials. The government intends to award a single Firm-Fixed-Price contract with a total duration not to exceed 66 months, consisting of a base period and four option periods. This is an unrestricted acquisition, and proposals must be submitted electronically by November 23, 2026, at 14:00 Azores Time. Offers are evaluated through a three-step sequential process: an administrative compliance review, a technical acceptability evaluation based on experience, approach, and a quality control plan, and finally a price evaluation in Euro currency. Award is contingent upon the availability of funds. Payments will be processed electronically via the Wide Area WorkFlow system.
FA4486 765 Abs Conf

POSTED

9 days ago

DEADLINE

in about 1 month
NAICS: 221320
Federal
DCDO Septic Tank and Sewage Treatment Maintenance
Solicitation # FA527027QB006
The United States Air Force 18th Contracting Squadron is soliciting quotations for a single-award, firm-fixed-price requirements contract to provide septic tank and sewage treatment plant maintenance services for the Defense Communications Detachment Okinawa (DCDO) in Okinawa, Japan. The contract encompasses a base period from December 1, 2026, to November 30, 2027, with four subsequent option periods extending the total performance through November 30, 2031. The scope of work includes implementing a Preventive Maintenance Inspection Service program, performing general maintenance and repairs, and responding to routine service calls within 24 hours. All maintenance personnel must be certified plant operators approved by the Government of Japan Ministry of Public Health and Welfare. Award will be granted to the responsible offeror whose proposal is determined to be the most advantageous to the government, with price serving as the primary evaluation factor. To be considered responsible, quoters must submit current Industrial Waste Disposal or Collection and Transportation Business licenses. Deliverables include quarterly work reports and personnel access lists submitted one week prior to starting work. The contractor must also adhere to strict marking and labeling standards for any delivered items per MIL-STD-130 and MIL-STD-129. Quotations must be submitted electronically by October 26, 2026, and must include a detailed pricing breakdown via the provided Price Exhibit.
FA5270 18 Cons Pk

POSTED

13 days ago

DEADLINE

in 5 days

General Info

Contract Value

$202,604

NAICS

221320 - Sewage Treatment Facilities

Place of Performance

Memphis, TN, 38134, USA

Set-Aside

SBA

Award Issued Date

Documents

4

DOL+Wage+Rates.txt

TXT

RFQ.pdf

PDF

SF-30+Amendment+Solciitation.pdf

PDF

SOW+%28Lift+Station%29.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Deadline changed

Response deadline changed from Jan 22, 2021 to Jan 29, 2021.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Justice → Fci Memphis
Contacts2 people available
OfficeMEMPHIS, TN, 38134, USA
Office AddressMEMPHIS, TN, 38134, USA

Full Description

Show more
STATEMENT OF WORK UPGRADE SEWAGE LIFT STATION FCI MEMPHIS- 1D1T 1. GENERAL: A.INTRODUCTION The Federal Bureau of Prisons (FBOP), Federal Correction Institution, Memphis, TN is soliciting a contractor to make a single award to a responsible entity that will provide repairs and upgrades to a undersized and failing sewage lift station. These upgrades will include replacing the existing grinder with a larger grinder, replacing the current pumps with new pumps, replacing existing pump floats, and replacing all electronic controls and housings. SCOPE OF WORK The contractor would be required to remove the existing Lift stations grinder, motors, floats, and electronic motors controls completely and replace them with a new larger grinder, grinder, motors, floats, and electronic motors controls. Updated equipment shall meet the technical guidelines specifications in the section titled "Equipment''. The contractor will provide all skilled labor, tools, equipment and materials to remove and install all Lift Station components. EQUIPMENT 30005-0018-DI Grinder 7T Cam Cutters 1:1 Stack Hardened Alloy STL Buna N Elastomers Cork & Rubber Gaskets Delta P Side Rails Motor Type: Hydraulic New Torque Motor New Spool Paint Epoxy Green NEW Grinder SN: TBD Part Number: PC2240 PC2240 Motor Controller SHP Hydraulic Motor 208V/3 Phase/60Hz Panasonic PLC Alarm Beacon One set of spare fuses NEMA 4X Fiberglass Enclosure NEW Controller SN: TBD The Sewage Lift Station measures approximately S'W X l0'L X l0'H. The new grinder measures approximately SS'H X 11' "W. Duplex NEMA 12 steel (30 x 20 x 8) control panel for 7.SHP, 3PH, 460V service. Accessories to be included are motor CB's, motor starters, HOA switches, run lights, alternator with lead/lag selector, high temperature shutdown circuit with indicator lights. Elapsed time meters, time delay on restart after power fail, lightning arrester, surge capacitor, high water alarm light circuit (flashing), (1) 2 pole 240V, 1PH CB, (2) 1 pole, 115V circuit breakers, power and phase monitor, and 3KVA control and accessory transformer. BACKGROUND Inside the lift station, there is a sewage grinder, "muffin Monster", which grinds the solid waste. This waste is then pumped up hill to the main sewer line on the North side of the institution. The sewage grinder which runs 24 hours a day is no longer properly grinding the waste fed to it by these housing units. When the grinder is not functioning properly the sewage is not ground. The pumps are not capable of pumping solid material. The unground material collects in the pit and causes the floats to become lodged in the material. When the pumps stop pumping the pit will fill and overflow allowing raw sewage to escape the pit and run onto ground. When this overflow occurs, it poses a risk of raw sewage entering the water system, which is against the Environmental Protection Agency's regulations. E.PERIOD OF PERFORMANCE The period of performance for this project is 180 calendar days, after the receipt of the Notice to Proceed. II. CONTRACTOR SECURITY /WORKING REGULATIONS A.WORKING CONDITIONS 1. Working Hours: The working hours for these services will be regularly scheduled for five (5) days a week, between the days of Monday through Friday, with the exception of Government Holidays and weekends. The work hours will be day hours, as to minimally disrupt the orderly function of the institution. Work hours for this project will be between 7:30 a.m. - 4:00 p.m. The contractor will be required to provide a written request for extension of hours or change in work days to the Contracting Officer. Work hours and work days may be altered only with a (24) hour advance approval of the Facilities Manager and Contracting Officer. Delivery of Materials: All materials/equipment required for work on this project is required to be processed by the Contractor and delivered to contractor. Any related deliveries which are delivered to the site can be received between the hours of 8:00 a.m. to 2:00 p.m. Monday through Friday, excluding federal holidays. The contractor is encouraged to receive material and is reminded that there is limited space to store materials on site. At no point will a FBOP staff member receive or sign for a delivery. The contractor is required to notify the COR when product is to be delivered, then be there at the institution to accept and sign for it. Under no circumstances will FCI Memphis or its staff be responsible for the acceptance of any contractor or company deliveries. The contractor shall be responsible for providing their own means of loading and unloading contractor material or equipment. The contractor shall not use the institution entry/driveway for the loading, unloading, or storage of any materials and equipment. The contractor will not impede/block the driveway at any time during or after the work shift. Safety and Personal Protective Equipment: All contractors and employees shall have and wear the required personal protective equipment (PPE) prescribed by industry standards at all times while on the job site. It is the responsibility of the contractor to provide all PPE. If ladders are required, all ladders regardless of the size shall be stored, and secured to a stationary fixture with a chain and lock in a predetermined area, in a way that they cannot be removed. If ladders are required, immediately consult with the COR to ensure the COR can make timely notification to appropriate institution staff. All extension cords regardless of length shall be in good condition with no broken outer insulation and will be secured in a locked construction gang box. Should a system require Lock-out/Tag-out, the system will be required to have both Contractor and FCI Memphis locks on the isolation point to prevent shock. All Lock-out/Tag-out procedures will be in compliance with the institution Lock-out program. TESTING AND ACCEPTANCE The Contractor shall notify COR two (2) days prior to the final system testing and certification so that arrangements can be made to have BOP required staff available to observe testing. A complete plan detailing test procedures must be submitted to the COR in advance for final check out and testing of the complete system. UTILITIES The FBOP will provide minimal electricity service (120V), for battery chargers, radios, small hand tools, etc. In addition, the BOP will provide restroom services and water (potable). The contractor will provide all other supplies and materials needed to complete this project. Walter Carter Date Acting Facility Manager

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS