Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

Sewer Line Installation at Anderson Street

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The City of Loma Linda is managing a project titled Sewer Line Installation at Anderson Street, located in San Bernardino County, California. The primary objective is to improve the reliability and performance of the existing sewer system by upgrading an 8-inch sewer main to a 12-inch SDR 35 PVC sewer main. This installation will take place along Anderson Street, spanning the area between Redlands Boulevard and the Interstate 10 freeway on-ramp, and will connect to existing 12-inch mains at both ends of the project site. Additionally, the scope includes installing a new cleanout for an existing 8-inch sewer lateral that serves a commercial development east of the site to ensure proper maintenance access. The project is classified under NAICS code 237110 and is being executed within the existing public right-of-way. Administrative oversight is provided by City Manager T. Jarb Thaipejr. From an environmental standpoint, the project is exempt from certain fees under California environmental codes 15301 and 15302, as it involves minor alterations and negligible expansion of existing public utility infrastructure. The project was forecasted for August 2026, and the lead agency has filed the necessary environmental documentation with the California Department of Fish and Wildlife.

General Info

City of Loma Linda to upgrade 8-inch to 12-inch PVC sewer main on Anderson Street, add cleanout, bid in August 2026.

Agency

California → City of Loma Linda

NAICS

237110 - Water and Sewer Line and Related Structures ConstructionView NAICS

Place of Performance

Anderson Street, between Redlands Boulevard and Interstate 10 Freeway on-ramp, Loma Linda, CA, 92354

Set-Aside

NONE

Documents

(1)

NOE Sewer Pipe Project on Anderson Street - Environmental Document Filing Fee Cash Receipt

PDFreceipt

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → City of Loma Linda
Contacts1 person available
OfficeN/A
Organization / Agency
California → City of Loma Linda
Office AddressN/A
Contacts
T. Jarb ThaipejrCity Manager

Full Description

Show more
The project consists of upgrading an existing 8-inch sewer main to a 12-inch SOR 35 PVC sewer main along Anderson Street between Redlands Boulevard and the Interstate 10 (1-10) freeway on-ramp. The upgraded 12-inch sewer main will connect to the existing 12-inch sewer main on Redlands Boulevard and to the existing 12-inch sewer main adjacent to the 1-10 freeway. The project also includes the installation of a new cleanout for an existing 8-inch sewer lateral that serves an existing commercial development located east of the project site. The cleanout will be installed adjacent to the proposed 12-inch sewer main to provide maintenance access to the existing lateral.

Similar Contracts

Same NAICS industry code

NAICS: 237110
New
Inland Feeder/SBVMWD Foothill PS Intertie, Stage 1
Solicitation # inland-feedersbvmwd-foothill-ps-intertie-stage-1
The Inland Feeder/SBVMWD Foothill PS Intertie, Stage 1 project in Highland, California, involves the installation of extensive water infrastructure for the Metropolitan Water District of Southern California. The scope of work includes furnishing and installing approximately 2,150 linear feet of 54-inch to 66-inch diameter steel pipe and 200 linear feet of 144-inch diameter steel pipe. The project requires the installation of both contractor-furnished and Metropolitan-furnished valves, including 54-inch and 132-inch diameter valves and tie-ins ranging from 54 to 145.5 inches. Additional structural requirements include the construction of four surge tanks, two valve vaults, an air compressor yard structure, and various drainage improvements. The technical scope further encompasses electrical upgrades, instrumentation and controls, piping systems, and specialized civil works such as the excavation of cobbles and large boulders, welding, disinfection, and surface restoration. This solicitation, issued by James W. Fowler Co., is open to small businesses, including SBA-certified service-disabled veteran-owned small businesses, minority business enterprises, and women business enterprises. Bids and subcontractor pricing must be submitted by September 29, 2026, with all negotiations finalized 24 hours prior to the bid opening. The project encourages the use of apprentices and provides specific support for M/W/DBE subcontractors regarding bonding, insurance, and material procurement.
James W. Fowler Co.

POSTED

about 2 hours ago

DEADLINE

in 10 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS