Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on March 22, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

SOLE SOURCE - ENVIRONMENTAL CONTROL UNITS/TEMPERATURE CONTROL OF SHELTERS OR CHAMBERS IN HARSH ENVIRONMENTS

Awarded
N0016417Q0004Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 10 hours ago

DEADLINE

in 18 days
NAICS: 333415
New
DIBBS
41--COOLER UNIT,AIR
Solicitation # SPE8E8-27-T-0446
Solicitation SPE8E8-27-T-0446 is a fixed-price contract issued by DLA Troop Support Construction and Equipment for the procurement of one air cooler unit, identified by NSN 4130012251590 and part number FCU-H3-3.5KW-LVP from Engineered Coil Company. The requirement is designated as a critical application item. Delivery is required within 153 days after the order is placed, with a need ship date of April 12, 2027, and an original required delivery date of October 19, 2027. The shipment is designated as FOB Origin under the First Destination Transportation program, with the final delivery destination being the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to technical and quality requirements via the DLA Master List (RA001) and specific packaging and marking standards, including MIL-STD-2073-1E and MIL-STD-129. It prohibits the intentional addition of mercury or mercury-containing compounds unless specifically exempted for functional use. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and payment. Compliance with various FAR and DFARS clauses is required, specifically those regarding the Buy American Act, safeguarding covered defense information, and prohibitions on covered defense telecommunications equipment. Inspection and acceptance will occur at the destination.
DDSP NEW CUMBERLAND FACILITY

POSTED

about 10 hours ago

DEADLINE

in 11 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

IN

Set-Aside

NONE

Documents

1

Noncompetitive Procurement Justification - Environmental Control Unit (P/N IQ8000HA)

PDF, Low priorityjustification-and-authorization
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseAwarded
Posted

Combined Synopsis

Justification (J&A)

Justification & Approval published

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Nswc Crane
Contacts1 person available
OfficeCRANE, IN, 47522-5001, USA
Office AddressCRANE, IN, 47522-5001, USA

Full Description

Show more
N0016417Q0004 -SOLE SOURCE - ENVIRONMENTAL CONTROL UNITS/TEMPERATURE CONTROL OF SHELTERS OR CHAMBERS IN HARSH ENVIRONMENTS - FSC 4120 - NAICS 333415 Issue Date: 22 March 2017 Closing Date: 27 March 2017 Time 3:00 P.M. EDT The proposed contract action is for supplies or services for which the Government intends to solicit and negotiate with only one source and source's authorized distributors, Ice Qube, Inc. 141 Wilson Ave., Greensburg, PA 15601under the authority of FAR 6.302-1(a) (2).The OEM owns all proprietary data for this equipment. This is being sole sourced because the items are replacement parts for current fielded systems. All other offerors may submit a quote that will be reviewed by the Government. However, a determination by the Government not to compete with this proposed contract based upon responses to this solicitation is solely for the purpose of determining whether to conduct a competitive procurement. Naval Surface Warfare Center (NSWC) Crane Division intends to solicit, negotiate, and enter into a Firm Fixed Price Commercial Supply Contract IAW FAR 13, Simplified Acquisition Procedures for the following procurement: CLIN0001 Environmental Control Unit QTY 11 Specification for Environmental Control Unit (ECU) I1B1 Fixed Site Shelter SWXQ179219 1. Mechanical Dimensions: a. Maximum Height shall not exceed 52.125" (-2.00" / +0.000") b. Maximum Width shall not exceed 18.00" (-2.00" / +0.00") c. Maximum Depth shall not exceed 11.00" (-2.00" / +0.00") d. Hot side air inlet shall be located on the left side of the ECU cabinet. e. Hot side air outlet shall be located on the front side of the ECU cabinet. f. Cold side air inlet and outlet shall be located on the back side and in the upper quadrant of the backside panel, and the cold side inlet shall be located below the cold side outlet. g. Power cord and access to remote control shall be located on the backside. Note: Pictorial diagram is provided for reference use only. The ECU height and hot side air inlet and outlet positions, cold side air inlet and outlet positions, power cord location, and remote control interface location are critical to the I1B1 Receiver / Transmitter (R/T) system integration with the I1B1 Fixed Site Shelter. For reference purposes, the ECU "back" shall be the panel which mounts to the R/T pod and through which the conditioned air passes. Left, right, and front sides are defined relative to the back side, accordingly. Positions of conditioned air inlets and outlets are critical to R/T pod and include electronics air flow dynamics. 2. Performance Characteristics: a. Nominal cooling capacity at standard temperature, humidity, and pressure: 8,000 BTU/HR, minimum b. HFC refrigerant (reference Air Force Pamphlet 32-7089 Section A12.3.2 - Alternates to R-22). This pamphlet is provided as Government Furnished Information (GFI). c. Power Source: 120 Vac, Single Phase, 60 Hz d. Maximum Current (including starting current); 15 Amperes e. Heating capacity: 400 Watts (nominal) f. Maintain NEMA 4X environmental protection rating. g. Anti-Corrosion protection applied to the copper condenser coils. (To protect against salt-air environment) h. Requires built-in condensate evaporation. i. Requires remote (auxiliary) control and display unit, installed. j. Unit shall be designed for sustained high ambient temperature operation. The ECU shall continue to operate at +135� F ambient temperature. k. Based upon the R/T equipment suite heat dissipation requirement, the ECU shall be capable of developing a minimum of 6,400 BTU/HR cooling capacity while maintaining return air at +105� F, against ambient air temperature of +130� F. 3. Reliability and Maintainability Requirements: a. The mean time to perform preventive maintenance shall not exceed 15 minutes. b. The mean time between critical failures shall be greater than or equal to: 50,000 hours. (Critical failures are defined as failure of the compressor, fans, condenser, or controller.) Inspection and Acceptance is to be at destination with deliver F.O.B. Destination: NSWC Crane, IN 47522-5001. To be eligible for award of a Government contract, contractors must be properly registered in the System for Award Management (SAM). The link to the website is https://www.sam.gov All changes to the requirement that occur prior to the closing date will be posted in FedBizOpps. It is the responsibility of interested vendors to monitor the FedBizOpps for amendments that may be issued to this solicitation. For changes made after the closing date, only those offerors that provide a proposal will be provided any changes/amendments and considered for future discussions and/or award. No hard copies of the solicitation will be mailed. Quotes must be submitted in the format specified in the solicitation. It is the responsibility of the offeror to submit offers to the POC at NSWC Crane. The POC is Ms. Theresa Jones, Code 0253, Telephone +1 (555) 000-0000. Offers may be emailed to contact@example.gov. All required information must be received on or before 27 March 2017. Time 3:00 P.M.

More opportunities from Department Of Defense → Nswc Crane

Same awarding agency

NAICS: 541380
New
Federal
ENVIRONMENTAL QUALIFICATION TESTING (EQT)
Solicitation # N0016427SNC12
The US Navy, through NSWC Crane, is issuing a Request for Information (RFI) under announcement N00164-27-S-NC12 to identify qualified contractors capable of performing Environmental Qualification Testing (EQT) and electromagnetic compatibility (EMI) testing. The objective is to verify that the Combined All-Domain Command and Control System Afloat (CAC2S Afloat) Data Processing Assembly and Workstation Mount meet naval shipboard survival and operational requirements following a hardware technology refresh. Testing must adhere to several military standards, including MIL-DTL-901E for shipboard shock, MIL-STD-167-1A for vibration, MIL-STD-461G for electromagnetic interference, MIL-STD-810H for environmental engineering, and MIL-STD-1399 for shipboard power interfaces. Interested parties must be registered in the System for Award Management (SAM) and the Joint Certification Program (JCP) to access the full Statement of Work. The government is seeking capabilities and budgetary estimates from commercial firms, non-profits, and academic institutions, with a strong encouragement for small and disadvantaged businesses to respond. Submissions, which may include a white paper of up to five pages and company literature, are due by November 18, 2026. While this RFI is used for market research to determine if the effort should be pursued via sole source or competitive procurement, the government explicitly states that no funding is currently available and this notice does not constitute a formal solicitation or commitment to award a contract.
Testing Laboratories and Services

POSTED

about 10 hours ago

DEADLINE

in 20 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS