Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Energy was posted on January 29, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

SOURCES SOUGHT/REQUEST FOR INFORMATION (SS/RFI) FOR CLEANING, SURFACE PREPARATION, AND RECOATING SERVICES OF WATER TANKS AT THE SAVANNAH RIVER SITE NEAR AIKEN, SOUTH CAROLINA

Closed
SRR-SCM-2021-00009Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
26350 Lynchburg, VA - CSO 70 Sewer Improvements
Solicitation # 2027-027
Cleary Construction is soliciting quotations from certified Disadvantaged Business Enterprises for the City of Lynchburg CSO 70 Sewer Improvements project in Virginia, identified by solicitation number 2027-027. This opportunity is open to various small business set-asides, including SBA certified Veteran Owned, Service-Disabled Veteran Owned, Women-Owned, and HUBZone small businesses. Interested firms must submit their responses by December 4, 2026. The scope of work involves comprehensive sewer infrastructure improvements, including the open-cut installation of PVC and DIP sewer lines ranging from 6 to 30 inches in diameter. Key technical requirements include the installation of standard and doghouse manholes, interior drop assemblies, a CSO regulator fit out, and 24-inch diameter trenchless crossings with associated launch and receiving shafts. Additional project deliverables include the implementation and maintenance of a Stormwater Pollution Prevention Plan, geotechnical instrumentation and monitoring, and the maintenance of flows and bypass for all pipes and manholes during construction. General project requirements include clearing and grubbing of wooded areas, seeding, fine grading, and select tree removal. Due to the project location and nature, contractors must provide railroad insurance. The bid schedule further accounts for extra depth excavation and the abandonment of existing pipes and manholes. All inquiries and quotations should be directed to John Connelly at Cleary Construction.
Cleary Construction, Inc.

POSTED

about 4 hours ago

DEADLINE

in about 1 month
NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with a project estimate of 16,690,000 dollars. The scope of work involves the installation of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key deliverables include the construction of a new wet well and valve vault, the demolition of existing pumps and piping, and the delivery of a fully operating facility equipped with mechanical and electrical systems, a generator, odor control equipment, and stormwater facilities. The project also requires associated site work, including exploratory drilling, rock excavation, and grading. The contract is governed by EJCDC standard general and supplementary conditions, with technical specifications spanning divisions 00 through 44. Award will be granted to the responsible bidder submitting the lowest responsive bid, with evaluation based on qualifications, financial ability, and adherence to submission requirements. Bidders must provide a signed bid form, bid security, and mandatory MWBE documentation, including a Good Faith Efforts Form and Table A, to meet participation goals of 10.9 percent for EPA MBE and 10 percent for the State of North Carolina. Contract administration is managed by the City of Belmont with Willis Engineers serving as the project engineer. Payment is processed via Applications for Payment, with a 30-day payment term following the engineer's recommendation.
Don Moorhead Construction, Inc.

POSTED

about 4 hours ago

DEADLINE

in 11 days

General Info

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Aiken, SC, 29808, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

The notice title changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Energy → Savannah River Remediation-Doe Cntr
Contacts1 person available
OfficeAiken, SC, 29808, USA
Office AddressAiken, SC, 29808, USA
Contacts
Ashley Hannah

Full Description

Show more
PURPOSE The purpose of this inquiry is to determine your interest and qualifications as a possible Offeror to perform surface preparation and recoating services in the Effluent Treatment Project (ETP) at the Savannah River Site (SRS). In addition, this inquiry also provides an opportunity for SRR to ask pertinent questions of potential subcontractors. This potential Design/Build subcontract will be performed with labor whose wages are subject to the Davis-Bacon Act. GENERAL DESCRIPTION OF SERVICE Provide all labor, materials, equipment and supervision to do cleaning, surface preparation and recoating the exterior of three (3) treated water tanks at the Effluent Treatment Project (ETP), at the Savannah River Site. ETP is a Wastewater Treatment facility located on the Savannah River Site (SRS), a U.S. Department of Energy (DOE) site located near Aiken, SC. Savannah River Remediation (SRR) operates ETP under contract to the DOE. ETP has three (3) Treated Water (TW) storage tanks each 30' high and 30' diameter (160,000 gallons). The tanks were installed in the mid-1980's and are approximately 30+ years old. The tanks were originally coated with epoxy primer and coating. The TW tanks are showing signs of deteriorating paint and some surface corrosion (rust). Recoating of the tanks is necessary to extend the life of the tanks and prevent further degradation. The ETP TW tanks are integral components of the ETP Treated Water System. SOURCES SOUGHT/REQUEST FOR INFORMATION (SS/RFI) DISCLAMER SRR will use the information obtained in your response to this SS/RFI to determine your firm's ability and interest in performing this service. This SS/RFI is for INFORMATIONAL PURPOSES ONLY. EXPENSES RELATED TO SOURCES SOUGHT/REQUEST FOR INFORMATION (SS/RFI) SUBMISSIONS This SS/RFI does not commit SRR to issue a future solicitation for these services or to award a subcontract, nor to pay any costs incurred in the development and submission of any response. Funds are not presently available for any subsequent procurement action. SOURCES SOUGHT/REQUEST FOR INFORMATION (SS/RFI) SUBMITTAL INSTRUCTIONS The response should include your overall qualifications and proven capabilities in supplying these types of services. The information specified below is requested. Organization and Experience Demonstrate that your firm has sufficient resources and experience, or if you propose to perform the potential subcontract by use of a partnering agreement with another firm, or with the use of sub-tier subcontractors/suppliers. The Subcontractor shall have at least 5 years prior experience painting the exterior of water storage tanks. Quality Assurance Program Demonstrate your firm's Quality Assurance program. The Subcontractor shall provide National Association of Corrosion Engineers (NACE) certified Level 1, 2 or 3 inspectors. REQUIREMENTS Potential Offerors need to be aware of SRR Subcontract Requirements as follows: SRR is a Davis-Bacon Act worksite, and Subcontractors and Lower-tiers Subcontractors are required to be signatories to the Project Labor Agreement (Union Labor). Proposal, Payment and Performance bonds will be required. Environmental Safety and Health Evaluation Worksheet for the past three (3) calendar years will be required with OSHA 300 logs to support. SRR requires an Experience Modification Rate (EMR) of 1.0 or less and a Total Recordable Case (TRC) rate of 3.4 or less. Potential Federal Budget constraints will be presented within the request for proposal (RFP). Representations and Certifications will be required and will be part of the RFP. Small Business Subcontracting Plans will be required of Large Business Offerors. North American Industry Classification System (NAICS): 237110 SUBMISSION OF INTEREST Please respond via email to contact@example.gov by 12:00pm on February 12, 2021. Procurement Reference Documents such as standard terms and condition, standard representations and certifications, subcontractor safety program guidance, and other forms are located at the Savannah River Site web address: http://www.srremediation.com/business.html. Offerors can review typical Davis-Bacon Subcontract documents at: SRRemediation.com, then to Business Opportunities, then to Documents and Forms.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS