The U.S. Army Corps of Engineers, Nashville District, is conducting market research to identify qualified contractors capable of supplying and delivering a comprehensive range of electrical, mechanical, and safety components for a critical infrastructure project. The requirement includes two 10kVA static inverters, isolation breakers, a bypass transformer, multiple panelboards for DC and AC systems, a 450kW outdoor diesel generator load bank, a manual transfer switch, new conduits and cables, environmental monitoring devices such as a hydrogen sensor and smoke detector, battery isolation and charging breakers, a fire-rated steel door and glass assembly rated for three hours, a fire-rated HVAC damper with fusible links, ductwork for a new 50-foot branch with four right-angle turns, a spark-resistant centrifugal exhaust fan rated for 285 CFM, and a combination emergency wash station with eye wash and deluge shower capabilities. All work must be performed by contractors providing full turnkey support including personnel, equipment, materials, transportation, supervision, and installation. This initiative is not a solicitation but a sources-sought notice under NAICS code 335313 for Switchgear and Switchboard Apparatus Manufacturing, with a size standard of 1,250 employees. Respondents are required to provide basic company information including their name, CAGE code, point of contact, small business status, ability to deliver expedited, whether they manufacture the specified components, prior experience with USACE or hydroelectric dam projects, and their intent to submit a quote if the requirement is formally advertised. Responses must be submitted by August 10, 2026, to the designated points of contact at the Nashville District. No reimbursement will be provided for costs incurred in responding to this information request, and the resulting data will be used solely to determine market readiness and competition for an anticipated future procurement.
General Info
Agency
NAICS
Place of Performance
TNSet-Aside
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Response Deadline
Organization & Contact Information
Full Description
Request for Information: The U.S. Army Corps of Engineers, Nashville District is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.
This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Requirement: This project is for the supply and delivery of components identified in this request. The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items to perform the work herein.
a. Two 10kVA static inverters (IV1, IV2), four isolation breakers, and one 10kVA bypass transformer.
b. One 125VDC panelboard, one 120VAC preferred AC panelboard, one emergency lighting panel board and one preferred AC sub-panel including all breakers, ancillary equipment, and associated bus.
c. One 450kW outdoor diesel generator AC load bank and one 480V manual transfer switch.
d. New conduits and cables.
e. One hydrogen sensor, one air flow switch, one differential pressure switch, one smoke detector and three warning lights.
f. One battery disconnect switch, one automatic transfer switch, and DC load bank plug.
g. One battery breaker, two battery chargers breakers, and one load bank breaker.
h. Level 4 Maximum Duty 3-hour fire-rated steel door and frame assembly with a 3-hour fire-rated glass window.
i. One 3-hour fire rated HVAC damper for a 10"x8" duct and all the hardware necessary for it including 2 spare fusible links.
j. Sufficient ductwork materials for the addition of a new ductwork branch off of an existing 10"8" supply duct and running 50 feet, including 4 right angle turns.
k. One centrifugal exhaust fan with a spark resistant motor to exhaust a minimum of 285 CFM of air and mounting equipment to mount the fan to an exterior wall.
l. One combination emergency wash station with eye wash and deluge shower capabilities.
NAICS: The anticipated NAICS code for this requirement is 335313, Switchgear and Switchboard Apparatus Manufacturing, size standard of 1,250 employees.
Survey: Please send responses to the Market Survey to R. Brent Hester at Richard.B.Hester@usace.army.mil and Kenyanna Jennings at Kenyanna.L.Jennings@usace.army.mil
- Name of Firm:
- CAGE:
- Point of Contact (include email address)
- Are you classified as a small business under the following NAICS codes? If so, do you fall into a sub-category (e.g. HubZone, 8(a), SDVOSB, WOSB, etc.)?
- 335313, Switchgear and Switchboard Apparatus Manufacturing – 1,250 employees.
- If this requirement is advertised, do you anticipate submitting a quote?
- Can your company provide expedited delivery of equipment?
- Does your company manufacture these components?
- Has your company completed work for USACE?
- Has your company supplied equipment to hydroelectric dams?
- Please provide any additional information you feel is necessary.