Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Agriculture was posted on July 18, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Supply and Install Chemical Storage Building

Closed
12405B22Q0240Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
F-15EX 8-Bay Maintenance Hangar Complex-Industry Day
Solicitation # W50S8527H1CU0
The National Guard Bureau is seeking market intelligence for the construction of an aircraft maintenance hangar complex at Selfridge Air National Guard Base in Harrison Township, Michigan. This project supports 21 Primary Aircraft Authorization F-15 EX aircraft and is estimated to have a magnitude between 150 million and 200 million dollars. The scope includes the demolition of buildings 3, 5, 117, and 120, with new parking constructed in the footprints of buildings 117 and 120. The construction may be executed in three phases: Hangar 1, a 2-bay corrosion control and fuel cell hangar; Hangar 2, a 4-bay maintenance hangar; and Hangar 6, a 2-bay munitions and training facility. The project also requires necessary utility and infrastructure upgrades. The government is considering a fixed-price agreement utilizing an Other Transaction Agreement under the authority of 10 U.S.C. 2808a, with funding potentially provided in annual phases of approximately one-third of the total cost. Technical requirements include compliance with DoD antiterrorism and force protection standards, adherence to Air Force and base design standards, and specialized foundations to meet flood plain requirements. Design is anticipated to be 100 percent complete by early 2027. This notice is for planning purposes only and is not a formal solicitation. Interested firms under NAICS code 236210 must provide company details, bonding capacity, and evidence of experience with aviation facilities and constrained-site construction to the designated points of contact by the response deadline of December 1, 2026.
W7NF Uspfo Activity Miang 127

POSTED

1 day ago

DEADLINE

in about 1 month
NAICS: 236210
New
SLED
Facilities & Parks New Supply Warehouse Building
Solicitation # ITB FM 04-27
The Board of County Commissioners of Okaloosa County, Florida, is soliciting bids under ITB FM 04-27 for the construction of a new 9,000 square foot metal supply warehouse for the Facilities and Parks Department located at 5489 Old Bethel Road in Crestview. The project involves comprehensive site preparation and construction, including the installation of energy-efficient HVAC systems, electrical and plumbing work, and telecommunications wiring. All work must comply with the 2023 8th Edition Florida Building Code, ADA standards, and OSHA regulations, with specific structural requirements to withstand 160 MPH ultimate wind speeds. A fire alarm system is explicitly not required for this project. Bids must be submitted electronically via OpenGov by November 4, 2026, at 3:00 pm CST. The contract will be awarded to the responsive and responsible vendor with the lowest bid, though the County reserves the right to negotiate the most advantageous agreement. The selected contractor must provide a dedicated project manager and furnish both bid and performance bonds. The project timeline is 12 months from the notice to proceed. Payment will be processed through the County Finance Office in accordance with the State of Florida Local Government Prompt Payment Act, contingent upon annual appropriation. For projects involving federal grant funding, contractors must be registered in SAM.gov and comply with Buy America and Trafficking Victims Protection Act requirements.
Facilities & Parks

POSTED

6 days ago

DEADLINE

in 6 days

General Info

NAICS

236210 - Industrial Building Construction

Place of Performance

New Orleans, LA, 70124, USA

Set-Aside

SBA

Documents

2

Commercial+Items+Clauses+FAC+2020-01+eff.+11-12-19+under+%24250k+%2811-15-2019%29.docx

DOCX

SOW.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

3 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Jul 22, 2022 to Jul 27, 2022. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Agriculture → USDA Ars Sea Aao Acq/per Prop
Contacts1 person available
OfficeSTONEVILLE, MS, 38776, USA
Office AddressSTONEVILLE, MS, 38776, USA

Full Description

Show more
A site visit has been scheduled for this project. It will be held on Wednesday, July 20th, at 2:00 PM CST. Please send the company name and the name of personnel requesting to attend to contact@example.gov by 4:00PM Tuesday, July 19th CST. This solicitation has been extended until Wednesday July 27, 2022. Questions can be provided until Monday, 25, 2022. Question 1: Please confirm that a Factory Mutual Approval label is required with NRTL Certified components as the government requires for their projects. Please advise who was used as the basis of design since these are not typical specifications required for FM Approved prefabricated chemical storage buildings shipped to New Orleans, LA. Answer 1: While doing market research, we found multiple vendors and manufacturers that could provide appropriate and acceptable buildings for our needs. All these buildings were indicated to have the FM approval rating. It should not be a problem to meet all our specs and obtain the FM approval label, however we are not requiring all those standards to be met. Question 2: You referenced a 1 fire rated partition wall needed. The only option for partition walls is non-fire-rated, 2 hour fire-rated and 4 hour fire-rated partition walls approved for FM approved buildings. Please confirm what fire-rating is required for the partition wall since a 1 hour fire-rated partition wall is not an NRTL Certified option and not approved for FM Approved buildings. Answer 2: The - 1 mentioned in the SOW was indicating a quantity of ONE partition wall and was not indicating fire rating. We require that the fire partition wall be rated at three hours. Question 3: 4 hour fire-rated construction should always be bi-directional fire protection for FM Approved buildings since uni-directional fire-rated walls do not protect from fires entering the buildings from outside sources. Answer 3: We require a uni-directional system as a basic bid or a minimum. Question 4: The 140 MPH wind load requirement will need to be required for the entire building including all walls, ceiling and sump with wind rated air inlets and double doors required to meet the wind load needed. Without these components, your building will not be wind rated and the door will have increased corrosion since standard double doors have weep holes for condensation and wind will cause moisture up the weep holes and the door to corrode quickly near the bottom edge. This will reduce the life of your building considerable and the double door cannot be replaced in the field when corrosion appears since the frame is welded into place per FM requirements. Adding wind load structure to the walls only will not meet the wind load requirement for New Orleans, LA and the building cannot be labeled with a 140 MPH wind load per code compliance. Answer 4: The proposed building is required to meet all federal, state, and local codes and to be stamped by a PE licensed Engineer. Question 5: A PE stamped submittal should be included to validate the 140 MPH wind load requirement has been met by supplying PE Stamped drawings and calculations by a LA licensed PE. Without this requirement any one can state that their building meets the wind load requirement and you have no way to validate the option since it is in the wall structure and cannot be confirmed by visual inspection at delivery with no submittal drawings included to validate your requirements. Answer 5: We are aware of the PE stamp requirement. This must be handled and completed by the contractor and the price included in the bid. Only the contractor/manufacturer has access to the detailed plans and drawings for the building, which will be required for the PE stamp. Any submittal for consideration must have the stamp present. Question 6: Please confirm the building size needed since your only provided the pad size and not the storage requirements needed. Without listing the building size and storage capacity needed, anyone can quote a much smaller building than needed and be compliant to your specification since only maximum building dimensions are listed. This not recommended if you want bidders to quote comparable prefabricated chemical storge buildings. Answer 6: Building size varies between manufacturers, so we cannot specify exact building size. We would like the largest building that fits appropriately on our concrete pad, considering required tie downs and any other exterior accessories that require space. The concrete pad is 15'11 x 9'4. Equipment research shows that buildings tend to come in ~16 and ~14 lengths. A 16 building will NOT fit on the pad, so we will likely need a building one size down, in the 14 range. Contractors are encouraged to measure the existing pad during the site visit and propose the largest unit that can fill pad. Question 7: You will need to specify that a 2.5 fire department hose connection be included to provide the connection to the sprinklers to deluge the building. Without this option, there is no way for the fire-fighting response for deluge. Also, a sump drain with ball check value is typically needed to avoid overflowing the sump during firefighting deluge. Answer 7: The sprinkler system must have an exterior 2-1/2 NHT (National Hose Thread) brass fitting with cap. Question 8: Mechanical ventilation will be required since natural ventilation will not provide the 6 air changes per hour required for storing flammables. Your specification references passive ventilation and a mechanical ventilation system is required for storing flammables/combustible to remove the vapors before personnel enter the building. Answer 8: An explosion proof mechanical exhaust fan must be included. The system must be able to automatically shut down if a fire occurs. Question 9: Please confirm how much stainless shelving required since it was not included in your specification. Answer 9: We will need 9 shelves per side of the unit, for a total of 18 shelves for the entire building. (additional shelving is acceptable if that is standard) Question 10: Please confirm the electrical supply voltage and phase available since it was not included in your specification. Answer 10: Electrical connection is standard 120/208 V, single phase. We do not require a step down transformer. Question 11: Please confirm that your specification includes a horn and strobe alarm for the dry chemical fire suppression system since it was unclear what the alarm was supporting from the statement about bell and lights. The dry chemical fire suppression system comes standard with a bell but will be replaced if a horn and strobe are needed. Answer 11: The system must be equipped with a means for remote annunciation system, which could include a bell, a horn, and a strobe light. There must be some sort of exterior audible alarm. This is a Combined Synopsis/Solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. Solicitation number 12405B22Q0240 is issued as a request for quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83. The associated NAICS code is 236210 (Industrial Building Construction), with a small business size standard of $39.5 Million. USDA, ARS, SRRC 1100 Allen Toussaint BLVD New Orleans, LA 70124 Is looking for procurement for Supply and Install Chemical Storage Building that fits into the associated Statement of Work. The Government anticipates award of a Firm Fixed Price contract. Each offer must show a breakdown giving price of each element, provide descriptive literature or information showing that the offered items meet all parts of the Equipment Requirements. Vendors responding to this announcement shall submit their quote in accordance with FAR 52.212-1. Submission of quote shall include the following: (1) Technical Specifications and (2) Price (to include shipping). Electronic submissions are preferred. Please email all quotes to contact@example.gov. NO LATE QUOTES WILL BE ACCEPTED. The basis for award is Lowest Price Technically Acceptable. "LPTA" means the expected outcome of the acquisition that result from selection of the technically acceptable proposal with the lowest evaluated price. Pursuant to FAR 52.212-2, the criteria for evaluation are: (1) Technical Specifications, (2) Price, and must also have satisfactory Past Performance. INSPECTON AND ACCEPTANCE TERMS: Supplies will be inspected by requiring office's technical representative and accepted at destination. The following Federal Acquisition Regulation (FAR) and the Department of Agriculture Acquisition Regulation (AGAR) provisions and clauses apply to this acquisition: FAR 52.202-1 Definitions; FAR 52.203-5 Covenant Against Contingent Fees; FAR 52.203-6 Restriction on Subcontractor Sales to the Government; FAR 52.203-7 Anti-Kickback Procedures; FAR 52.203-17 Contractor Employee Whistleblower Rights and Requirement to Inform Employees of Whistleblower Rights; FAR 52.204-7 Central Contractor Registration; FAR 52.204-10 Reporting Executive Compensation and First-Tier Subcontract Awards; FAR 52.204-14 Service Contract Reporting Requirements; FAR 52.204-16 Commercial and Government Entity Code Reporting; FAR 204-17 Ownership or Control of Offeror; FAR 52.204-18 Commercial and Government Entity Code Reporting; AGAR 452.204-70 Inquiries; FAR 204-19 Incorporation by Reference of Representations and Certifications; FAR 52.209-6 Protecting the Government's Interests when Subcontracting with Contractors Debarred, Suspended or Proposed for Debarment; FAR 52.209-10 Prohibition on Contracting with Inverted Domestic Corporations; AGAR 452.209-71 Assurance Regarding Felony Conviction or Tax Delinquent Status for Corporate Applicants; FAR 52.212-1 Instructions to Offers-Commercial Items; FAR 52.212-2 Evaluation- Commercial Items (filled in as follows: Technical specifications and price); FAR 52.212-4 Contract Terms and Conditions-Commercial Items; FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes of Executive Orders-Commercial Items; FAR 52.216-24 Limitation of Government Liability; FAR 216.25 Contract Definitization; FAR 52.219-6 Notice of Total Small Business Set-Aside; FAR 52.219-28 Post Award Small Business Program Re-representation; AGAR 452.219-70 Size Standard and NAICS Code Information; FAR 52.222-3 Convict Labor; FAR 52.222-17 Non-displacement of Qualified Workers; FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity Employment; FAR 52.222-36 Affirmative Action for Workers with Disabilities; FAR 52.222-50 Combating Trafficking in Persons; FAR 52.223-18 Encouraging Contractor Policy to Ban Text Messaging While Driving; FAR 52.225-13 Restrictions on Certain Foreign Purchases; FAR 52.225-25 Prohibitions on Contracting with Entities Engaging in Certain Activities or Transactions Relating to Iran-Reps and Certs; FAR 52.232-1 Payments; FAR 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration; FAR 52.232-39 Unforceability of Unauthorized Obligations; FAR 52.233-2 Service of Protest; FAR 52.233-3 Protest After Award; FAR 52.233-4 Applicable Law for Breach of Contract; FAR 52.243-FAR 52.244- 6 Subcontractors for Commercial Items; FAR 52.252-1 Solicitations Provisions Incorporated by Reference; FAR 52.243-1, Alternate 1, Changes - Fixed Price; FAR 52.243-4 Changes; FAR 52.249-2 Termination for Convenience of the Government (Fixed Price); 52.252-2 Clauses Incorporated by Reference. To be eligible for an award, all contractors must be registered in the System for Award Management (SAM). A contractor can contact SAM by calling +1 (555) 000-0000 or e-mail at www.sam.gov. NO EXCEPTIONS. A DUNS (Dun and Bradstreet) number is required in order to register. All invoices shall be submitted and paid electronically. Quotes must be received no later than July 22, 4:00pm Central Standard Time. Questions regarding this combined synopsis/solicitation are due no later than 3:00 PM CST on Wednesday July 20, 2022. Answers to any questions received by that time will be posted as an amendment to this combined synopsis/solicitation.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS