Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 22 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on August 14, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Supply of a Stainless Steel Jacketed Radial Arm Door Autoclave for CL3 Laboratory

Closed
23-58043Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → National Research Council of Canada

NAICS

N/A

Place of Performance

*Canada, CAN

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → National Research Council of Canada
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → National Research Council of Canada
Office AddressN/A
Contacts
Carol CooperPoint of Contact

Full Description

Show more
The Human Health Therapeutics Research Center, National Research Council Canada has a requirement for the supply of quantity:1 double sided (pass-through), radial arm locking door, stainless steel jacketed sterilizer (steam autoclave) with a bioseal to meet the requirements of our Containment Level 3 operating license as issued by the Public Health Agency of Canada (PHAC) and the Canadian Food Inspection Agency (CFIA). This is to replace an outdated and deteriorating existing unit. This equipment must have a stainless steel jacket, radial arm locking doors (dual sided), bioseal (To ensure the CL-3 lab is contained, CL-3 autoclaves are equipped with a biological sealing flange or bio-seal. A bio-seal provides separation and a positive seal between the hazardous side and safe side, which is imperative for the safety of personnel. The bio-seal shall be comprised of a steel or stainless- steel plate that is continuously welded to all four sides of the sterilizer. It extends out beyond the frame of the sterilizer to which the installer then attaches the barrier – a durable silicone gasket. The gasket extends between the barrier flange and the wall and is secured in place by stiffening bars to ensure a leak-tight fit. All penetrations through the barrier flange (for either wiring or plumbing) are fully potted to prevent air leaks) suitable for CL3 containment laboratories such that it meets the requirements as outlined in the current Edition (3rd) of the Canadian Biosafety Standard (CBS).