Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

Supply of Military CYPRES-2 AAD Units with LTM

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract involves the procurement of ten Military EC CYPRES-2 I-Pin Changeable units equipped with Life Time Monitoring for the Department of Defense, specifically under the FA4861 99 Cons Lgc agency. These automatic activation devices are designed for military free-fall parachuting operations to guarantee parachute deployment at a preset altitude. The contract falls under NAICS code 334510 and was posted on August 13, 2026, with a response deadline of August 26, 2026. Performance for this requirement is designated for the location associated with zip code 89191.

General Info

Procurement of ten Military EC CYPRES-2 units for the Department of Defense.

Agency

Department Of Defense → FA4861 99 Cons LgcView Agency

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus ManufacturingView NAICS

Place of Performance

0, NV, 89191, USA

Set-Aside

NONE

Documents

This scope was carved out of F3G5BA6191AG01.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Notice of Intent to Sole Source – 414 CTS CYPRES AADS

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4861 99 Cons Lgc
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Defense → FA4861 99 Cons Lgc
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supply of ten Military EC CYPRES-2 I-Pin Changeable units with Life Time Monitoring (LTM) for use in military free-fall parachuting operations to ensure automatic parachute deployment at preset altitude.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → FA4861 99 Cons Lgc

Same awarding agency

NAICS: 562910
New
Federal
57 MXG Paint Booth Carbon Filter Replacement
Solicitation # F3G3AA6161AQ01
Solicitation FA486126Q0023 is a combined pre-solicitation and solicitation issued as a Request for Quote for commercial services. This is a Total Small Business set-aside under NAICS code 562910 (Remediation Services) for a Firm Fixed Price contract. The requirement involves providing non-personal services for the environmental containment, extraction, and replacement of active-carbon filtration media within industrial paint booth systems at Nellis Air Force Base, Nevada. Specifically, the contractor must provide all labor, materials, equipment, and transportation to replace a total of 622 Virgin 4.0mm Coal Carbon filters across three specific locations: Building 252 Dock 1 (245 filters), Building 252 Dock 2 (167 filters), and Building 256 Dock 2 (210 filters). The performance period is estimated at six weeks, and the work is subject to FOB Destination terms. The award will be made on a Best Value Tradeoff basis, evaluating quotes based on the proposed Period of Performance start date and the Total Evaluated Price, provided the technical capability is rated as Acceptable and the price is determined to be fair and reasonable. Contractors are responsible for all safety and occupational health requirements, including providing personal protective equipment in compliance with OSHA, EPA, and Air Force safety instructions. While the contractor is responsible for the disposal of non-hazardous materials, the government end user will handle the disposal of hazardous materials. Offerors must submit quotes in PDF or Microsoft Office format to the designated contracting specialists. All contractor-owned equipment must be conspicuously labeled, and written approval from the Contracting Officer is required before bringing equipment into the work area.
Remediation Services

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
Federal
57 MXG Paint Booth Upgrade
Solicitation # FA486126R0021
This solicitation, identified as FA486126R0021, is a combined pre-solicitation and solicitation for a Firm Fixed Price contract under FAR Part 12, issued as a total small business set-aside for NAICS code 238220 with a size standard of $19 million. The procurement aims to upgrade paint booth environmental controls at Building 252 on Nellis Air Force Base, Nevada, with performance required to be completed within 210 calendar days after award receipt. Offerors must submit a complete Statement of Work detailing how requirements will be met, including full manufacturer, model, and part numbers for all proposed equipment. Evaluation will follow a Lowest Priced Technically Acceptable (LPTA) approach, where proposals must first achieve a rating of “Acceptable” on the Technical Capability factor before price is considered, with award going to the offeror with the lowest total evaluated price that is fair, reasonable, and not unbalanced. Site visits are mandatory for interested parties and must be scheduled by 31 July 2026, with attendees required to present valid identification and vehicle documentation to access the base. All questions must be submitted by 7 August 2026, with answers published by 14 August 2026, and proposals are due by 21 August 2026, delivered to the contracting office at Nellis AFB. Delivery is FOB destination, with the government responsible for acceptance at the designated location, and inspection will occur at both origin and final destination. All items must comply with MIL-STD-129 for packaging and marking and MIL-STD-130 for Unique Item Identification, requiring machine-readable Data Matrix codes with U.S. Department of Defense-compliant UII data elements. Contractors must comply with IUID reporting obligations through WAWF for all end items and embedded items over $5,000, and must flow down applicable clauses to subcontractors. Offerors must hold a valid UEI, be certified as small businesses, and adhere to restrictions on subcontracting limits—no more than 50% of services, 85% of supplies, or 75% of construction to non-similarly situated entities. Contractor personnel require base access credentials under AFI 31-101 and AFI 31-501, including vehicle registration and proof of insurance, and must maintain emergency contact
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

in 6 days
View Details
NAICS: 334220
New
Federal
Antenna Preventative Maintenance
Solicitation # F3G3FA6162AC02
The contract seeks a small business to provide comprehensive on-site Land Mobile Radio (LMR) Antenna Preventive Maintenance services at Nellis AFB and Creech AFB, Nevada, under a Firm Fixed Price (FFP) arrangement with a base year and four one-year option periods extending through August 2031. The scope requires the contractor to supply all personnel, tools, equipment, transportation, and certified labor to perform annual structural visual inspections and high-resolution sweep testing on tower-mounted antenna systems, connectors, and coaxial cabling, ensuring compliance with manufacturer specifications and a wide array of federal, military, and industry standards including Air Force Instructions, OSHA, NFPA, ANSI/TIA, UFC, and RUS Bulletins. The contractor must deliver detailed technical documentation of all test results, performance baselines, and system anomalies, maintain OEM price lists for all parts and materials, and adhere to strict reporting requirements including daily service tickets, annual FTE data, and observed defects reports within five business days of service. Labor invoicing must reflect a one-hour minimum with 30-minute increments, and all payments will be processed electronically through WAWF using the designated DoDAAC F87700. The contract is a 100 percent Small Business Set Aside under NAICS code 334220 with a size standard of 1,250 employees, and proposals must be submitted electronically as two separate PDF volumes—Volume I (price documentation limited to 25 pages) and Volume II (technical proposal also limited to 25 pages)—with pricing submitted in both PDF and editable Excel format. All proposals must be received by 1:00 PM PDT on August 6, 2026, addressed to both Addlene Williams and Samuel Toledo, with the solicitation number FA486126R0022 clearly indicated in the subject line. Technical acceptability is evaluated as a pass/fail gate based on subfactors including Quality Control Plan, Scheduling, and Equipment and Supplies, with failure in any subfactor resulting in an overall unacceptable rating. Award will follow a Lowest Price Technically Acceptable (LPTA) approach, with the lowest total evaluated price qualifying for award if the proposal meets all technical, responsibility, and regulatory requirements. The contract includes critical supplemental requirements such as compliance with DFARS 252.204-7012 and 252.204-7020
Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing

POSTED

2 days ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
Federal
26 WPS - WT15754265 - Mini Split Upgrade
Solicitation # FA486126Q0018
The contract requires the construction and installation of two maintenance pads to support all condensing units, using solid and vented concrete masonry units to ensure proper airflow, with screen block walls extended two rows above the units to match the existing CMU color and style. Each pad must include a weatherproof 120V maintenance receptacle, and the contractor must core drill Building 119’s wall to install a sealed 3-inch PVC pipe with acoustical seal for ICD 705 compliance. Insulation must be applied to all line sets entering the building, and all electrical wiring must originate from Room 119’s EDH 1 3 panel rated at 480/277V and 800 amps, with conduits surface-mounted indoors and run underground to each pad, each requiring a weatherproof disconnect. New cassette-type HVAC systems are to be installed in Rooms 112, 113, 114, and 132 using the existing ceiling grid with added support, supplying a 1-ton unit with a separate controller for Room 112, 2-ton units for Rooms 113 and 114, and a 4-ton unit for Room 132. All systems must be tied to the existing generator for backup power. The entire project must comply with the International Building Code, UFC standards, DOD directives, Nellis ID2 standards, and all applicable federal and Clark County codes, with the more stringent requirement taking precedence in case of conflict. Any discrepancies must be immediately reported to the Contracting Officer. The work must be completed within 160 days, and proposals will be selected based on lowest price, technically acceptable. A mandatory site visit is scheduled for August 4, 2026, at 0830 PDT at Building 119’s main entrance, and base pass requests for access to Nellis AFB must be submitted by July 24, 2026, at 2:00 PM PDT. Proposals are due by August 18, 2026, at 2:00 PM PDT, with questions addressed through solicitation amendments. This is a Small Business Set Aside under NAICS code 238220, managed by the Department of Defense at Nellis AFB, Nevada.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

in 5 days
View Details