Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

Supply of Thermo Fisher iBright CL750 Imaging System

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)View Agency

NAICS

334516 - Analytical Laboratory Instrument ManufacturingView NAICS

Place of Performance

Pittsburgh, PA, 15240

Set-Aside

NONE

Documents

This scope was carved out of 36C24426Q0852.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

6632--Thermo Fisher iBright CL750 Imaging Syst.

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Procurement and delivery of one Thermo Fisher iBright CL750 Imaging System, a commercial off-the-shelf laboratory instrument for protein and nucleic acid analysis.

Similar Contracts

Same NAICS industry code

NAICS: 334516
New
Federal
Spectrofluorometer (Fluorimeter) System Replacement
Solicitation # FA700026Q0056_A2
Solicitation FA700026Q0056_A2 is a combined type procurement issued by the Department of Defense, specifically the FA7000 10 Cons Lgc office at the USAF Academy in Colorado. The objective is the replacement of a Spectrofluorometer (Fluorimeter) System with a high-performance fluorescence spectrophotometer capable of measuring fluorescence, phosphorescence, chemiluminescence, and bioluminescence. The required system must feature a Xenon flash lamp, PMT detectors, integrated optical filters, and a wavelength range of 200 to 900 nm. Key technical performance benchmarks include a signal-to-noise ratio greater than 4,000:1, wavelength accuracy of plus or minus 0.5 nm, scanning speeds of at least 24,000 nm/min, and software-selectable bandwidths between 1.5 and 20 nm. The system must also support both liquid and solid sample analysis with Peltier and water-thermostatted temperature control and include a pre-loaded workstation for data acquisition and analysis. The procurement is an open market competition with no set-aside used, falling under NAICS code 334516. A critical contractual requirement is compliance with the Buy American Act per FAR 52.225-2, requiring offerors to provide a Buy American Certificate certifying the domestic origin of end products and critical components. Proposals are due by August 18, 2026. Evaluation is expected to be based on technical specifications including sensitivity, wavelength accuracy, scanning speeds, and warranty terms, although the specific basis of award and pricing details are not provided. Performance and final acceptance will take place at the USAF Academy in Colorado.
FA7000 10 Cons Lgc

POSTED

about 7 hours ago

DEADLINE

in 7 days
View Details

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 334516
New
Federal
6632--Thermo Fisher iBright CL750 Imaging Syst.
Solicitation # 36C24426Q0852
The U.S. Department of Veterans Affairs, through the Pittsburgh Contracting Office, is soliciting quotes for the Thermo Fisher iBright CL750 Imaging System under solicitation number 36C24426Q0852, issued as a brand-name-only requirement with single-source justification. Only authorized distributors of Thermo Fisher are eligible to respond, and all offerors must be currently registered in the System for Award Management (SAM) to receive an award. The procurement falls under NAICS code 334516 for Analytical Laboratory Instrument Manufacturing with a size standard of 1,000 employees and is classified under Product Service Code 6632 for Medical Laboratory Analysis Instruments. The system is needed to support VA Merit Award-approved research activities by providing direct in-lab imaging and analysis capabilities. The period of performance is 60 days after receipt of order, estimated to run from September 1, 2026, through October 31, 2026, with adjustments possible based on actual purchase order issuance date. Responses must be submitted by August 17, 2026, at 2:00 PM Eastern Time, following the specific instructions detailed in the solicitation documentation. The agency will issue any resulting award on Standard Form 1449, and the procurement is conducted on a full and open competitive basis, though limited to authorized Thermo Fisher distributors. The solicitation incorporates all applicable FAR provisions and VAAR clauses effective through FAC 2026-01, and full clause text is available via Acquisition.gov. The point of contact for inquiries is Contract Specialist Arlene Albrite, reachable at arlene.albrite@va.gov. All submissions must strictly adhere to the provided guidelines to be considered responsive.
Analytical Laboratory Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 334510
New
Federal
6515--Dry Eye Treatment System
Solicitation # 36C24426Q0860
The Department of Veterans Affairs, through the Coatesville VA Medical Center, is seeking a FDA-approved medical device for the treatment of dry eye syndrome and related ocular and dermal conditions including meibomian gland disease, blepharitis, acne rosacea, and skin conditions around the eyes. The required system must be a monopolar dual frequency radiofrequency device with electronic dynamic muscle stimulation, specifically designed for ophthalmic and optometric use, capable of safely treating patients of all skin tones without requiring anesthesia, numbing creams, injections, or eye drops. The device must feature zero post-procedure downtime, a touch screen interface, automatic treatment presets, and rounded electrodes contoured for eye safety and comfort, with the ability to tailor RF frequency depth and intensity based on individual skin thickness. The vendor is responsible for delivering, assembling, and installing the system on site at the Coatesville VAMC during normal business hours Monday through Friday 7:30 a.m. to 4:30 p.m., excluding federal holidays, and must coordinate scheduling at least seven business days in advance of shipment. Additionally, the vendor must provide comprehensive on-site training to staff and ensure the system is clean, free of scratches, and fully functional upon installation. The vendor is also required to remove all packaging debris, cartons, and trash from the facility and implement a recycling plan for the disposal of cardboard and other packaging materials. All proposals must be submitted by the deadline of August 14, 2026, at 6:00 a.m. Eastern Time, and are open to all responsible sources. The procuring office is the Department of Veterans Affairs Network Contracting Office 4 located in Pittsburgh, Pennsylvania, with Jefferson Mann serving as the primary point of contact for inquiries, reachable via email or phone. The solicitation number is 36C24426Q0860, and while the NAICS code is listed as 334510 for medical equipment manufacturing, no pricing details, contract value, evaluation criteria, or award methodology are specified in the documentation. No specific contract clauses, attachments, payment instructions, COR designation, or insurance requirements are provided, and while the device must meet strict technical specifications, acceptance standards and inspection procedures are limited to verifying the unit’s cleanliness and readiness for patient use.
Electromedical and Electrotherapeutic Apparatus Manufacturing

POSTED

1 day ago

DEADLINE

in 3 days
View Details