Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

Terminal Compression

Open
Z5496State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Nashville Electric Service has issued solicitation Z5496 for the procurement of terminal compression lugs. These tinned aluminum lugs must fit #2 and #1 aluminum or copper cables and be prefilled with a high voltage inhibitor, specifically ALNOX-UG-HV or an equivalent. Technical specifications require the lugs to be two-hole NEMA spaced for a 1/2 inch stud size and compatible for installation using a Kearney tool with a 5/8 die. The agency strictly prohibits alternate brands, accepting only products from HOMAC (SA2-NTN), PENN-UN (FKLA-C2-D TN), ASKINC (ALM212/1.75TP), or CONNECTO (ALM2ATP). Bidders must submit their proposals via the Bid Center by 2:00 pm local time on the close date of November 11, 2026. Evaluation for the award will be based on technical compliance and the earliest delivery timeframe stated in calendar days. For clarifications, vendors should contact Buyer II Bailey Allen.

General Info

Nashville Electric Service is procuring specific terminal compression lugs by November 11, 2026.

Documents

1
PDF, High priority: read this firstrfb
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyTennessee → Nashville Electric Service
Contacts1 person available
OfficeNashville, TN, USA
Office AddressNashville, TN, USA
Contacts
Bailey AllenProcurement Contact

Full Description

Show more
EA TERMINAL COMP 2-1 AL CU 2H COMPRESSION TINNED ALUMINUM LUG TO FIT #2 AND #1 ALUMINUM OR COPPER CABLE, PREFILLED WITH HIGH VOLTAGE INHIBITOR. TWO HOLE NEMA SPACED FOR 1/2" STUD SIZE. TO BE INSTALLED WITH A KEARNEY TOOL - #5/8 DIE. INHIBITOR TO BE ALNOX-UG-HV OR EQUAL. HOMACSA2-NTN PENN-UN FKLA-C2-D TN ASKINC ALM212/1.75TP CONNECTO ALM2ATP Stateyour earliest delivery IN CALENDAR DAYS: _ DELIVERY MAY BE CONSIDEREDIN THE AWARDOF THIS BID. _ Alternate brands will not be accepted on this inquiry. To have your product evaluated for future consideration, contact the buyerlisted in this RFB. _ In the eventof a discrepancy between the ordering description and part number, it is the responsibility of the vendor to contact the buyerfor clarification before the published CLOSE DATE. _ Note: This bid must be submitted usingthe Bid Center and must be received by 2:00 pm localtime on the published CLOSE DATE. _

Similar Contracts

Same NAICS industry code

More opportunities from Tennessee → Nashville Electric Service

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS