Transformer and Circuit Breaker Insulating Liquid Testing

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This subcontract for the Port Authority of NY & NJ involves performing sampling and laboratory testing of insulating liquids for prime contractors on PATH substation projects. The scope of work includes collecting oil samples from transformers and oil-filled breakers to analyze dielectric strength, moisture content, and dissolved gas analysis, with the final deliverable being detailed laboratory analysis reports on liquid quality. To qualify for this engagement, providers must hold laboratory certification for oil analysis and ensure personnel undergo S.W.A.C. background screening. The opportunity is categorized under NAICS code 541380, with a response deadline of October 7, 2026.

General Info

Subcontract for PATH substation oil sampling and testing; deadline October 7, 2026.

Documents

This scope was carved out of 6000003483.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Bid # 6000003483 -Electrical Equipment Inspecting, Cleaning, Calibrating, Testing and Repair Services to Equipment and Parts such as Protective Relays and Circuit Breakers, and Insulating Liquid Testing of Circuit Breakers and Transformers

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNew York → Port Authority Of Ny & Nj
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs sampling and laboratory testing of insulating liquids for prime contractors on Port Authority of NY & NJ (PATH) substation projects. Collects oil samples from transformers and oil-filled breakers for analysis of dielectric strength, moisture content, and dissolved gas analysis (DGA). Requires S.W.A.C. Background Screening and laboratory certification for oil analysis. Delivers laboratory analysis reports for liquid quality.

More opportunities from New York → Port Authority Of Ny & Nj

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS