Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from North Carolina was posted on February 6, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Ultrasonic Thickness Testing (UTT) for Pressure Vessels

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Onslow Water and Sewer Authority in North Carolina is seeking a subcontractor to perform ultrasonic thickness testing on ten pressure vessels. The primary objective of this project is to evaluate wall thickness, determine remaining service life, and assess corrosion levels in accordance with API 653 and API 510 standards. This opportunity was posted on February 6, 2025, and requires responses by March 7, 2025. The work falls under NAICS code 541380, focusing on specialized testing and inspection services to ensure the structural integrity of the designated equipment.

General Info

Subcontractor needed for ultrasonic thickness testing on ten pressure vessels by March 7.

Documents

This scope was carved out of 284.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

2025 Dixon WTP Pressure Vessel API Inspection RFP

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNorth Carolina → Onslow Water and Sewer Authority
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Conduct ultrasonic thickness testing at designated locations on ten pressure vessels to assess wall thickness, remaining life, and corrosion under API 653 and API 510 standards.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown