Ultrasonic Thickness Testing (UTT) of Cooling Water Pipe

Closed
FA254324SSBS05Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Aurora, CO, 80011, USA

Set-Aside

NONE

Documents

1

PWS for B430 Cooling Water Piping UTT

DOCX, High priority: read this firstsow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA2543 460 Cons
Contacts2 people available
OfficeBUCKLEY AFB, CO, 80011-9572, USA
Office AddressBUCKLEY AFB, CO, 80011-9572, USA

Full Description

Show more
This is an official Sources Sought. A requirement exists for a survey of Building 430, 433, and 435 Cooling Water Piping at Space Base Delta 2. Large amounts of metal rust flakes have been found lodged in Cooling Towers, Chillers, and Generators that support these buildings. This is indicative of pipe wall thinning brought on by heavy internal corrosion. The U.S. Air Force 460th Contracting Squadron at Buckley SFB, CO is posting this Sources Sought to find potential vendors capable of providing Ultrasonic Thickness Testing (UTT) for Cooling Water Pipes. The government is searching the market for contractors capable of providing Ultrasonic Thickness Testing (UTT) in a timely manner. This must be done without shutting off the water. What certifications are required for a contractor to conduct UTT? how long does UTT take? What are the risks? Are there other, less risky forms of testing the pipes? Has the government overlooked anything for this requirement in the attached DRAFT Performance Work Statement (PWS)? Responses are to be sent via email to Contract Specialist (CS), A1C Guillermo Torres at contact@example.gov and Contracting Officer (CO) TSgt Brittainy Shirley at contact@example.gov NLT 10 AM MDT, 17 June 2024. Please include the Sources Sought Identification Number or title in the subject line of the email submission. SUBMISSION DETAILS: Please include questions, concerns, considerations for this testing Questions seeking clarification that expect responses are due by 13 June 2024 We would greatly appreciate that all responses include a projected quote Please include the following information in your response: - Company name, address, and point of contact, with email address and phone number - CAGE Code and/or Unique Entity Identification (UEID) number

More opportunities from Department Of Defense → FA2543 460 Cons

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS