University of Alberta - Request for Proposal - UNIVERSITY OF ALBERTA COOLING PLANT (CPOC) CONDENSER WATER CHEMICAL TREATMENT PROGRAM

Active
AB-2026-06731International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The University of Alberta is seeking proposals for the design and implementation of a chemical treatment program for the condenser water system at the Cooling Plant On Campus in Edmonton. The system consists of five 2000 ton high pressure centrifugal chillers and five cooling towers connected via a common header system, managing a total volume of 95 cubic meters. The program must account for operating temperatures ranging from 13 to 40 degrees Celsius and a flow rate of 1330 cubic meters per hour per chiller and cooling tower. This solicitation, identified as AB-2026-06731, requires responses by November 3, 2026. The university intends to establish an initial two year contract with the possibility of two four year extensions, allowing for a total potential contract duration of ten years. The selected provider will support a critical component of the North Campus chilled water distribution network, which serves over 80 buildings.

General Info

University of Alberta seeks chemical treatment for cooling plant condenser water system.

Place of Performance

Edmonton, AB, CAN

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyUniversity of Alberta
Contacts1 person available
OfficeN/A
Organization / AgencyUniversity of Alberta
Office AddressN/A
Contacts
Shauna WilliamsProcurement Specialist

Full Description

Show more
The University of Alberta (University), located in Edmonton, Alberta, is the largest post-secondary institution in the province, with a total enrolment of approximately 46,000 undergraduate and graduate students, and a workforce of approximately 12,000 academic and support staff. Our University has a proud legacy of high-impact research and creativity across a wide range of disciplines. The University is driven by a commitment to support innovation in teaching, discovery, and community service. Its enduring vision is to be one of the world’s great universities for the public good, in line with the founding promise that "the uplifting of the whole people shall be its final goal." The University of Alberta is inviting the submission of Proposals for the design and implementation of a chemical treatment program for the chiller condenser water system for Utilities, Cooling Plant On Campus (CPOC). CPOC has five 2000 ton high pressure centrifugal R134A chillers that supply chilled water to the UofA North Campus. This plant uses five cooling towers to extract the heat from the chiller condensers. The UofA is exploring options for a water treatment system for the 95 m3 (25,000 US Gallons) CPOC condenser water system. The operating temperature of the condenser water system will not fall below a minimum temperature of 13.0C and the maximum temperature is determined by the outside ambient air temperature which can reach upwards of 40°C. The plant flow rate for one chiller is 1330.00 cubic meters per hour. Each cooling tower is also set at a rate of 1330 m3/hr. One unique feature of the CPOC plant is that the cooling towers and chillers are all connected together through a common header system instead of the typical configuration of one cooling tower directly connected to one chiller. The campus chilled water distribution system consists of a main chilled water plant (26000 tons) that operates year round, a Thermal Energy Storage System (approximately 5000 tons), and the CPOC plant (10000 tons) which are connected to over 80 buildings on the UofA North Campus via piping running through 11 kms of corridor. Our intention is to have an initial two (2) year contract with option to renew for an additional two (2) four (4) year extensions for a total contract length of ten (10) years.

Similar Contracts

Same NAICS industry code

More opportunities from University of Alberta

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS