Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on March 14, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Upgrade Central Chiller Plant and DDC Controls

Closed
W912PL24B0004Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a subcontracting opportunity to perform multi-building plumbing leak repairs at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Rooms 123 and 213, repairing a cracked drain pipe in the pipe chase of Room 216, and replacing approximately ten linear feet of leaking heat pipe sections in both the Administration Building and King Hall. All work must conform to the Massachusetts State Plumbing Code and International Plumbing Code, utilizing new commercial-quality materials suitable for hydronic heating service. The contractor is responsible for removing all debris and repairing any facility damage caused during performance at no additional cost. Interested bidders must submit a detailed quote by October 30, 2026, including a comprehensive cost breakdown of labor and materials, a proposed service schedule, and a bid validity period of at least 60 days. Required documentation includes a current SAM.gov UEI number, active registration, Massachusetts licensing, a W-9, a signed ETR Vendor Acknowledgement Form, and certificates of insurance. This is an SBA set-aside opportunity for various small business categories. Award selection is not based solely on the lowest price; ETR will evaluate cost, qualifications, and administrative compliance. The project is subject to federal regulations, including the Davis-Bacon Act, Service Contract Act, and specific FAR clauses regarding anti-lobbying and debarment. Performance bonds are required for projects exceeding 35,000 dollars.
Westover Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in 9 days
NAICS: 238220
New
MI 2026-14 Emergency Heating and Air Conditioning Services
Solicitation # MI 2026-14
Adams and Associates, Inc., contracting for the U.S. Department of Labor, is soliciting bids for emergency heating and air conditioning services at the Miami Job Corps Center in Florida. The period of performance runs from November 1, 2026, to October 31, 2027. The selected vendor will provide emergency HVAC repairs, with pricing required for non-emergency daytime services (8:00 am to 4:30 pm) as well as emergency, weekend, and holiday rates. As a federally funded facility, the Center is entitled to GSA pricing. Award decisions will be based on the most responsible bidder, considering cost, licensure, experience, and insurance capabilities. Eligible bidders must be small businesses or certified socioeconomic categories, including VOSB, SDVOSB, WOSB, and HUBZone. Mandatory requirements include a valid Unique Entity ID (UEI), active SAM.gov registration, and all necessary Florida state business and employee licenses. Vendors must maintain Workers Compensation, Automobile Liability, and Comprehensive General Liability insurance of at least $1,000,000 per occurrence. The contract is subject to the Service Contract Act (Wage Determination No. 2005-2248) and the Davis-Bacon Act, with a minimum wage of $13.65 per hour applicable through December 31, 2026. Bids must be submitted on company letterhead by October 23, 2026, and include a W9, Vendor Questionnaire, Authority to Commit, and a certificate of insurance. Payment terms are NET 30 days. Personnel performing work on-site must adhere to strict security protocols, including searches and a prohibition on fraternization with students and staff. All deliveries must be coordinated through the Center's security personnel.
Miami Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in 2 days
NAICS: 238220
New
CBP6585 Bldg. 22 HVAC Replacement
Solicitation # CBP6585
Management & Training Corporation (MTC) is seeking bids for a fixed-price, single lump sum subcontract to replace the HVAC equipment serving Building 22 at the San Diego Job Corps Center in Imperial Beach, California. The scope of work includes the removal of existing equipment and the installation of a new 5-ton condenser with a suitable pad, a new furnace, a 5-ton evaporator coil, a fused electrical disconnect, an electrical whip, and a new condensate drain line. The contractor is responsible for providing all labor, materials, and supervision, ensuring the system is fully operational and compliant with applicable codes. Key deliverables include two sets of operation and maintenance manuals and manufacturer and installer warranties. The estimated price range for this project is between 0 and 25,000 dollars. Bids are due by October 28, 2026, and must be submitted using the MTC Bid for Lump Sum Contract form, accompanied by a detailed cost breakout, proof of insurance, and three references. A physical site visit and signature on the attendance roster are mandatory prerequisites for bid submission. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent of the base bid is required, and the awarded contractor must provide performance and payment bonds for 100 percent of the contract price from a surety with at least an A- rating. This opportunity is set aside for small businesses under NAICS 238220. Award decisions will be based on overall best value. Compliance requirements include the Davis-Bacon Act for prevailing wages, OSHA safety standards for personal protective equipment, and various Federal Acquisition Regulations, including those regarding first-tier subcontractor information and the submission of form SF 1413. Awarded contractors must provide a Unique Entity ID (UEI) number and complete the MTC Supplier Self-Certification packet. Payment will be made via progress payments based on percentage completion, utilizing AIA Document G702 and G703 or equivalent forms.
San Diego Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in 8 days
NAICS: 238220
New
MJCC EXHAUST FANS BLD. 1429
Solicitation # mjcc-exhaust-fans-bld-1429
The Muhlenberg Job Corps Center, operated by Insights Training Group LLC, is soliciting fixed-price quotes from qualified HVAC and mechanical contractors to restore the exhaust fan and louver systems in Building 1429 located in Kentucky. The scope of work includes the inspection, repair, and replacement of various components across eight exhaust fans, specifically addressing failed louver actuators, motor replacements, selector switch repairs, and the relocation of a thermostat. Contractors must provide detailed line-item pricing for each fan, separate pricing for system-wide component replacements, and detailed costs for labor and materials. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Award will be granted to a single responsible offeror based on technical acceptability and the lowest price. Key requirements include compliance with the Federal Acquisition Regulation, Davis-Bacon Act labor standards, and OSHA and EPA regulations. Contractors must be registered and licensed in the State of Kentucky, provide proof of insurance, and demonstrate the ability to secure performance and payment bonding. Administrative requirements include the submission of weekly certified payroll with every invoice and the provision of Materials Safety Data Sheets for all products used on site. The project involves a substantial completion process requiring a walk-through and final acceptance inspection. Quotes must be submitted electronically to the purchasing agent by October 30, 2026, and must include a completed New Vendor Profile and W-9 for any subcontractors.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 9 hours ago

DEADLINE

in 9 days
NAICS: 238220
New
Furnace Replacement
Solicitation # 26-17
Management & Training Corporation (MTC), operator of the Tongue Point Job Corps Center in Astoria, Oregon, is soliciting bids for a fixed-price, lump sum contract to replace furnaces and thermostats in three staff houses. The project involves Quarters F (3,786 sq/ft, propane), Quarters P (1,100 sq/ft, natural gas), and Quarters Q (2,280 sq/ft, propane). Required equipment must be Carrier Comfort Series or an equivalent household good grade with at least a 96% efficiency rating, sized at approximately 80,000btu. Installations must include new transitions to existing ducting, gas regulators, electrical and condensate pump kits, and intake/exhaust venting. A lifetime warranty on the heat exchanger and a minimum 10-year warranty on parts are mandatory. The estimated price range for this solicitation is between $0 and $25,000, with bids due by October 21, 2026. This is a small business set-aside opportunity under NAICS code 238220. Award decisions will be based on overall best value. Contractors must comply with the Davis-Bacon Act and applicable prevailing wage determinations, providing certified payroll weekly. Bid and performance bonds are only required for bids equal to or exceeding $25,000. Submission requirements include a signed MTC bid form, a detailed cost breakout on company letterhead, a Unique Entity Identification number, and a completed supplier self-certification packet. Final acceptance is contingent upon functional testing, the submission of operation and maintenance manuals, and a final inspection.
Tongue Point Job Corps

POSTED

about 9 hours ago

DEADLINE

in about 20 hours
NAICS: 238220
New
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum subcontract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project scope involves the demolition and removal of the existing dry system distribution piping network and failing air compressor across the Men's Dormitory (Building CM), Women's Dormitory (Building CW), and Recreation Building (Building D). The selected licensed fire sprinkler contractor must eliminate system leaks and install a new compressor sized according to NFPA standards to prevent equipment short-cycling. All work must adhere to NFPA 25 (2023 Edition) and local, state, and national codes, with a required performance period of 30 consecutive business days following the Notice to Proceed. Bids are due by December 1, 2026, and must be based on a mandatory site visit. Evaluation is based on overall best value and bidder responsiveness. For bids totaling $25,000 or more, a bid bond of 20% of the base bid is required at submission, and the awarded contractor must provide performance and payment bonds from an A-rated surety within five business days of the Intent to Award. Compliance requirements include adhering to Davis-Bacon prevailing wage rates for Idaho, submitting weekly certified payroll reports, and providing a 12-digit UEI number. Additionally, first-tier subcontractors with awards exceeding $45,000 must disclose debarment status per FAR 52.209-6, and contracts valued at $40,000 or more are subject to FFATA reporting.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in about 1 month
NAICS: 238220
New
MJCC HVAC BLD. 1403-04 B HALL
Solicitation # mjcc-hvac-bld-1403-04-b-hall
Insights Training Group LLC, on behalf of the Muhlenberg Job Corps Center, is soliciting fixed-price quotes for an HVAC project at Building 1403-04 B Hall in Kentucky. The scope of work requires the contractor to furnish and install two 4-ton Trane split systems with a minimum 17 SEER rating, two 95% AFUE high-efficiency gas furnaces, and matching indoor evaporator coils using R-454B refrigerant. Additional requirements include the installation of a Honeywell Pro 8000 programmable thermostat, new refrigerant line sets, condensate drain piping, and pumps. The project must be completed within 45 days of award, and the contractor is responsible for all inspections, testing, and providing necessary operating and maintenance manuals. The contract will be awarded to the responsible offeror who is technically acceptable and provides the lowest price. To be considered, bidders must be registered and licensed in the State of Kentucky, verified through the SAM portal, and provide a minimum 90-day bid guarantee along with proof of ability to secure performance and payment bonding. Compliance with the Davis-Bacon Act and Certified Payroll Wage Rate requirements is mandatory, with weekly certified payroll and a signed Statement of Compliance required for invoice acceptance. All work must adhere to local codes, manufacturer specifications, OSHA, and EPA regulations. Quotes are due by October 30, 2026, and must include detailed labor and materials costs, a W-9, and a New Vendor Profile.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 9 hours ago

DEADLINE

in 9 days
NAICS: 238220
New
Roswell JCC – Male Dormitory Bldg. Water Source Heat Pump Replacement (20 units)
Solicitation # roswell-jcc-male-dormitory-bldg-water-source-heat-pump-replacement-20-units
Career Systems Development Corporation is soliciting proposals for the total replacement of twenty ceiling-mounted water source heat pumps at the Roswell Job Corps Center Male Dormitory Building 558 in New Mexico. The scope of work includes the removal and off-site disposal of twenty failed units and the installation of new Bosch 1-ton units or equivalent, including all necessary ducting, electrical, gas, thermostat wiring, flexible hoses, and pressure valves. Additionally, the contractor must install smoke dampers with fusible links in all vents leading into the plenum and ensure all materials used in the plenum are plenum-rated. All work must comply with NFPA 101, NFPA 70, and applicable plumbing, mechanical, and building codes, with performance scheduled between 7:00 am and 4:00 pm, Monday through Friday. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified firms. The project is subject to the Davis Bacon Act Wage Determination NM20260014, requiring the submission and approval of weekly certified payroll reports prior to invoice payment. Proposals exceeding $100,000.00 require payment and performance bonding for 100% of the contract value. Submissions must include a safe work process, detailed costs for labor and materials, equipment cut sheets, warranty information, and a requested payment schedule. Final deliverables include the provision of operation manuals to the Facility Manager upon project completion.
Career Systems Development Corporation

POSTED

about 9 hours ago

DEADLINE

in 17 days

General Info

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

Long Beach, CA, 90822, USA

Set-Aside

SDVOSBC

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

special-notice

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W075 Endist Los Angeles
Contacts2 people available
OfficeLOS ANGELES, CA, 90017-3409, USA
Office AddressLOS ANGELES, CA, 90017-3409, USA

Full Description

Show more
This project intends to replace the existing Chillers, Upgrade/Refurbish Existing Cooling Towers, Upgrade/Replace the Primary and Secondary Chilled Water Pumps, Condenser Water Pumps, related Piping and Controls, pressure differential Delta P valves in main chilled water lines entering each of the buildings, and interface with existing Johnson Controls Metasys System. The intent of this announcement is to specify brand-name equipment to be included in the design. The notice of intent will cover only the portion of the acquisition that is the brand name or peculiar to one manufacturer. Use of such descriptions in the design is essential to the Government's requirements to ensure system compatibility, warranty, and/or training, thereby precluding consideration of a product manufactured by another company. A brief description of each system is listed below. Energy Management Control System. - The government requires use of Johnson Controls Inc, Metasys Building Automation and Control Systems (Metasys System). This system is the overall system used to control the Heating and Ventilation and Air Conditioning (HVAC) systems in the main hospital building (Building 126) and all surrounding buildings Door Hardware System. - The government requires the use of Schlage Primus Large Format IC (Interchangeable core locks) for security and inventory purposes. The door hardware system needs to remain uniform and in compliance with the existing key system Security Access System. - The government requires use of Identiv Hirsch Security Access Control Equipment and Identiv Velocity Video Management System security related monitoring systems as they are already deployed throughout the VALBHS campus. Life Safety System. The government requires use of Edwards EST3, Addressable Fire Alarm System. This system is the Medical Center's standard for fire alarm systems security related monitoring systems in the main hospital building (Building 126) and all surrounding buildings. Life Safety System. The government requires use of Novec 1230 Extinguishing System. This system is the Medical Center's standard for fire extinguishing systems and already deployed throughout the VALBHS campus. The following are the essential items requiring the brand name requirements: a) System Compatibility A non-integrated system comprised of incompatible parts will result in unacceptable delays in fulfilling the VALBHS campus requirements. To maintain proper operations and warranties, the parts used in servicing the equipment should only use approved parts from the manufacturer. A fully integrated system designed to operate and work together optimizes performance. Components from different manufacturers are not always compatible with each other which can lead to challenges during installation and integration. Incompatibilities may result in improper connections, communication failures, or unreliable performance. b) Warranty It is typical for the work performed on the noted equipment to require a manufacturer certified technician to provide and maintain current warranties. The installation of non-manufacturer parts and the consequent need for certified technicians from multiple manufacturers will result in unacceptable delays and the duplication of maintenance contract costs in fulfilling VALBHS campus requirements. c) Training. The use of non-manufacturer parts which are not consistent with the current systems would result in substantial duplication of training costs due to the requirement for equipment manufacturer specific training that addresses the proprietary features and needs of operating and maintaining the systems. An integrated system and standardization of equipment will prevent this additional financial burden. The information identified above is intended to be descriptive of why it is imperative the Brand Name Only equipment and controls are to be used. Responses to this announcement should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 238220. Please answer the following questions: Provide an alternative to using mentioned equipment, with supporting rationale, that would alleviate the Government's concerns regarding system compatibility. Provide an alternative to using mentioned equipment, with supporting rationale, that would alleviate the Government's concerns regarding warranties. Provide an alternative to using mentioned equipment, with supporting rationale, that would alleviate the Government's concerns regarding duplication of training costs. Provide rationale as to how a on non-integrated equipment system will result in a more reliable system (than an integrated system using only aforementioned equipment) to ensure that compatibility and standardization efforts are not impacted. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Special Notice. Information will only be accepted in writing by e-mail to Contract Specialist Ashley Powell at ashley.s.powell@usace.army.mil and James Costantino at james.m.costantino@usace.army.mil.

More opportunities from Department Of Defense → W075 Endist Los Angeles

Same awarding agency

NAICS: 531120
New
Federal
Retail Space for Lease in Los Angeles
Solicitation # DACA095270087900
The U.S. Army Corps of Engineers, Los Angeles District, is soliciting proposals for a full-service lease of Class A or B retail space to establish an Armed Forces Career Center in Los Angeles, California. The required space must be between 868 and 1,151 square feet and be located within a specific delineated area bounded by Weyburn Avenue to the north, Wilshire Boulevard to the south, Westwood Boulevard to the east, and Veteran Avenue to the west. The lease term is not to exceed five years and must include government termination rights. The facility must be located in a compatible business area, away from sexually oriented businesses, bars, or dispensaries, and must be accessible via mass transit within three walking blocks. Key requirements include a primary and secondary point of ingress/egress, 24/7 lighted parking for four government vehicles, and additional parking for employees and visitors. The lessor is responsible for a turnkey build-out conforming to construction and security specifications, including ADA/ABAAS compliance and seismic standards. Award will be based on the most advantageous offer, balancing price—including rent, utilities, and janitorial services—with technical factors such as neighborhood quality, ease of access, and building appearance. Proposals are due by 5:00 PM Pacific Time on October 27, 2026, and must include a signed Proposal to Lease Space form, as-built floor plans, and a completed seismic offer form.
Lessors of Nonresidential Buildings (except Miniwarehouses)

POSTED

about 13 hours ago

DEADLINE

in 7 days
View Details
NAICS: 237310
New
Federal
Repair Storm Damage Imperial Dam Road at YPG, AZ
Solicitation # W912PL26S0058
The U.S. Army Corps of Engineers, Los Angeles District, is issuing a sources sought notice for a future FY27 firm-fixed price design-build construction contract to repair storm damage on Imperial Dam Road at the Yuma Proving Ground in Arizona. The project involves reconstructing approximately 4,505 feet of roadway, raising the grade, installing culverts, and regrading wash areas and ditches to improve stormwater runoff. Additional requirements include replacing signs and installing reflective pavement markings in accordance with ADOT, MUTCD, and SDDCTEA standards. The estimated project value is between 4 million and 7 million dollars with a performance period of 600 calendar days. This notice is for preliminary planning and market research to identify qualified sources under NAICS code 237310. Interested parties, including various small business classifications and other than small businesses, must submit their qualifications, bonding capacity, and examples of similar past performance by October 21, 2026. Specifically, firms must demonstrate experience with road reconstruction projects of similar magnitude, including at least one project valued over 2 million dollars completed within the last six years. This is a request for information only and does not constitute a request for proposals or a commitment to award a contract.
Highway, Street, and Bridge Construction

POSTED

7 days ago

DEADLINE

in about 20 hours
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award