Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Defense was posted on July 21, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Upgrade the Emergency Power System at Building 104

Closed
FA282322R0014Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236220
New
Construction of the Recharge Master Plan Update Basin Improvements Project Montclair Basin Improvements
Solicitation # construction-recharge-master-plan-update-basin-improvements-project-montclair-basin-improvements-2
The Construction of the Recharge Master Plan Update Basin Improvements Project Montclair Basin Improvements is a solicitation issued by RT Contractor Corp for the Inland Empire Utilities Agency. This project, located in California with a specific performance area in Riverside or Los Angeles, focuses on basin improvements under NAICS code 236220. The solicitation was posted on October 19, 2026, with a response deadline of November 4, 2026. This opportunity is specifically set aside for Disadvantaged Business Enterprises (DBE) as defined by the Department of Transportation. To secure project financing, the Inland Empire Utilities Agency requires strict adherence to expanded DBE Good Faith Effort (GFE) guidelines. Bidders must provide proof of utilizing SBA and MBDA services and demonstrate that solicitations were posted in an online publication for 30 consecutive days and in a newspaper for at least one day prior to the bid opening. Failure to include this documentation within the bid package will result in the proposal being deemed non-responsive. While outreach documentation may be submitted up to three business days after the closing date, all other mandatory GFE requirements must be met by the opening date to ensure compliance.
RT CONTRACTOR CORP

POSTED

about 2 hours ago

DEADLINE

in 15 days
NAICS: 236220
New
P084 NEXT GENERATION TORPEDO INTEGRATION LAB & P1016 Consolidated RDT&E Systems Facility – Newport, RI
Solicitation # p084-next-generation-torpedo-integration-lab-p1016-consolidated-rdte-systems-facility-newport-ri
J&J Contractors, Inc. is soliciting bids for the construction of the Next Generation Torpedo Integration Lab and the P1016 Consolidated RDT&E Systems Facility in Newport, Rhode Island. The project involves the development of a 12,920 square foot multi-story steel frame laboratory and office facility, as well as an optional 17,978 square foot laboratory facility. Construction features include shallow foundations, metal standing seam roofs, and exterior walls composed of masonry and metal panels. The scope of work encompasses comprehensive site preparations, including landscaping, parking, exterior lighting, and the installation of underground stormwater retention and utility systems. Additionally, the project requires the demolition of Building 1272T, a 548 square meter engineering facility. Pricing is requested across a wide array of trades, including demolition, abatement, concrete, masonry, structural and miscellaneous metals, millwork, roofing, drywall, flooring, painting, elevator installation, fire protection, plumbing, mechanical, electrical, sitework, and crane services. This is a small business set-aside solicitation subject to Davis Bacon Wage Rates and is exempt from sales tax. Interested parties must contact the primary point of contact to receive bid invitations and documents via Building Connected. The response deadline for this solicitation is November 30, 2026.
J&J CONTRACTORS, INC.

POSTED

about 2 hours ago

DEADLINE

in about 1 month
NAICS: 236220
New
CITY OF GREENFIELD WASTEWATER TREATMENT PLANT UPGRADE PROJECT
Solicitation # city-greenfield-wastewater-treatment-plant-upgrade-project
The City of Greenfield Wastewater Treatment Plant Upgrade Project involves the construction of a new 2.0 million gallons per day facility located on the northeast end of Walnut Avenue in Greenfield, California. The project scope is divided into four distinct phases: site preparation involving soil stabilization and utility relocation; construction of the plant including a packaged Membrane Bioreactor treatment plant, headworks, UV disinfection, and SCADA systems; decommissioning and demolition of existing facilities; and the completion of finish facilities including the Walnut Avenue extension. The total duration for the project is 915 calendar days, with a critical requirement to maintain existing plant services and regulatory compliance throughout the first two phases. Managed by C. Overaa & Co., the solicitation is open to various small and disadvantaged business enterprises, including DBE, SDVOSB, and WOSB. A significant local hiring goal requires that 50 percent of the total construction workforce be residents of Monterey, San Benito, or Santa Cruz counties. Subcontractors must utilize the Textura electronic system for invoicing and payments and are required to accept the standard Overaa agreement without modification. Key milestones include a mandatory pre-bid meeting on October 5, 2026, with bid submission deadlines listed as either October 28 or November 10, 2026.
C. Overaa & Co.

POSTED

about 2 hours ago

DEADLINE

in 21 days
NAICS: 236220
New
P1102 Weapons Magazine and Ordnance Operations Facility, Naval Submarine Base New London, Groton, Connecticut
Solicitation # p1102-weapons-magazine-ordnance-operations-facility-naval-submarine-base-new-london-groton
This solicitation issued by J & J Contractors, Inc. seeks pricing for the P1102 Weapons Magazine and Ordnance Operations Facility project at the Naval Submarine Base New London in Groton, Connecticut. The project has a duration of 1828 calendar days and involves the construction of six Containerized Long Weapons Storage units, two Box G magazines, and one Box H earth-covered high-explosive magazine. The scope includes comprehensive site work such as clearing, rock excavation, grading, and wetland mitigation, as well as the construction of an Ordnance Operations building, a Truck Inspection area, and a Sentry building. Demolition of 18 existing magazines and buildings 524 and 393 is also required. Technical requirements encompass a wide range of trades including demolition, abatement, concrete, structural steel, roofing, electrical, plumbing, and mechanical systems. Specialized construction features include rigid inclusions, load transfer mats, grounding and lightning protection, and intrusion detection systems. The project also involves installing primary and secondary electrical distribution, telecommunications infrastructure, access roads, and landscaping. This opportunity is set aside for various small business categories, and interested parties must contact the primary point of contact by the October 31, 2026, deadline to receive bid documents.
J & J Contractors, Inc

POSTED

about 2 hours ago

DEADLINE

in 11 days

General Info

NAICS

236220 - Commercial and Institutional Building Construction

Place of Performance

Eglin AFB, FL, 32542, USA

Set-Aside

SBA

Documents

26

50 Division Cost Estimate Worksheet - Eglin Air Force Base

XLS, High priority: read this first96 pages · specifications
High

Building 104 As-Builts - First Floor Electrical Plan (FTFA 13-1087)

PDF, High priority: read this first1 page · specifications
High

FA282322R00140001 Amendment 0001

PDF, High priority: read this first2 pages · amendment
High

FA282322R00140002 Amendment

PDF, High priority: read this first2 pages · amendment
High

FA282322-R0014 Past Performance Questionnaire

PDF, High priority: read this first3 pages · past-performance
High

FA282322R0014 - Upgrade Emergency Power System Bldg 104

PDF, High priority: read this first42 pages · rfp
High

FA2823-22-R-001 Attachment L4 - Past Performance Consent Letter

PDF, High priority: read this first1 page · past-performance
High

FTFA 21-VP05 Section L - Instructions to Offerors

PDF, High priority: read this first12 pages · rfp
High

FTFA 21-VP05 Section L - Instructions to Offerors

PDF, High priority: read this first12 pages · rfp
High

FTFA 21 VP05 Section M - Evaluation Factors for Award

PDF, High priority: read this first5 pages · rfp
High

FTFA 21 VP05 Section M - Evaluation Factors for Award (Bldg 104 Emergency Power System)

PDF, High priority: read this first5 pages · evaluation-factors
High

FTFA 21-VP05: Upgrade Emergency Power System Bldg 104

PDF, High priority: read this first16 pages · sow
High

Fuels Compliance, Distro, and Support - Bldg 89

PDF, High priority: read this first1 page · specifications
High

FA2823-22-R-0014 Attachment L2 - Financial Responsibility Questionnaire

PDF, Low prioritypast-performance
Low

FA2823-22-R-0014 Past Performance Cover Letter

PDF, Low priority1 page · past-performance
Low

FA282322R0014 - Upgrade Emergency Power System B104 Q&A

PDF, Low priority4 pages · q-and-a
Low

041858_E2.pdf

PDF

041858_E4.pdf

PDF

A0290026.pdf

PDF

A0290028.pdf

PDF

a0290073.pdf

PDF

a0290076.pdf

PDF

A0290157.pdf

PDF

A0290161.pdf

PDF

A0290162.pdf

PDF

Bldg+104+Sign+in+Sheet.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA2823 Aftc Pzio
Contacts1 person available
OfficeEGLIN AFB, FL, 32542-5418, USA
Office AddressEGLIN AFB, FL, 32542-5418, USA

Full Description

Show more
Eglin Air Force Base (AFB), FL has a requirement to provide all design and construction effort required to upgrade the Building 104, Eglin Radar Control Facility Emergency Power System on Eglin AFB, FL. The North American Industry Classification System (NAICS) code for this requirement is 236220 Commercial and Institutional Building Construction Contractors with a size standard of $39.5M. Statement of Magnitude is between $1,000,000 and $5,000,000. This is a Small Business Set-Aside competitive acquisition utilizing a best value source selection process and award will be made based upon the Best Value to the Government in accordance with FAR Part 15.3. This project includes, but is not limited to, the following: provide a new Emergency Power System that shall consolidate all mission critical electrical loads on one emergency generator and one automatic transfer switch (ATS). Replace 277/480 V, 800 A main distribution electrical panel MDP with new panel. Remove panel PC and transfer its circuits to new panel MDP. Remove 150 KVA and 225 KVA transformer banks, and replace with a new 480 V primary, 120/208 V secondary dry-type transformer (sized as required) fed from new panel MDP. Remove the 400 A safety switch feeding ATS #1, remove the 400 A technical ATS #1, and the 600 A mechanical ATS #2. Then, install a new 120/208 V, 4-pole, Bypass Isolation, and Closed Transition ATS (sized as required) fed from the new dry-type transformer referenced above. Install a new 120/208 V circuit breaker sized as required to feed the new ATS referenced above. Remove the existing 175 KW and 100 KW emergency generators and install a new 120/208 V emergency generator (sized as required) in the existing generator room'if possible. Remove the existing underground diesel fuel storage tank and fuel piping. Install a new 1,000 gallon above ground storage tank and fuel piping connected to new generator. Remove the two 25-gallon generator day tanks in the existing generator room. Install a new 120/208 V emergency distribution panel DPE (sized as required) fed by a new ATS. Replace the existing 120/208 VAC, 600 A (MLO) electrical panel DPME and 120/208 VAC, 400 A (MLO) electrical panel DPTE with new panels fed from the new panel DPE. Remove the panel LA and transfer its circuits to the new panel DPME. Transfer the lighting circuit/s for mechanical room to the new panel DPME. Also, remove associated wiring and conduit not required by any existing electrical systems not being removed by this project. The project shall comply with applicable DOD, Air Force, and base design rules and standards. 28 June 2022 - Formal Release of Amendment 001 The purpose of Amendment 001 is: 1. Update Section 1.5.5 Recency Assessment and table M2 Relevancy Ratings in Section M. 2. Update the date in Section 1.9 Questions and Answers Period in Section L. 3. All updates are highlighted. The purpose of Amendment 002 is: 1. Post RFI questions and answers. 2. Post the site visit sign in sheet. 3. Post As-Builts for Bldg 104. 4. Post revised 50 Division Worksheet.

More opportunities from Department Of Defense → FA2823 Aftc Pzio

Same awarding agency

NAICS: 334310
New
Federal
Conference Room Remodel
Solicitation # FA2823-26-Q-A113
Solicitation FA2823-26-Q-A113 is a firm-fixed-price request for quote issued by the Air Force Test Center for the modernization of the audiovisual system in Building 104, Room 101 at Eglin Air Force Base, Florida. This project is a total set-aside for small businesses under NAICS 334310. The scope of work includes the complete decommissioning of legacy equipment and the installation of a Trade Agreements Act compliant AV-over-IP distribution system, high-definition displays, digital audio processing, PTZ cameras, and an integrated conference table. The resulting system will be designated for unclassified use and must support hybrid collaboration and local presentations without connecting to the government network. The government will award the contract based on best value, evaluating technical capability, past performance, and price. Offerors must submit their proposals in three separate volumes—Technical Capability, Past Performance, and Price—contained within a single PDF. Key requirements include a delivery schedule of no later than 120 days after receipt of order and the provision of an on-site commercial dumpster for waste disposal. All equipment must be TAA-compliant, and high-value items costing $5,000 or more require unique item identification per MIL-STD-130. The current proposal submission deadline is October 21, 2026, at 1:00 PM EDT.
Audio and Video Equipment Manufacturing

POSTED

about 20 hours ago

DEADLINE

in 6 days
View Details
NAICS: 811121
Federal
FIRE APPARATUS INTERCOM SYSTEM UPLIFT AND INSTALLATION
Solicitation # FA282326Q0065
The Air Force Test Center, Operational Contracting Division at Eglin Air Force Base, Florida, is soliciting quotations for RFQ FA282326Q0065 to procure and install new 4-position onboard intercom systems for twelve fire apparatuses, including ten fire engines, one ladder truck, and one rescue vehicle. This firm-fixed-price contract requires the removal of legacy components and the installation of systems integrated with Motorola APX 6500 mobile radios, featuring wireless driver headsets with a minimum connectivity range of 500 feet. All work must be performed on-site at Fire Station 1 and comply with NFPA 1901 automotive and emergency vehicle wiring standards. The period of performance is 90 calendar days after award, with delivery terms set as FOB Destination. This acquisition is a 100 percent Small Business set-aside under NAICS code 811121, with a size standard of 9 million dollars. Award will be based on the Lowest-Priced Technically Acceptable (LPTA) solution, evaluating quotes on a strict acceptable or unacceptable basis regarding the Statement of Work. Offerors must be registered in SAM and provide firm-fixed pricing, business size status, and required representations and certifications by September 4, 2026. The contract incorporates various FAR and DFARS clauses, including strict requirements for safeguarding covered defense information, cybersecurity reporting, and prohibitions on certain foreign telecommunications equipment. Funding is contingent upon the availability of appropriated funds beyond October 1, 2026.
Automotive Body, Paint, and Interior Repair and Maintenance

POSTED

about 2 months ago

DEADLINE

in 11 months
View Details
NAICS: 541370
Federal
Fiber Cable Locate and Mapping ServicesThe contract encompasses specialized underground fiber cable locating and mapping services using ground penetrating radar technology to ensure precise identification of subsurface utilities prior to any excavation activities. Compliance with the 811 One-Call system is mandatory, requiring coordination with national utility notification protocols to prevent damage to buried infrastructure and maintain safety standards during construction or development operations. The work is classified under NAICS code 541370, indicating scientific and technical consulting services, and is structured as a subcontract within the Department of Defense’s procurement framework under the FA2823 AFTC PZIO office. Performance of the services is required at a location with a ZIP code of 32542, which is associated with Eglin Air Force Base in Florida, indicating the scope is tied to Defense Department infrastructure projects. The contract was posted on July 10, 2026, and while no solicitation number or set-aside details are provided, the emphasis on technical accuracy and regulatory compliance underscores the critical nature of the work in supporting secure and uninterrupted military communications networks. All activities must adhere to strict protocols for subsurface utility detection to mitigate risks of service disruption, environmental harm, or personnel injury.
Surveying and Mapping (except Geophysical) Services

POSTED

3 months ago

DEADLINE

N/A
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS