W--Negative Wound Pressure

Active
VA25710RI0298Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs North Texas Health Care System (VANTHCS) is seeking rental services for negative pressure wound therapy units to support both inpatient and outpatient care. The contract is initially for one year with four additional one-year options. These units, which must be portable and adaptable to different wound types and patient conditions, are designed to promote wound healing through vacuum-assisted closure and specialized foam dressings that stimulate tissue growth and manage infection and edema. The devices must maintain consistent targeted pressure, include safety alerts for malfunctions, be user-friendly, and ensure patient comfort. The wounds treated may include pressure ulcers, diabetic ulcers, osteomyelitis, surgical dehiscence, and cases involving bariatric patients. Delivery of units is required within two hours of request, with clean, fully functional equipment including all necessary non-disposable accessories. Inspections will be conducted upon delivery, and any issues must be remedied within one hour. Units must be collected within 24 hours after treatment ends, with no charges incurred beyond that notification. Training for VANTHCS staff will be provided shortly after contract award, including initial and annual refresher sessions. Additionally, a qualified negative pressure wound therapy expert must be available around the clock for consultations and assistance with patient assessments to support the facility’s wound care needs. The contract award will prioritize the lowest-priced technically acceptable proposal, and responses must be submitted by interested vendors by the specified deadline.

General Info

Rental contract for portable negative pressure wound therapy units with rapid delivery, training, and expert support.

NAICS

532291 - Home Health Equipment Rental

Place of Performance

TX

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseSources Sought
Posted

Sources Sought

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 257-NETWORK Contract Office 17 (36C257)
ContactsNo contacts available
OfficeSan Antonio, TX, 78240, USA
Office AddressSan Antonio, TX, 78240, USA
ContactsNo contact information available

Full Description

Show more
NEGATIVE PRESSURE WOUND THERAPY UNIT General Requirements: The VA North Texas Health Care System (VANTHCS) located at 4500 S. Lancaster Road Dallas Texas 75216 has a requirement for the rental of negative pressure would therapy units. The length of the requirement is for a base one year period with four one year option periods. The units will be utilized on inpatients and outpatients of the VANTHCS and all units will be required to be delivered to the VANTHCS at the address listed above. Companies capable of providing these services must respond in writing to the attention of the Contracting Officer listed in this announcement (contact@example.gov ) by 12:00 noon, local time, August 23, 2010. Responses must also provide their business size (large, small, 8a, hub-zone, woman-owned small business, service-disabled veteran-owned small business, veteran-owned small business). This announcement is a request for information only; a solicitation will be issued at a later date. Contract award will be made to the offeror who presents the lowest priced technically acceptable proposal. Technical Requirements: Type of Units Required: The medical center primarily requires portable negative pressure wound therapy units. However, the type of unit required may change depending on the type of wound and functional status of the patient who requires wound therapy. Unit Technical Requirements: Negative pressure wound therapy units need to heal wounds by providing negative pressure. This is accomplished by providing a vacuum assisted closure system and a variety of granufoam dressings to create an environment that promotes cellular wound healing through tissue granulation. This is accomplished through forces known as macrostrain and microstrain. Macrostrain is the stretching of the tissue when negative pressure contracts the foam dressing. Microstrain is a deformation at a cellular level, which stretches the cells. This therapy promotes wound healing by removing infectious exudates, decreases edema, promoting moist wound environment that provides tissue profusion and cellular migration and proliferation. The product must maintain targeted pressure at the wound site consistently. This product should be comfortable for the patient/resident. The system should have safety features to include the capability of alerting the staff if blockage, inconsistent pressure, or any other situation that could cause harm to the patient/resident occurs. There should be trouble shooting capabilities and the equipment should be easy to use and maintain (i.e. decreased sound through adequate dressing seal, false alarms). Wound Types: The types of wounds to be treated utilizing the negative pressure wound therapies include but may not be limited to: " Staged pressure areas with measureable depth " Diabetic ulcers " Osteomyelitis " Wounds that have dehisced on abdomen, chest, etc. " Bariatric patients/residents Delivery & Pick-up: Negative pressure wound therapies shall be delivered to the medical center within two hours of request from the medical center. A list of VA ordering officials who may place orders for negative pressure wound therapy units will be provided to the contractor after award of this contract. The VA ordering official will indicate where within the medical center the negative pressure wound therapy unit will need to be delivered. All units delivered to the VANTHCS shall be clean and free of any debris. Units shall be in proper working order with all non-disposable parts and accessories included. Wires should not be frayed. Upon delivery of units VA staff accepting the units will inspect the units to ensure the unit is clean, all necessary non-disposable parts and accessories for use are included, and the unit is in proper working condition. If VA staff determine through inspection that a unit is not fit or safe for patient use the VA ordering official will notify the contractor of the issue and the contractor will be required to correct the issue within one hour of notification of the issue. When wound therapy has been discontinued on a patient one of the identified VA ordering officials will notify the contractor that the negative pressure wound therapy unit needs to be picked up. Charges for the negative pressure wound therapy unit should not be accrued beyond the time of the call notifying the contractor to pick-up the unit. All units should be removed from the VANTHCS within 24 hours of the contractor receiving notification that the unit is no longer required. Education/In-Services and Consultations: Initial training on the negative pressure wound therapy units shall be provided to VANTHCS designated staff within 10 calendar days of contract award. Multiple sessions will be required to ensure all staff who utilize the negative pressure would therapy units receive training. Refresher training will be required annually for VA staff on the anniversary date of the contract and as request by VA. Additionally, the contractor shall provide a negative pressure wound therapy "expert" who is available for consultations with VA staff. The "expert" should be able to assist with assessments and should be available 24 hours a day, 7 days a week, 365 days a year.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Veterans Affairs → 257-NETWORK Contract Office 17 (36C257)

Same awarding agency

NAICS: 238220
New
Federal
Replace Fisher House 1 HVAC System
Solicitation # 36C25726Q0864
Solicitation 36C25726Q0864 was issued by the Department of Veterans Affairs, Network Contract Office 17, for the replacement and upgrade of the HVAC system at Fisher House 1 in San Antonio, Texas. The scope of work included the removal and replacement of three outdoor condenser units and three air handler units, along with associated ductwork, refrigerant piping, and wall controls, and the demolition of the existing boiler system. The project required a Level 3 Infection Control Risk Assessment and the implementation of individual bedroom thermostats. This procurement was designated as a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses, with an estimated contract magnitude between 250,000 and 500,000 dollars. The government intended to award the contract using a Lowest Price Technically Acceptable process, requiring offerors to submit a two-volume proposal consisting of a price schedule and administrative certifications. Key requirements included the provision of performance and payment bonds, adherence to the Davis-Bacon Act, and the submission of a Contractor Quality Control Plan. However, the government has since determined that changes to the requirement are necessary and has canceled the solicitation in its entirety, reserving the right to resolicit the requirement at a later date.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 13 hours ago

DEADLINE

in 1 day
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS