Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on April 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

W065--Tower and Scope Lease, Onsite Endoscopy Specialist, PM and Repair

Closed
36C24626Q0530Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Richmond VAMC 1201 Broad Rock Blvd, Richmond, VA, 23249, USA

Set-Aside

NONE

Documents

1

Sources Sought 36C24626Q0530 Tower and Scope Lease Endoscopy

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)
Contacts1 person available
OfficeHAMPTON, VA, 23667, USA
Office AddressHAMPTON, VA, 23667, USA
Contacts
Stephen NassanContracting Specialist

Full Description

Show more
This Sources Sought Notice is for the Richmond VAMC to determine sources for Tower and Scope Lease, Onsite Endoscopy Specialist, PM and Repair listed as the following: 9 or more units of - 4K/ICG/3D compatible Video Systems 2 or more units of - Video Mediastinascopes 2 or more units of - 4K/3D Exscope System 1 or more units of Service plan for the 13 units 2 units of Onsite specialist for the 13 or more units
Salient Characteristics are as follows: System Functions & Performance Configuration & Integration: Supports multiple configuration options for various operating room (OR) layouts. Modular and expandable components for future upgrades. Integrates with VA IT systems (such as VistA or Cerner) and platforms like StreamConnect. Interfaces with a broad range of endoscopic and surgical devices. Scopes, cameras, and instruments are interchangeable and cross-compatible with tower and software. Stability & Ergonomics: Tower arms/supports stably hold up to 66 lbs. Multiple monitor/light mounting points. User interfaces/control panels accessible from standing position; operable with gloved hands. Ergonomic design to reduce staff fatigue. Lightweight cameras ( 350 grams). Cable Management: Integrated system minimizing visible cables to no more than two ( 2). Cables accessible for adjustments/repair within 5 minutes. Hygiene & Safety: Non-porous surfaces, cleanable/disinfectable per CDC/VA standards in under 5 minutes. Built-in locks or safety features to prevent accidental movement/dislodgement. Scopes and surgical instruments are fully compatible with autoclave sterilization (per VA Directive 1116). Imaging & Compatibility: Cameras support HD and 4K video output ( 3840×2160 resolution). Supports 3D/4K exoscopes for neurosurgery/ENT procedures. Camera Control Unit (CCU) backward/forward compatible with all VA camera heads/scopes. Supports rigid, flexible, exoscopic, and disposable scopes for airway, ENT, urology, and more. Imaging enhancement features: Dynamic brightness adjustment. Red contrast enhancement. Near-infrared (NIR) imaging with ICG fluorescence. Narrow-band imaging (NBI). True-color reproduction. Wide field of view. Integrated image/video recording. Secure, VA-compliant data transfer to VA IT platforms (encrypted wireless transfer if required). Durability: Instruments/scopes/accessories compatible with repeated autoclave sterilization. Service & Support On-site technical support (endoscopy specialist/technician) available during standard operating hours (minimally 7:00am 6:00pm). Telephone technical support available 24/7. On-site technician supports training, live troubleshooting, and rapid issue resolution. Replacement equipment (scopes, cameras, instruments) provided within 48 hours of notification. Initial and ongoing training for OR and clinical staff; in-service dates scheduled within 48 hours of request and delivered within seven days. Preventive and corrective maintenance performed by OEM-certified personnel per manufacturer s recommendations. Repairs documented and reported to VA Biomedical Engineering, including service reports/test data. Functionally equivalent loaner system/component provided within 48 hours of system failure. Updates, patching, and technology refreshes per OEM specification, at VA Biomedical Engineering s discretion. Compliance with VA infection control and patient privacy policies. Physical & Dimensional Requirements Designed for mounting to ceiling booms to maximize floor space. Carts/towers fit through standard VA doorways ( 36 wide). Supports all listed scopes/instruments within manufacturer s recommended weight/dimensions. Clinical Compatibility & Special Features Includes video mediastinoscope for thoracic surgery. Supports 4K/3D exoscope system(s) for ENT/neurosurgery. Cross-functional use: towers, cameras, and scopes are interchangeable for Urology, Gastroenterology, General Surgery, ENT, Thoracic Surgery, and selected Neurosurgery. Accessories & Future Upgrades Supports mounting/integration of additional VA-approved OR accessories and add-ons. Allows for future technology upgrades (hardware/software) during service agreement. Compliance & General Provisions All work compliant with VA, OSHA, and facility safety regulations. Equipment compatible with VA security/privacy requirements (HIPAA, VA Handbook 6500). Service staff trained/certified on relevant equipment. All warranty/service agreement terms clearly outlined in proposal/submission.
ADDITIONAL INFORMATION: This is a SOURCES SOUGHT announcement only. The purpose of this notice is to conduct market research and obtain information from qualified businesses. This is not a request for bids, quotes, or proposals. All responsible sources must submit a capability statement addressing their capabilities, capacity, place of manufacture, and location which shall be considered by the agency.   This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.   Interested parties submitting a response to this inquiry must include the following information: Capability statement Name and address of company NAICS Code SAM.gov UEI number Business size (large, small, VOSB, or SDVOSB) Place of manufacture (if the requirement involves supplies) Identify applicable socioeconomic categories and any pertinent information which demonstrates the firm s ability to meet the above requirement An authorized distributor letter if the interested party is not the manufacturer   All responses shall be submitted no later than Sunday, 05/01/2026, by 06:00 PM EST. Responses shall be emailed to: contact@example.gov. When replying, please include Sources Sought 36C24626Q0530 to ensure the email is reviewed in a timely manner.

More opportunities from Department Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)

Same awarding agency

NAICS: 811198
New
Federal
J025--NEW CART MAINTENANCE AND REPAIR
Solicitation # 36C24627Q0057
Solicitation 36C24627Q0057 is a request for quotations from the Department of Veterans Affairs, Network Contracting Office 6, for a base year plus four option year service contract. The contract requires a provider to perform preventive maintenance, inspection, troubleshooting, and repair services for a fleet of 39 government-owned golf carts and utility vehicles at the Hampton VA Medical Center in Virginia. Services may be performed on-site or at the contractor's off-site facility, with routine work conducted during standard business hours. The contractor is responsible for providing all necessary personnel, tools, and diagnostic equipment to ensure the fleet remains safe and reliable in accordance with manufacturer recommendations. This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The government intends to make a single award based on technical acceptability and the lowest total evaluated price. Following Amendment 0002, the response deadline has been extended to October 29, 2026, at 10:00 AM Eastern Time. Quotations must include a signed Standard Form 1449, pricing on company letterhead, and a signed certificate of compliance regarding limitations on subcontracting per VAAR 852.219-75. Performance will be evaluated through service report reviews, vehicle inspections, and the timely completion of scheduled maintenance.
All Other Automotive Repair and Maintenance

POSTED

about 9 hours ago

DEADLINE

in about 15 hours
View Details
NAICS: 811210
New
Federal
2-WAY RADIO MAINTENANCE FOR SALISBURY NETWORK
Solicitation # 36C24627Q0055
Solicitation 36C24627Q0055 is a total small business set-aside for the Department of Veterans Affairs to obtain inspection, maintenance, and repair services for the two-way radio system (call letters KAO-497) serving the Salisbury VA Medical Center and the Charlotte and Kernersville Health Care Centers in North Carolina. The scope of work includes upgrading the current system to Motorola Capacity Max, providing three FB-type exclusive channels for wide area coverage, and maintaining NC state law enforcement and medical VIPER frequencies. The contractor must adhere to a strict emergency response protocol, requiring a phone response within one hour and on-site arrival within four hours, 24/7/365. The contract is structured with a base year from January 1, 2027, through December 31, 2027, and four subsequent option years, with a total performance period ending December 31, 2031. Award will be based on a best value determination considering technical capability, past performance, and price, following Simplified Acquisition Procedures. Technical requirements include maintaining detailed maintenance and pager logs and complying with OSHA Bloodborne Pathogens Standards. Invoicing is handled monthly in arrears via the VA Electronic Invoice Presentment and Payment System. Quotes must be submitted to Amy Balicat by the specified deadline and include a technical proposal, past performance references from the last five years, and a separate price schedule.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 9 hours ago

DEADLINE

in 18 days
View Details
NAICS: 236220
New
Federal
Z1DA--RENOVATE WARDS 3 EAST & 3 WEST
Solicitation # 36C24627Q0105
The Department of Veterans Affairs, Network Contracting Office 6, is conducting market research via a Sources Sought Notice to identify qualified contractors for the renovation of Wards 3 East and 3 West in Building 47 at the Charles George VA Medical Center in Asheville, North Carolina. This planning effort seeks to determine the best procurement strategy and potential set-aside status for a future one-time Firm-Fixed Price contract with a magnitude exceeding 10 million dollars. The project falls under NAICS code 236220 and involves comprehensive demolition and renovation, including structural work, the upgrade of architectural, mechanical, electrical, plumbing, fire protection, and telecom systems, and the abatement of lead-based paint and asbestos. Qualified respondents must demonstrate the ability to implement ICRA measures, infection control barriers, and construction safety enclosures while complying with VA, Federal, State, NFPA, and Life Safety codes. Key requirements include providing an on-site OSHA Competent Person, ensuring all personnel have OSHA 10/30 certification, and utilizing certified installers for firestopping. Interested firms must submit a capability statement of no more than 10 pages by November 12, 2026, detailing their socioeconomic status, bonding capacity, safety programs, and relevant healthcare renovation experience from the last five years. Registration in the System for Award Management and the VetCert database is required for applicable entities.
Commercial and Institutional Building Construction

POSTED

about 9 hours ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS