Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

Wastewater Treatment Plant Upgrade

Forecast
8640-110State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Wastewater Treatment Plant Upgrade project, identified by solicitation number 8640-110, is funded by the State Water Resources Control Board Division of Financial Assistance and carried out by the Stallion Springs Community Services District in Kern County, California. The primary objective of the project is to ensure compliance with Time Schedule Order R5-2020-0901 regarding final effluent limitations for total ammonia and pH. The scope of work includes evaluating, designing, and developing the necessary documentation to monitor ammonia and pH levels, implement control alternatives, and either construct new treatment controls or modify existing treatment processes. The project is classified as a forecast under NAICS code 221320 and is located at 27800 Stallion Springs Drive, Stallion Springs, CA 93561. It has been determined exempt from the California Environmental Quality Act under Class 6 for information collection and feasibility and planning studies, as the activities are not expected to significantly impact water quality. Key administrative contacts include General Manager Laura Lynne Wyatt and Environmental Scientist Matthew Metelitz. Funding for the project was approved on January 7, 2026.

General Info

Stallion Springs CSD wastewater plant upgrade for ammonia and pH compliance in Kern County.

Agency

California → SWRCB, Division of Financial Assistance

Place of Performance

27800 Stallion Springs Drive, CA, 93561

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseForecast
Posted

forecast

Prepare for this forecast

Research the agency, track this forecast, and prepare your capture plan before the solicitation opens.

Organization & Contact Information

Show more
AgencyCalifornia → SWRCB, Division of Financial Assistance
Contacts2 people available
OfficeN/A
Organization / Agency
California → SWRCB, Division of Financial Assistance
Office AddressN/A
Contacts
Laura Lynne WyattGeneral Manager
Matthew MetelitzEnvironmental Scientist

Full Description

Show more
The State Water Resources Control Board (State Water Board) is a Responsible Agency for the Project. The State Water Board is funding the Project referred to internally as Wastewater Treatment Plant Upgrade. The project will evaluate, design, and develop documents necessary to address the District’s Time Schedule Order R5-2020-0901, for compliance with final effluent limitations for total ammonia and pH. The Time Schedule Order requires the District to monitor and evaluate ammonia and pH in effluent, develop and implement alternatives for total ammonia and pH control, and construct new treatment controls and/or modify the existing treatment process.

Similar Contracts

Same NAICS industry code

NAICS: 221320
New
SLED
Odor and Corrosion Control
Solicitation # 2027-006-JS
The City of Sarasota is soliciting bids for Odor and Corrosion Control services to reduce wastewater odors at multiple lift station facilities. The scope of work includes the operation, maintenance, and repair of these systems, as well as responding to odor complaints within two hours and equipment failures within four hours on a 24/7 basis. Key deliverables include monthly monitoring of all sites and the implementation of a service program that records hydrogen sulfide data at least every five minutes. Bidders must be licensed Florida General Contractors and provide all necessary personnel, materials, and transportation. The contract follows a default term of three years with two optional one-year renewals, for a total potential duration of five years. Award will be granted to the lowest responsible and responsive bidder. Requirements for the contractor include providing new, standard production models of equipment, ensuring all storage tanks are properly labeled according to local, state, and federal regulations, and maintaining insurance with an A.M. Best rating of at least A Excellent. All responses must be submitted electronically as a consolidated PDF via the city's online portal by the December 3, 2026, deadline. Invoicing must include the contract number, purchase order, and Federal Employer Identification Number, with payments issued upon delivery and acceptance of goods or services.
Utilities

POSTED

5 days ago

DEADLINE

in 24 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Prepare for this forecast

Research this forecast and prepare for the solicitation

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS