Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 1, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

White City, Oregon VAMC - Ice Machine, including Condenser, Ice Bin, & Installation

Closed
36C260-24-AP-2277Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

312113 - Ice Manufacturing

Place of Performance

White City, OR, 97503, USA

Set-Aside

SDVOSBC

Documents

2

White City Oregon VA Remote - Salient Characteristics

PDF, High priority: read this first2 pages · specifications
High

Sources Sought: Ice Machine, Condenser, Ice Bin & Installation - VA SORCC

PDF, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Subrina Cantil

Full Description

Show more
Ice Machine, including Condenser, Ice Bin, & Installation, VA Southern Oregon Rehabilitation Center & Clinics Health Center - White City, Oregon (VA SORCC) Veterans Affairs THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method and any possible socio-economic set-aside. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following supply items: Title: Ice Machine Salient Characteristics: Delivery Location: VA SORCC Bldg. 225A Warehouse, 8495 Crater Lake Hwy. White City, OR. 97503 MUST HAVE ACCESSORIES OR OPTIONS: Ice Maker Brazed Line Sets. Must have: Condenser. b. Tubing Kit. Must have: Ice Bin. c. Universal Top Kit Must have: Installation. INSTALLATION INFORMATION: Must provide installation of new equipment. Must provide installation of condenser on top of Ice Bin. Must provide removal of current equipment. Ice Machine Must allow 24 clearance in both front and rear for proper air circulation and ease of maintenance/service. Condenser should not be: Ice Maker water supply line: Minimum 3/8 Nominal ID Copper Water Tubing or Equivalent Ice Maker Drain Line: Minimum Nominal ID Hard Pipe or Equivalent Remote Condenser May be installed outdoors up to 55 from icemaker using a pre-charged tubing kit. Must be 208-230V/60/1 (Connection to Icemaker), 208-230/60/3 (Connection to Icemaker). Ice Bin Must be FPT Drain. DIMENSIONS: Ice Machine: Must be Width: 30 Must be Depth: 24 Must be Height: 32 7/8 Remote Condenser: Must be Width: 62 Must be Depth: 21 Must be Height: 45 Must be Shipping Weight: 345 lbs. Ice Bin: Must be Width: 48 Must be Depth: 41 Must be Height: 60 3/16 Must be Shipping Weight: 315 lbs. MAINTENANCE NEEDS: Must have Certified trained product line maintenance facility within 20 miles installation site. Icemaker: Must have three years: parts and labor warranty on the entire machine. Must have five years: parts and labor warranty on evaporator. Must have panels that are easily removed and all components accessible for service. Remote Condenser: Must have three years: Parts & Labor on entire unit. Must have five years: Parts on: air-cooled condenser coil. Must have five years: Parts on; compressor. Ice Bin: Must have five years: Parts & Labor PERFORMANCE REQUIREMENTS: Must have compatible ice storage bin. Must have compatible remote condenser. Ice Machine Must have individual crescent cube. Must have Stainless Steel Evaporator. Must have Cycle Saver design. Must have up to 1938 lbs. of ice production per 24 hrs. Must have durable stainless-steel exterior. Must be Protected by H-Guard Plus Antimicrobial Agent. Must have EverCheck alert system. Must have no heat, less noise. Must have CFC/HFC free foam. Must have Operating Limits: Ambient Temp Range 45 - 100'F, Water Temp Range 45-90'F, Water Pressure 10-113 PSIG. Remote Condenser Must have Quiet operation. Must be Improved efficiency: Energy saving. Must be Weather resistant cabinet. Must have Refrigerant Charge Amount: 7.1 oz. Must have net weight: 171 lbs. Must have ship weight: 206 lbs. Must have Operating Limits: Ambient Temp Range -20 - 122'F Ice Bin Must have ice storage capacity from 1148 lbs. to 1605 lbs. Must be easy cleaning. Must have foamed-in-place polyurethane insulation, in all bin walls and bottom, providing maximum ice preservation. Must have Baffle design for increased ice accessibility. Must have View windows for inspection and thermal break. Must have Pouch style insulated door for limited condensation while providing maximum access and minimal spillage. Must have 6 adjustable stainless-steel legs. Must be Cubic Volume: 36.9 fl. POWER NEEDS Icemaker: Must have Voltage range: 187-253V. Remote Condenser: Must have Voltage range: 187-253V. MATERIAL AND COLOR: Ice maker: Must have Stainless-steel exterior construction. Must be Protected by H-Guard Plus Antimicrobial Agent. Remote Condenser: Must have weather resistant cabinet. Ice Bin: Must be protected by H-Guard Plus Antimicrobial Agent. Must have seamless polyethylene bin liner. See image on last page. Location: VA SORCC Bldg. 225A Warehouse, 8495 Crater Lake Hwy. White City, OR. 97503 Salient Characteristics have been included in this notice. The Government is accepting industry comment on the notice. Comments may or may not be incorporated, at the discretion of the Government. Potential candidates having the capabilities necessary to provide the above stated supply items are invited to respond to this Sources Sought Notice via e-mail to Subrina Cantil at contact@example.gov no later than Tuesday, 7 May 2024 at 3PM PST. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company name Address Business size Unique Entity ID Number Point of contact name Phone number E-mail address If the services are available on a current GSA Federal Supply Schedule contract. NAICS Code 312113 with a size standard of 750 Employees is applicable to this requirement. Any questions or concerns may also be directed to Subrina Cantil via e-mail. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

about 19 hours ago

DEADLINE

in 6 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

about 19 hours ago

DEADLINE

in 13 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 19 hours ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS