Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on November 23, 2004. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Y -- DESIGN BUILD TEST & EVALUATION COMPLEX

Closed
AI-TSB-TANKS-00001-CC-05Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
F-15EX 8-Bay Maintenance Hangar Complex-Industry Day
Solicitation # W50S8527H1CU0
The National Guard Bureau is seeking market intelligence for the construction of an aircraft maintenance hangar complex at Selfridge Air National Guard Base in Harrison Township, Michigan. This project supports 21 Primary Aircraft Authorization F-15 EX aircraft and is estimated to have a magnitude between 150 million and 200 million dollars. The scope includes the demolition of buildings 3, 5, 117, and 120, with new parking constructed in the footprints of buildings 117 and 120. The construction may be executed in three phases: Hangar 1, a 2-bay corrosion control and fuel cell hangar; Hangar 2, a 4-bay maintenance hangar; and Hangar 6, a 2-bay munitions and training facility. The project also requires necessary utility and infrastructure upgrades. The government is considering a fixed-price agreement utilizing an Other Transaction Agreement under the authority of 10 U.S.C. 2808a, with funding potentially provided in annual phases of approximately one-third of the total cost. Technical requirements include compliance with DoD antiterrorism and force protection standards, adherence to Air Force and base design standards, and specialized foundations to meet flood plain requirements. Design is anticipated to be 100 percent complete by early 2027. This notice is for planning purposes only and is not a formal solicitation. Interested firms under NAICS code 236210 must provide company details, bonding capacity, and evidence of experience with aviation facilities and constrained-site construction to the designated points of contact by the response deadline of December 1, 2026.
W7NF Uspfo Activity Miang 127

POSTED

2 days ago

DEADLINE

in about 1 month
NAICS: 236210
New
SLED
Facilities & Parks New Supply Warehouse Building
Solicitation # ITB FM 04-27
The Board of County Commissioners of Okaloosa County, Florida, is soliciting bids under ITB FM 04-27 for the construction of a new 9,000 square foot metal supply warehouse for the Facilities and Parks Department located at 5489 Old Bethel Road in Crestview. The project involves comprehensive site preparation and construction, including the installation of energy-efficient HVAC systems, electrical and plumbing work, and telecommunications wiring. All work must comply with the 2023 8th Edition Florida Building Code, ADA standards, and OSHA regulations, with specific structural requirements to withstand 160 MPH ultimate wind speeds. A fire alarm system is explicitly not required for this project. Bids must be submitted electronically via OpenGov by November 4, 2026, at 3:00 pm CST. The contract will be awarded to the responsive and responsible vendor with the lowest bid, though the County reserves the right to negotiate the most advantageous agreement. The selected contractor must provide a dedicated project manager and furnish both bid and performance bonds. The project timeline is 12 months from the notice to proceed. Payment will be processed through the County Finance Office in accordance with the State of Florida Local Government Prompt Payment Act, contingent upon annual appropriation. For projects involving federal grant funding, contractors must be registered in SAM.gov and comply with Buy America and Trafficking Victims Protection Act requirements.
Facilities & Parks

POSTED

7 days ago

DEADLINE

in 5 days

AI Contract Overview

Show more

Bechtel Nevada is seeking pre-qualified general contractors for the design and construction of a Test and Evaluation Complex at the Nevada Test Site, Area 6, in Mercury, Nevada. The scope of work includes a 6,500 square foot pre-engineered metal building featuring a 10 ton bridge crane, specialized foundation pits, and a remote-operated vehicle puller system, as well as a 4,000 square foot modular office building with a secure, soundproofed conference room. Additionally, the project requires the installation of two 150,000 gallon welded steel fire water storage tanks and two pump houses, one for potable water and one skid-mounted system for fire water. Certain components of the project are designated as Safety Significant and are subject to the Price Anderson Act Amendment. All successful subcontractors must be signatories to the Bechtel Nevada Project Labor Agreement for Construction. Interested parties must submit pre-qualification documentation by December 15, 2004, including architect-engineering qualifications, safety records with a focus on EMR rates, a quality assurance program, evidence of at least five years of similar project experience, and resumes for key management and engineering personnel.

General Info

Bechtel Nevada seeks pre-qualified contractors for a Test and Evaluation Complex in Nevada.

Agency

N/A

NAICS

236210 - Industrial Building Construction

Place of Performance

Nevada Test Site, Area 6Nye County, Nevada on Federal land controlled by the National Nuclear Security Admininstration (NNSA) 8

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Bechtel Nevada is seeking General Contractor sources that can provide for the design and construction of the following at the Nevada Test Site, Area 6, Mercury, Nevada. [A] One pre-engineered metal building 65 feet by 100 feet in plan with 34 foot eve height. Two rollup doors - one 18 feet by 18 feet and one 10 feet by 10 feet at a loading dock. To include one maintenance work room inside the main building at 18 feet by 26 feet, two rest rooms, pad mounted HVAC for full building (four units envisioned), electrical power, lighting, fire sprinkler and alarm systems. Also to include a 10 Ton bridge crane across the 65 foot span. Foundation will require one special pit 10 feet wide, 33 feet long and 12 feet deep with electrical power and conduits for communication run to the pit. Another pit will be 6 feet by 14 feet and 3 feet deep also requiring electrical and communications underground. The central area of the slab will require flush wide-flange steel surface embeds for attachment of user devices. The pathway between the two main rollup doors (and extending outside at one end) is to have a floor mounted vehicle puller mechanism (car wash style) to pull a tractor-trailer through the 100 foot axis of the building by remote operation. [B] One modular office building to include HVAC, lighting, power, fire protection and alarm. 4000 square feet expected. To include one communications equipment room, one control room with raised computer floor (electronics by others), three offices, three work rooms with benches for electronics repairs, two rest rooms and one Secure Limited Conference room requiring soundproofing and other special treatment to facilitate classified discussions. [C] One 150,000 gallon Fire Water, Welded Steel, Storage Tank, 16 feet in height. The tank will be designed and constructed in accordance with AWWA Standard for Welded Steel Tanks for Water Storage D100-96. All items pertaining to this subcontract are of Commercial Designation, (CM). [D] One potable water pump house. The requirements are for 2 sets of pumps. One set is for a potable water distribution system at wit a supply of 20 gpm @ 60 psi discharge and one set of pumps for a Fire Water Storage Tank makeup rated at 315 gpm at 90 psi discharge. Pumps will be fed from a potable water storage tank. Piping for the pumps must conform to the Nevada Administrative Code 445A - Water Controls. All items pertaining to this subcontract are of Commercial Designation, (CM). All items pertaining to this subcontract are subject to the Price Anderson Act Amendment (PAAA) are designated as Safety Significant (SS). [E] One 150,000 gallon Fire Water, Welded Steel, Storage Tank, 16 feet in height. The tank will be designed and constructed in accordance with NFPA 22, Standard for Water Tanks for Private Fire Protection. All items pertaining to this subcontract are subject to the Price Anderson Act Amendment (PAAA) are designated as Safety Significant (SS). [F] One prefabricated, skid mounted, fire water pump house. The system shall be designed in accordance with NFPA 20. Pumps should be selected to deliver 1250 gpm at 90 Psig. All items pertaining to this subcontract are subject to the Price Anderson Act Amendment (PAAA) are designated as Safety Significant (SS). ***Any resultant subcontract will require the contractor to be signatory to Bechtel Nevada Project Labor Agreement for Construction. This agreement can be found at the following site: http://www.bechtelnevada.com/ppmgt/const_main.htm*** It is anticipated the formal Request for Proposal package will be issued in January 2005 to pre-qualified sources. INTERESTED PARTIES WISHING TO PRE-QUALIFY FOR RECEIPT OF A PROPOSAL PACKAGE WILL BE EVALUATED BY SUPPLYING THE FOLLOWING INFORMATION IN ACCORDANCE WITH THE BELOW LISTED EVALUATION CRITERIA NO LATER THAN DECEMBER 15, 2004. Pre-Qualification Evaluation Criteria: 1. Design Capabilities: Provide a complete Standard Form 330, - Architect-Engineering Qualifications which identifies company qualifications demonstrating capabilities to fulfill the requirement identified in the description above. 2. Safety Experience: The proposer must demonstrate the effectiveness of its Safety and Health programs by providing a copy of their program. In addition a 36 month OSHA violation and accident history (or the history this company has available); its 36 month MSHA violation and accident history (or the history this company has available); the MSHA Total Incident Rate. The evaluation will focus on the Offeror's Interstate Experience Modification Rate (EMR) for the three most recent years and the use of the Offeror's OSHA and MSHA history for the last three reported years. An EMR rate greater than one may be cause for rejection. 3. QA/QC Program: The proposer must submit an implemented Quality Assurance Program commensurate with the scope of the activities for the required work to meet the requirements of DOE Order 414.1A. 4. Company Experience/Past Performance: Proposer and any lower'tier subcontractors (if applicable) shall have a minimum of five (5) years experience and shall demonstrate company experience in projects similar to this requirement. Provide number of years the company has been in business and similar projects current and within the past 5 years. Past Performance information shall include project description, dollar magnitude, completion date (if the date was extended the circumstances), contract number, and point of contact information. 5. Key Personnel: Provide a listing of key personnel with functional responsibilities which adequately addresses the disciplines as described in the requirement. Submit resumes for the management team (Project Manager/Superintendent), Design Engineers, and Safety Representatives. Identify whether certifications are currently held by the proposed staff or must be obtained, i.e., Nevada registered Engineers, etc.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS