Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on March 25, 2010. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Y--Upgrade Elevators in the Community Living Center @ Bronx

Awarded
VA-243-10-IB-0169Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation (MTC) is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The scope of work includes conducting site surveys to verify door dimensions and fire ratings, procuring Grade I heavy-duty panic bars, exterior trim, rim cylinders, strikes, and door closers, and performing installation and testing. All work must adhere to NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and ADA standards. To ensure fail-safe operation, contractors must perform at least 10 consecutive cycle tests on all installed hardware. This is a fee-for-service subcontracting opportunity open to small businesses, including certified VOSB, SDVOSB, WOSB, and HUBZone entities under NAICS code 238290. Bidders must be licensed in the State of Idaho and provide three references for similar projects. Required submission documents include a completed bid sheet with lump sum and individual deficiency pricing, a W-9, a self-certification form, and acceptance of terms and conditions. All bids must be submitted via email to Sandra Clore by December 1, 2026, at 3:00pm MST. The contract is subject to various federal regulations, including the Davis-Bacon Act for prevailing wage rates and fringe benefits, as well as FAR clauses regarding Buy American preferences and combating trafficking in persons. Contractors are required to comply with DOL records management, mandatory training, and privacy breach notification requirements. Payment will be issued upon the submission of invoices for materials and services that have been delivered and accepted by MTC. Final inspection and acceptance will occur at the MTC designated point of delivery.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
Pauma Security Gate
Solicitation # 2026-27-06
Solicitation 2026-27-06 for the Valley Center Pauma Unified School District involves the fabrication and installation of automated, keypad-entry hinging steel security swing gates at entry and egress driveways in Valley Center, California. The project requires two powder-coated steel double swing gates, each 18 feet wide by 5 feet tall, and explicitly prohibits the use of chain link options. Key technical components include a mounted Knox switch with Fire Department filing, two entry remotes, gate hold timers, a mounted strobe detector for emergency vehicles, and a keypad similar to the Door King 1506-086. The contract value is capped at 1,000,000 dollars, and the award will be granted to the lowest responsive and responsible bidder. Eligible bidders must hold a California contractor's license C13 or C-61/D28 and comply with prevailing wage requirements and Department of Industrial Relations registration. The project mandates a payment bond for 100 percent of the total bid price and a DVBE participation goal of at least 3 percent. Required submissions include a comprehensive bid packet featuring non-collusion affidavits, Iran Contracting Act certification, and fingerprinting certifications. Performance must be coordinated with the Director of Maintenance and Operations, with work hours restricted to 7:00 am to 5:00 pm, Monday through Friday. Additionally, contractors must adhere to strict hazardous material standards and California Air Resources Board compliance, with the district maintaining the right to terminate the agreement upon 30 calendar days written notice.
Valley Center Pauma USD

POSTED

about 21 hours ago

DEADLINE

in 4 days

AI Contract Overview

Show more

Project No. 526-09-114 involves the upgrade of elevators P-1, P-2, and P-3 at the Community Living Center within the James J. Peters VA Medical Center in Bronx, New York. This project is a Service Disabled Veteran Owned Small Business Set-Aside under NAICS code 238290, with an estimated cost between 500,000 and 1,000,000 dollars. The scope of work includes selective demolition, elevator renovations, minor interior finishes, and electrical repairs to the existing generator. Technical requirements focus on replacing pistons and cylinders with ASME/ANSI A17.1 2000 compliant components, installing new motors, controllers, and elevator cabs, and updating various signaling and safety devices. Existing capacity, speed, travel distance, and structural frames will be retained. Bidders must be registered in required government databases and submit hardcopy bids, as electronic submissions are not accepted. Bonding is required for this project.

General Info

Upgrade elevators P-1, P-2, P-3 at James J. Peters VA Medical Center, Bronx.

Agency

N/A

Contract Value

$688,400

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

NY, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

Response deadline changed from Feb 8, 2010 to Mar 3, 2010. The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
This notice is for project No. 526-09-114, Upgrade Elevator in the Community Living Center at James J. Peters VA Medical Center, 130 West Kingsbridge Road, Bronx, NY 10468-3904. This shall be a Service Disabled Veteran Owned Small Business Set-Aside (SDVOSB). As a result all SDVOSB's may submit a bid, which shall be considered by the agency. This project is classified under NAICS code 238290, and has a size standard of $14.0 Million. The cost estimate for this project is between $500,000.00 and $1,000,000.00. The work for this requirement consists of, but is not limited to selective demolition, elevator renovations, minor interior finishes, and electrical work. The elevator work includes remodeling of elevators P-1, P-2 and P-3. The new elevator work includes the removal of the existing pistons and cylinders and replacing with new pistons and PVC sealed cylinder protection with double bottom cylinder, cylinder protection plates, pressurization ports, evacuation ports, plunger stops, safety bulkhead evacuation tube and PVC end cap, that complies with ASME/ANSI A17.1 2000 code. The elevators to have new soft starters, motors, power unit, mufflers, valves, automatic self leveling, controllers, integral car operating panels, audible signal, car position indicators, "in Car" Directional lanterns, emergency car lighting, hall buttons, hall lanterns, hall position indicators, door operators, interlocks, Lambda 3d protection devices, car door hangers hoist way, door hangers, and new elevator cabs. The following elevator components will be retained; Existing capacity and travel distance, elevator speed, existing openings and stops will remain, power supply will stay the same. Car rails, car guides, care frame and platform frame will all remain. Electrical work will include repairs to the existing generator problems. All other details and information shall be contained in the solicitation which shall be posted on www.fedbizopps.gov. The solicitation will be released on or around February 8, 2010. The bid submittal address, date and time will be included in the solicitation. This project requires bonding and all bid submission shall be in hardcopies; faxed or e-mailed bids will not be accepted. All bidders shall be registered in www.ccr.gov, www.vetbiz.gov, www.orca.bpn.gov, and http://vets100.vets.dol.gov. End of Description

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS